Home›Repair guides›Cummins/Onan›Battery Cable Check

Cummins/Onan — Battery Cable Check

Testing & diagnosis · Battery cables

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan MDKC, Cummins/Onan MDKD, Cummins/Onan RGA-OP'

Procedure

  1. With starter motor operating, check voltage drop from battery negative post to cylinder block.
  2. Check voltage drop from battery positive post to battery terminal stud on solenoid.
  3. Each should normally be less than 0.3 volts.
  4. Clean all connections in any part of the circuit showing excessive voltage drop.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Each voltage drop less than 0.3 volts.

Full service-parts list: Cummins/Onan MDKC →, Cummins/Onan MDKD →, Cummins/Onan RGA-OP' →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →