For the Cummins/Onan C2750 D5 / QSK60, from the Cummins/Onan operator's manual.

Applies to: Cummins/Onan C2750 D5, Cummins/Onan DQKAN, Cummins/Onan QSK60, Cummins/Onan QSK60 engine, Cummins/Onan QSK60-G19 engine, Cummins/Onan QSK60-G22 engine

Before you start

  • Accidental or remote starting can cause severe personal injury or death.

Procedure

  1. Press the Off mode switch on the operator panel to shut down the generator set.
  2. Press the Emergency Stop button to prevent starting from any source.
  3. Thoroughly ventilate the plant room before disconnecting any leads.
  4. Isolate and lock off the supply to the heater, where fitted.
  5. Isolate and lock off the supply to the battery charger, where fitted.
  6. Isolate the fuel supply to the engine.
  7. Using an insulated wrench, disconnect the negative (–) battery cable first.
  8. Fit warning notices to indicate Maintenance in Progress – Plant Immobilized.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Cummins/Onan C2750 D5 →, Cummins/Onan DQKAN →, Cummins/Onan QSK60 →

Source: Cummins/Onan operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.