Service parts for the 3508
Grouped by system, with how many of each the parts manual calls for.
Air intake
1 requiredFuel system
1 requiredOil system
1 requiredBelts
1 requiredCooling system
1 requiredElectrical
1 requiredHydraulic system
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 620 kW |
| Prime power | 485 kW |
| Emissions | Tier 1, Stage I |
| Controller | ADEM A3 |
| Oil capacity | 104.0 L |
| Alternator | SR4 |
| Voltage options | 600 V |
| Phase | 3 phase |
| Rated current | 962 A |
| Power factor | 1 |
| Coolant capacity | 285 L |
| Max ambient | 80 °C |
| Dimensions (L×W×H) | 2136×1703×1720 mm |
| Dry weight | 10136 kg |
Engine
| Oil capacity | 397.0 L |
|---|---|
| Coolant capacity | 103.0 L |
| Displacement | 34.5 L |
| Aspiration | TA |
| Rated speed | 1800 rpm |
Filters for the Caterpillar 3508B
2Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P551808 | Lube Filter, Spin-On Full Flow | CATERPILLAR 1R1808, CATERPILLAR 1R808, NAPA 7792, BALDWIN B7299 | KuduParts $80.00 |
| Fuel filter | P551316 | Fuel Filter, Spin-On | CATERPILLAR 1R0755, CATERPILLAR 3890433, NAPA 3685, BALDWIN BF7639 | KuduParts $54.00 FridayParts $55.99 |
Maintenance & consumables
for the Caterpillar 3508B| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Air filter inner | 106-3973 | Amazon eBay $79.98 eBay $39.31 NAPA $116.29 FridayParts $62.16 | ||
| Fuel filter | Filter fuel | 1R0755 | Amazon eBay $34.99 eBay $96.90 NAPA $82.67 NAPA $82.67 KuduParts $54.00 FridayParts $71.99 | ||
| Oil filter | Filter oil | 1R0716 | Amazon eBay $44.90 eBay $44.90 NAPA $33.79 NAPA $33.79 KuduParts $80.00 FridayParts $81.99 | ||
| Battery | 245-5829 | Amazon eBay $98.00 | |||
| Belt | V-belt | 141-7116 | eBay $31.99 NAPA $16.79 FridayParts $22.60 | ||
| Coolant | 9S-8140 | Amazon eBay | |||
| Hydraulic filter | Filter hydraulic | 1R0741 | eBay $22.00 NAPA $25.37 | ||
| Oil | CF-4 | 644.0 L | — | 1000 hr | |
| Spark plug | — |
Service intervals
40| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| System | Test | 1 hr | ToCI quarterly: exercise system under full load for 1 hour | |
| Battery Electrolyte Level | Check | 250 hr | Every 250 Service Hours | |
| Belts | Inspect | 250 hr | Inspect/Adjust/Replace; Every 250 Service Hours | |
| Cooling System Coolant Sample (Level 1) | Other | 250 hr | Obtain; Every 250 Service Hours | |
| Cooling System Supplemental Coolant Additive (SCA) | Test | 250 hr | Test/Add; Every 250 Service Hours | |
| Engine Oil Sample | Other | 250 hr | Obtain; Every 250 Service Hours | |
| Engine Oil Sample | Test | 250 hr | Every 250 Service Hours - Obtain | |
| Engine Valve Lash | Adjust | 4000 hr | First service — Inspect/Adjust; Initial 250 Service Hours | |
| Fan Drive Bearing | Lubricate | 250 hr | Every 250 Service Hours | |
| Fuel Injector | Adjust | 4000 hr | First service — Inspect/Adjust; Initial 250 Service Hours | |
| Hoses and Clamps | Inspect | 250 hr | Inspect/Replace; Every 250 Service Hours | |
| Radiator | Clean | 250 hr | Every 250 Service Hours | |
| Speed Sensor | Clean | 250 hr | First service — Initial 250 Service Hours (Prime Power) - Clean/Inspect | |
| Air Shutoff | Test | 500 hr | Every 500 Service Hours (Prime Power) | |
| Cooling System Coolant Sample (Level 1) | Test | 500 hr | Every 500 Service Hours (Prime Power) | |
| Cooling System Coolant Sample (Level 2) | Test | 500 hr | First service — Initial 500 Hours for new, refilled and converted systems | |
| Engine Oil and Filter | Change | 500 hr | Every 500 Service Hours - standard sump; deep sump every 1000 hours | |
| Magnetic Pickups | Clean | 500 hr | First service — Clean/Inspect; Initial 500 Service Hours or at first oil change | |
| Cooling System Coolant Sample (Level 2) | Other | 1000 hr | Obtain; Every 1000 Service Hours | |
| Engine | Clean | 1000 hr | Every 1000 Service Hours | |
| Engine Crankcase Breather | Clean | 1000 hr | Every 1000 Service Hours | |
| Engine Protective Devices | Check | 1000 hr | Every 1000 Service Hours | |
| Engine Protective Devices | Test | 1000 hr | Check; Every 1000 Service Hours | |
| Fuel System Primary Filter | Replace | 1000 hr | Every 1000 Service Hours - Clean/Inspect/Replace | |
| Fuel System Secondary Filter | Replace | 1000 hr | Every 1000 Service Hours | |
| Generator Winding Insulation | Test | 1000 hr | Every 1000 Service Hours | |
| Rotating Rectifier | Inspect | 1000 hr | 12 mo | Every 1000 Service Hours or 1 Year - Inspect/Test |
| Crankshaft Vibration Damper | Inspect | 2000 hr | Every 2000 Service Hours | |
| Engine Mounts | Check | 2000 hr | Every 2000 Service Hours | |
| Generator | Other | 2000 hr | 6 mo | Every 2000 Service Hours or 6 Months - Dry |
| Generator Set Vibration | Test | 2000 hr | Every 2000 Service Hours - Test/Record | |
| Stator Lead | Check | 2000 hr | 6 mo | Every 2000 Service Hours or 6 Months |
| Turbocharger | Inspect | 2000 hr | Every 2000 Service Hours | |
| Cooling System Coolant (DEAC) | Change | 3000 hr | 36 mo | Every 3000 Service Hours or 3 Years |
| Cooling System Coolant Extender (ELC) | Other | 3000 hr | 36 mo | Every 3000 Service Hours or 3 Years - Add |
| Air Shutoff Damper | Check | 6000 hr | Every 6000 Service Hours - Remove/Check | |
| Alternator | Inspect | 6000 hr | 72 mo | Every 6000 Service Hours or 6 Years |
| Cooling System Coolant (ELC) | Change | 6000 hr | 72 mo | Every 6000 Service Hours or 6 Years |
| Cooling System Water Temperature Regulator | Replace | 6000 hr | 72 mo | Every 6000 Service Hours or 6 Years |
| Prelube Pump | Inspect | 6000 hr | 72 mo | Every 6000 Service Hours or 6 Years |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
60| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Air shutoff damper plunger distance A (minimum) | 18.3 | mm | 0.72 inch; replace plunger if less |
| Clearance | Coolant level below bottom of filler pipe | 13 | mm | no sight gauge |
| Clearance | Crankshaft end play | .178 to .635 | mm (0.0070 to 0.0250 inch) | measured with dial indicator |
| Clearance | Crankshaft end play after assembly | 0.178 to 0.635 | mm (0.0070 to 0.0250 inch) | after assembly |
| Clearance | End play at heat sink after assembly | 0.076 to 0.635 | mm (0.0030 to 0.0250 inch) | after assembly |
| Clearance | Gap at 3, 6, 9, 12 o'clock positions | 0.03 to 0.13 | mm (0.001 to 0.005 inch) | between |
| Clearance | Gap between generator and flywheel housing at locations (E), (F), (G), (H) | >0.03 and <0.13 | mm (0.001 inch to 0.005 inch) | more than 0.03 mm and less than 0.13 mm |
| Clearance | Generator forward offset from midpoint of end play | + 0.50 | mm (+ 0.0200 inch) | while generator supported by crane |
| Clearance | Rotor end play | 3.81 to 7.62 | mm (.150 to .300 inch) | approximately |
| Clearance | Shim thickness divisor for number of shims | 0.8 | mm (0.03 inch) | divide Letter L by this value |
| Clearance | Support deflection during bolt tightening | 0.13 | mm (0.005 inch) | maximum allowed movement |
| Gap | Air shutoff damper plunger distance A (replace if less) | 18.3 | mm | |
| Other | Air cleaner element cleaning limit | six times | replace at least once per year regardless | |
| Other | Altitude capability without derate | 1525 | m | |
| Other | Altitude capability without derate | 800 | m | |
| Other | Coolant Sample (Level 1) interval for Cat DEAC | 250 | hours | |
| Other | Cooling system cleaner amount (heavy deposits) | 0.5 | L per 3.8 to 7.6 L capacity | 1 pint per 1 to 2 US gal |
| Other | Cooling system cleaner amount (normal deposits) | 0.5 | L per 15 L capacity | 1 pint per 4 US gal |
| Other | Cooling system cleaning duration (heavy deposits) | 90 | minutes | minimum, coolant at least 82 C (180 F) |
| Other | Cooling system cleaning duration (normal deposits) | 30 | minutes | minimum, coolant at least 82 C (180 F) |
| Other | Cooling system fill rate maximum | 19 | L/min | |
| Other | Damper fluid viscosity degradation limit | 20 | percent | majority of applications |
| Other | Damper fluid viscosity degradation limit (Hasse & Wrede) | 20 | percent | majority of applications |
| Other | Damper operating hours before rebuild/replace (damper without sampling port) | 20000 | hours | |
| Other | Damper without sampling port - rebuild/replace interval | 20000 | hours | or at major overhaul |
| Other | Exercise under full load | 1 | hour | ToCI quarterly |
| Other | Fast Acting Cooling System Cleaner amount | 0.5 L per 15 L | L | cooling system capacity, normal deposits |
| Other | Fast Acting Cooling System Cleaner amount | 0.5 L per 3.8 to 7.6 L | L | cooling system capacity, heavy deposits |
| Other | Full load test duration | 4 | hours | Once per year |
| Other | Gross Input Torque (TH55-E70) | 12 667 | N•m (9350 lb-ft) | |
| Other | Gross Input Torque (TH55-E90) | 12 677 | N•m (9350 lb-ft) | |
| Other | Hydrosolv cleaner concentration | 2 to 5 | percent | temperatures up to 93 C (200 F) |
| Other | Load bank data recording interval | 15 | minutes | During load bank test |
| Other | Load bank test load level | 80 | % of generator nameplate capacity | 4-hour resistive load bank test |
| Other | Load bank test profile | 2 hours at 50%, 1 hour at 75%, 1 hour at 100% | Annual four (4) hour load bank test | |
| Other | Maximum air pressure at nozzle for cleaning purposes | 205 | kPa | 30 psi |
| Other | New drive belt tension recheck after operation | 30 | minutes | rated rpm |
| Other | Rating condition (diesel 7 L and higher) | 99 kPa (29.31 in Hg) dry barometer, 25°C (77°F) | SAE J1995 inlet air standard | |
| Other | Rating condition (diesel up to 6.6 L) | 100 kPa (29.5 in Hg) total barometric pressure, 1 kPa (.295 in Hg) vapor pressure, 25°C (77°F) | ISO/TR14396 inlet air standard | |
| Other | Rating condition (gas) | 100 kPa (29.61 in Hg) and 25°C (77°F) | SAE J1349 standard | |
| Other | Stall Torque Ratio (TH55-E70) | 2.23 | ||
| Other | Stall Torque Ratio (TH55-E90) | 2.23 | ||
| Other | Starting motor cool-down between cranking periods | 2 | minutes | |
| Other | Supplemental coolant additive concentration maximum (conventional coolant) | 6 | percent | |
| Other | Supplemental coolant additive concentration maximum (water and SCA) | 8 | percent | |
| Other | Thread lock cure time minimum before air shutoff use | 1 | hour | |
| Pressure | Air cleaner service indicator restriction (clean/replace) | 6 | kPa | 25 inches of H2O |
| Pressure | Engine air cleaner differential pressure (nominal) | 3 | kPa | normal engine operation |
| Pressure | Engine air cleaner maximum differential pressure (replace element) | 6.2 | kPa | |
| Pressure | Engine oil filter differential pressure (nominal) | 60 | kPa | normal engine operation |
| Pressure | Engine oil filter differential pressure (normal) | 60 | kPa | normal engine operation |
| Pressure | Engine oil filter differential pressure (replace elements) | 103 | kPa | oil filter elements to be replaced |
| Pressure | Engine oil pressure during cranking | 70 | kPa | cranking with fuel off |
| Pressure | Fuel filter differential pressure (nominal) | 60 | kPa | normal engine operation |
| Pressure | Fuel filter differential pressure (normal) | 60 | kPa | normal engine operation |
| Pressure | Fuel filter differential pressure (replace secondary elements) | 103 | kPa | fuel filter elements to be replaced |
| Pressure | Maximum air pressure at nozzle for cleaning | 205 | kPa | |
| Pressure | Maximum air pressure for cleaning (aftercooler core) | 205 | kPa | 30 psi; at nozzle |
| Pressure | Maximum air pressure for cleaning (radiator) | 205 | kPa | 30 psi; deadheaded nozzle |
| Pressure | Maximum air pressure for cleaning air cleaner element | 207 | kPa | 30 psi |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | Cat DEAC | Diesel; 3,000 Service Hours or Three Years; annual S·O·SSM Level 2 coolant sampling and analysis | |||
| Coolant | Cat DEAC (Diesel Engine Antifreeze/Coolant) | Conventional coolant; SCA required; see SEBU6251 | |||
| Coolant | Cat ELC | Diesel; 12,000 Service Hours or Six Years; add Cat ELC Extender at 6,000 service hours or one half of service life; annual S·O·SSM Level 2 coolant sampling and analysis | |||
| Coolant | Cat ELC (Extended Life Coolant) | Add Cat ELC Extender once; do not use conventional SCA with Cat ELC | |||
| Coolant | Cat ELC Extender | Needs to be added only once; add per cooling system capacity | |||
| Coolant | Cat NGEC | Natural Gas; 16,000 Service Hours or Three Years; use interval that occurs first | |||
| Coolant | Commercial long life / heavy-duty coolant meeting Caterpillar EC-1 | Caterpillar Engine Coolant Specification -1 (EC-1) | Obtain Level 1 coolant sample | ||
| Coolant | Commercial long life coolant meeting Caterpillar EC-1 | Caterpillar Engine Coolant Specification -1 (EC-1) | |||
| Coolant | Supplemental Coolant Additive (SCA) | Max 6 percent with conventional coolant; max 8 percent with water and SCA | |||
| Engine oil | EPA 2D 89.330-96 (fuel reference, Diesel <6.6 L, density 0,845-0,850 kg/L a 15 °C) | Reference condition only, not a lubricant recommendation | |||
| Engine oil | Cat NGEO | Natural Gas | |||
| Engine oil | air tool oil | below 0°C | Air starting motor lubricator; temperatures below 0 C (32 F) | ||
| Engine oil | low sulfated ash oil | Required for U.S. EPA Tier 4 Final, EU Stage IV engines. | |||
| Engine oil | meeting manufacturer's specs | Add crankcase oil (grade meeting manufacturer's specs) to correct level (SCI) | |||
| Engine oil | Cat Arctic DEO SYN SAE 0W-30 | -40°C to 30°C | Engine Crankcase; Industrial Engines | ||
| Engine oil | Cat DEO SYN SAE 5W-40 | -30°C to 50°C | Engine Crankcase; Industrial Engines | ||
| Engine oil | Cat DEO SAE 10W-30 | -18°C to 40°C | Engine Crankcase; Industrial Engines | ||
| Engine oil | Cat DEO SAE 15W-40 | -9°C to 50°C | Engine Crankcase; Industrial Engines | ||
| Engine oil | nondetergent SAE 10W | above 0°C | Air starting motor lubricator; temperatures greater than 0 C (32 F) | ||
| Fuel | Ultra Low Sulfur Diesel (ULSD) | Contains less than or equal to 15 parts per million sulfur (mg/kg); required for U.S. EPA Tier 4 Final, EU Stage IV engines. B20 biodiesel capability available. | |||
| Fuel | 35° API gravity at 60°F (16°C) | LHV 18,390 Btu/lb (42 780 kJ/kg) | Fuel at 85°F (29°C) weighing 7.001 lbs/U.S. gal (838.9 g/liter) | ||
| Fuel | 35° API gravity, LHV 42 780 kJ/kg (18,390 btu/lb) | SAE J1995 | Diesel engines 7 liter and higher; used at 29°C (84.2°F) with density 838.9 g/L | ||
| Fuel | EPA 2D 89.330-96 | EPA 2D 89.330-96 | Diesel engines up to 6.6 liter; density 0.845-0.850 kg/L @ 15°C (59°F); fuel inlet temperature 40°C (104°F) | ||
| Fuel | No. 2 fuel | 3600 engines designed for 80 000 hours on No. 2 fuel; ratings based on API gravity of 35 at 15 C (60 F), LHV of 42 780 kJ/kg used at 29 C (84 F) with a density of 838.9 g/L | |||
| Fuel | dry natural gas, LHV 35.54 MJ/Nm3 (905 btu/ft3) | Gas ratings based on SAE J1349 standard conditions of 100 kPa (29.61 in Hg) and 25°C (77°F) | |||
| Grease | Cat Generator Set Grease | Part Number 108-8611 | |||
| Grease | EA6 | -40°C to 80°C | Non-regreasable bearings 311-0843/311-0844 | ||
| Grease | Mobilith SHC220 | -40°C to 80°C | 2.8 g | Roller bearings 139-0349/139-0350; every 250 service hours | |
| Grease | 2S-3230 Bearing Lubricant | -29°C to 80°C | 51.2 g | Generator bearings; 59 mL (2 oz); every 2000 service hours or 12 months | |
| Grease | UNIREX N3 | -29°C to 60°C | Do not exceed 60 °C (140 °F) above ambient; some bearings non-regreasable |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Alignment Of Electric Sets With Supports At The Flywheel Housing / Installation Of A New Generator Or Flexible Plates adjustment
Tools: crane, dial indicator, shims, torque wrench
- Loosen all bolts connecting base to foundation; loosen all bolts fastening engine supports and generator supports to base.
- Ensure enough clearance between bolts and bolt holes in base, engine supports, generator supports at all locations.
- Check clearance between base and foundation at all mounting locations; use shims to prevent deflection; tighten base-to-foundation bolts to final torque.
- While generator supported by crane, loosen all bolts (2) fastening generator to flywheel housing; tighten alternate bolts to final torque; check clearance between base and engine and generator support
- Tighten all bolts fastening engine supports and generator supports to base to half of final torque; loosen all bolts (2); measure gap between generator and flywheel housing; ensure bolts centered in c
- Gaps at (E), (F), (G), (H) should be more than 0.03 mm (0.001 inch) and less than 0.13 mm (0.005 inch); adjust shims or move rear of generator right or left.
- After shim correction, tighten generator support bolts to half of final torque 450 N-m (332 Ib ft); check gaps; repeat until 0.13 mm (0.005 inch) or less; begin with Step 5.
- Install dial indicator on base with tip next to support mounting bolt (4); put tip on support (3); check while tightening bolt to final torque; if indicator moves more than 0.13 mm (0.005 inch), insta
Alignment Of Electric Sets Without Supports At The Flywheel Housing adjustment
Tools: shims, torque wrench
- Loosen all bolts connecting base to foundation; loosen all bolts fastening generator supports and engine supports to base.
- Ensure clearance between bolts and bolt holes in base, engine supports, generator supports at all locations.
- Check clearance between base and foundation at all mounting locations; use shims to prevent base deflection; tighten base-to-foundation bolts to final torque.
- Check clearance between base and engine, base and engine supports, base and generator supports over entire length; use shims to prevent support deflection; tighten all mounting bolts to final torque.
Belts - Adjusting the Alternator Belt adjustment
- Remove the drive belt guard.
- Loosen mounting bolt (1), adjusting nuts (2) and mounting bolt (3).
- Turn adjusting nuts (2) to increase or decrease drive belt tension.
- Tighten adjusting nuts (2), mounting bolt (3), and mounting bolt (1).
- Reinstall the drive belt guard.
- If new belts installed, recheck tension after 30 minutes at rated rpm.
Belts - Inspect/Adjust/Replace adjustment
⚠ Slippage of loose belts can reduce efficiency of driven components
⚠ Too tight belts place unnecessary stress on components
- Remove the drive belt guard.
- Loosen mounting bolt, adjusting nuts and mounting bolt.
- Turn adjusting nuts to increase or decrease drive belt tension.
- Tighten adjusting nuts and both mounting bolts to proper torque.
- Reinstall the drive belt guard.
- If new drive belts are installed, recheck tension after 30 minutes.
Rechecking The Alignment adjustment
Tools: torque wrench, shims
- Loosen the sixteen close coupled adapter bolts (2); visually ensure they are centered in clearance holes.
- Check gaps at 3, 6, 9, and 12 o'clock positions; use 2, 4, 8, and 10 o'clock if 12 and 6 are inaccessible.
- If gaps are between 0.03 mm (0.001 inch) and 0.13 mm (0.005 inch), tighten all bolts; alignment check complete. If not, loosen bolts fastening generator to base frame; adjust shims; move rear of gener
- After adjustment, tighten generator mounting bolts to one half of standard torque 450 N-m (332 lb ft); repeat procedure starting with Step 1.
Air Shutoff - Test (ADEM II Engine Control Modules) diagnostic
⚠ Check the wiring for the air shutoff switches, and for the solenoids
- Do not start the engine; ensure engine control is OFF.
- Verify both air shutoff gates latched OPEN and switches connected.
- Turn panel power ON; gates should remain open.
- Activate EMERGENCY STOP; both gates should close.
- Reset; latch only right gate; power ON; right gate should close.
- Latch only left gate; power ON; left gate should close.
- Operate engine normally; ensure gates remain latched.
Generator Winding Insulation - Test diagnostic
⚠ High voltage can cause electrocution. Discharge instrument leads and generator windings.
Tools: 300-8648 Insulation Testing Gp
- Take the generator out of service.
- Visually inspect generator for moisture. If moisture exists, dry the unit first.
- Inspect installation. Determine equipment that will be tested.
- Discharge capacitance of the windings. Disconnect 'T0' from ground.
- Disconnect sensing lead wires for regulator and PT leads of load share module.
- Connect insulation tester Black lead to ground; RED lead to 'T0'.
- Set voltage to rated voltage. Apply voltage; observe readings at 30 and 60 seconds.
- Record 60 second reading (correct for temperature), temperature, and humidity.
Installation Of The Generator For Generator Sets That Are Equipped With A 3500 Engine installation
⚠ Damage to engine and generator can result if electric set is operated with a plate assembly that does not have proper clearance.
⚠ If N or O is less than initial A, disassemble and check coupling plate for bowing; replace if bowed.
Tools: dial indicator, straight edge, magnetic bases, crane, torque wrench, 17 5N-4478 Plates
- Ensure generator is disengaged from engine; clean generator support and base contact surfaces; remove protective material from flywheel pilot bearing bore and coupling contact surface.
- Remove two engine side covers; rotate engine until no. 1 crankshaft throw is perpendicular; measure crankshaft end play with dial indicator; record as A and divide by two for B.
- With crankshaft at extreme forward position, measure distance from straight edge to flywheel housing mounting surface (C) and flywheel pilot surface (D); subtract D from C for E.
- Remove coupling bolts and washers; remove plates, shims, and exhaust fan; lift rotor; locate rotor so air gap equal; move rotor to extreme rear.
- Place dial indicator on vertical surface of heat sink at rear of rotor shaft; measure rotor end play (approximately 3.81 to 7.62 mm); record F and divide by two for G.
- Move rotor to extreme rear; position straight edge across mounting ring diameter; measure distance to mounting ring surface (H) and hub mounting surface (I); subtract H from I for J.
- Bolt a standard set of 17 5N-4478 Plates together; measure thickness in two locations along contour; average as K.
- Determine number of shims: subtract B, E, G, K from J for L; divide L by 0.8 mm (0.03 inch) for M; round up.
- Put coupling plate in flywheel bore; check clearance between coupling plate outside diameter and flywheel bore inside diameter.
- Install coupling plate assembly, bolts (6) and calculated shims; tighten bolts (5) in 180 degree intervals in three stages to 525 + 25 N-m (390 + 20 lb ft).
- Install guide bolts in flywheel; put generator on engine; install bolts (10); tighten to 100 N-m (75 lb ft) in pairs at 180 degree intervals in three stages.
- While crane supports generator, place dial indicator on heat sink vertical surface; push generator forward within + 0.50 mm (+ 0.0200 inch) of midpoint of end play.
- Install fan mounting bolts (11) into flywheel; tighten to 200 N-m (150 Ib ft) in pairs at 180 degree intervals in three stages.
- Place dial indicators on no. 1 crankshaft throw and heat sink; push crankshaft forward; check crankshaft end play 0.178 to 0.635 mm and heat sink end play 0.076 to 0.635 mm; record N and O.
- If N or O is less than initial A, disassemble; check coupling plate for bowing; replace if bowed; check calculations; install generator and repeat steps 13 and 15.
Installation Of The Generator For Generator Sets That Are Not Equipped With A 3500 Engine installation
⚠ Damage to engine and generator can result if electric set is operated with a plate assembly that does not have proper clearance.
Tools: dial indicator, indicator assembly, bar, torque wrench, guide bolt, crane
- Remove dirt, burrs, paint from generator support and base contact surfaces; remove protective material from flywheel pilot bearing bore and coupling contact surface.
- Remove timing pointer cover; install indicator assembly on front of engine; tip contacts crankshaft pulley face.
- Position plate assembly in flywheel bore; check clearance between plate outside diameter and bore inside diameter.
- Install full shim pack and plate assembly on generator with bolts; tighten bolts to 525 + 45 N-m (390 + 30 lb ft).
- Install guide bolt in flywheel; put generator on engine; install bolts (9) and (10); tighten but do not bend locks under bolts (8).
- Use dial indicator to check crankshaft end play; if reading differs from initial, remove generator and enough shims to get original end play.
- Install generator again and check crankshaft end play; after correct shims, bend locks under bolts (8).
Aftercooler Core - Inspect/Clean maintenance
⚠ Do not use a high concentration of caustic cleaner
⚠ Do not use high pressure when the fins are cleaned
- Remove the core.
- Turn the aftercooler core on one side; remove accessible debris.
- Back flush the core with cleaner.
- Remove the drain plug; steam clean the core; flush the fins.
- Wash the core with hot, soapy water.
- Flush thoroughly with clean, fresh water until clear.
- Dry the core with compressed air opposite to normal flow direction.
- Inspect O-rings/seals; pressure test for leaks; install the core.
Automatic Transfer Switch Semi-Annual Service maintenance
- Verify proper operation of exerciser clock; adjust if necessary.
- Provide visual inspection of all contacts and connection points.
- Perform building load test if practical and inspect for proper transfer and re-transfer.
- Verify operation of all control lamps.
Batteries - Replace maintenance
⚠ Batteries give off combustible gases which can explode; ensure proper ventilation.
⚠ Always recycle a battery; never discard a battery.
- Turn key start switch OFF. Remove key and all electrical loads.
- Turn OFF battery charger. Disconnect the charger.
- Disconnect NEGATIVE '-' cable from NEGATIVE battery terminal.
- Disconnect POSITIVE '+' cable from POSITIVE battery terminal.
- Remove the used battery. Install the new battery.
- Connect starting motor cable to POSITIVE '+' battery terminal.
- Connect ground plane cable to NEGATIVE '-' battery terminal.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the Caterpillar 3508?
The Caterpillar 3508 is rated 620 kW standby.
Which engine powers the Caterpillar 3508?
The Caterpillar 3508 is powered by the Caterpillar 3508B engine.
What fuel does the Caterpillar 3508 use?
The Caterpillar 3508 runs on diesel.
What's the oil capacity on a Caterpillar 3508?
The Caterpillar 3508B engine in the Caterpillar 3508 has an oil capacity of 397.0 liters.
How much coolant does the Caterpillar 3508 hold?
The Caterpillar 3508 cooling system holds 285 liters (75.3 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Caterpillar 3508?
The Caterpillar 3508 is rated 485 kW prime (641 kVA), against 620 kW standby.
What is the dry weight of the Caterpillar 3508?
The Caterpillar 3508 has a dry weight of 10136 kg (22346 lb).
What voltage does the Caterpillar 3508 produce?
The Caterpillar 3508 is offered in 600 V, 3 phase-phase.
What alternator does the Caterpillar 3508 use?
The Caterpillar 3508 uses a SR4 alternator.
What oil filter does the Caterpillar 3508 use?
The Caterpillar 3508 uses oil filter part number 1R0716.
Which fuel filter part number does the Caterpillar 3508 take?
The Caterpillar 3508 uses fuel filter part number 1R0755.
Which air filter part number does the Caterpillar 3508 take?
The Caterpillar 3508 uses air filter part number 106-3973.
Repair guides
9- Aftercooler Core - Inspect/Clean
- Air Shutoff - Test (ADEM II Engine Control Modules)
- Air Shutoff - Test (Engines with ADEM II ECM)
- Batteries - Replace
- Belts - Adjusting the Alternator Belt
- Engine Crankcase Breather - Clean
- Fuel System Primary Filter - Clean/Inspect/Replace
- Generator Winding Insulation - Test
- Turbocharger - Cleaning and Inspecting
Step-by-step procedures compiled from the Caterpillar service manual for this model.
Parts
68| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 106-3973 | Air filter inner | 1 | Air filter | Amazon eBay $79.98 eBay $39.31 NAPA $116.29 FridayParts $62.16 |
| 10R9951 | Head Gaskets | 1 | Gasket | Amazon eBay |
| 113-8432 | Front seal | Seal | Amazon eBay $128.48 | |
| 133-5673 | Fuel/Water Separator | 1 | Fuel filter | Amazon eBay $19.99 eBay $19.99 NAPA $70.35 KuduParts $19.00 FridayParts $20.99 |
| 141-7116 | V-belt | 1 | Belt | eBay $31.99 NAPA $16.79 FridayParts $22.60 |
| 1744947 | Aftercooler and Lines Gaskets | 1 | Gasket | Amazon eBay |
| 175-7546 | Oil Filter Cutter | 1 | Oil filter | Amazon eBay |
| 1R-0716 | Engine Oil | 1 | Oil filter | Amazon eBay $44.90 eBay $44.90 NAPA $33.79 NAPA $33.79 KuduParts $80.00 FridayParts $81.99 |
| 1R-0749 | Fuel Secondary - ADV | 1 | Fuel filter | Amazon Amazon eBay $135.88 eBay $135.88 NAPA $28.51 NAPA $28.51 KuduParts $17.00 FridayParts $47.50 |
| 1R-0755 | High Efficiency Fuel Filter | 1 | Filter | Amazon eBay $34.99 eBay $96.90 NAPA $82.67 NAPA $82.67 KuduParts $54.00 FridayParts $71.99 |
| 1R-1808 | Engine Oil - ADV | 1 | Oil filter | Amazon eBay $141.00 eBay $59.99 NAPA $45.70 NAPA $45.70 KuduParts $80.00 FridayParts $81.99 |
| 1R0716 | Filter oil | Oil filter | Amazon eBay $44.90 eBay $44.90 NAPA $33.79 NAPA $33.79 KuduParts $80.00 FridayParts $81.99 | |
| 1R0719 | Filter oil | Oil filter | eBay $20.00 FridayParts $31.32 KuduParts $58.00 | |
| 1R0726 | Filter oil | Oil filter | eBay $39.99 KuduParts $17.00 FridayParts $19.48 | |
| 1R0741 | Filter hydraulic | Hydraulic filter | eBay $22.00 NAPA $25.37 | |
| 1R0750 | Filter fuel | Fuel filter | Amazon eBay $33.80 eBay $33.80 NAPA $21.82 NAPA $21.82 KuduParts $17.00 FridayParts $29.50 | |
| 1R0755 | Filter fuel | Fuel filter | Amazon eBay $34.99 eBay $96.90 NAPA $82.67 NAPA $82.67 KuduParts $54.00 FridayParts $71.99 | |
| 1R0756 | Filter fuel | Fuel filter | Amazon eBay $18.99 eBay $18.99 NAPA $34.69 KuduParts $33.00 FridayParts $34.98 | |
| 1U-5490 | Hydrosolv 4165 liquid cleaner, 19 L (5 US gallon) | Fluid | Amazon eBay | |
| 1U-5492 | Hydrosolv 100 Liquid Cleaner, 19 L (5 US gal) | Fluid | eBay | |
| 1U-5718 | Vacuum Pump | 1 | Pump | Amazon eBay $87.99 |
| 1U-8804 | Hydrosolv 100 Liquid Cleaner, 4 L (1 US gal) | Fluid | eBay | |
| 1U-8812 | Hydrosolv 4165 Liquid Cleaner, 4 L (1 US gal) | Fluid | eBay | |
| 200-4139 | axial seal filter | (axial seal) | Filter | Amazon eBay $40.00 |
| 212-8176 | Water pump | Pump | eBay $629.99 | |
| 222-5152 | Water pump repair kit | Pump | eBay $239.99 | |
| 225-6404 | radial seal filter | (radial seal) | Filter | Amazon eBay |
| 2322507 | Manifold Gaskets | 1 | Gasket | Amazon eBay |
| 2322521 | Turbocharger Gaskets | 1 | Gasket | Amazon eBay |
| 2322522 | Reman Injectors | 1 | Injector | Amazon eBay |
| 2342795 | Injector Seals/Gaskets | 1 | Gasket | Amazon eBay |
| 248-5513 | Thermostat | Thermostat | Amazon eBay $39.95 eBay $43.00 FridayParts $30.31 SinoCMP $59.00 | |
| 2W9727 | Water pump impeller | Impeller | eBay | |
| 3412C | Engine | Engine | Amazon eBay $74.99 FridayParts $18.21 KuduParts $114.00 | |
| 3508B | Engine | x | Engine | Amazon eBay $95.99 FridayParts $18.50 KuduParts $259.00 |
| 3S3875 | Filter fuel | Fuel filter | eBay $49.99 | |
| 4W3864 | Water pump seal | Seal | eBay $9.27 | |
| 5N-5561 | Silicone Lubricant | Fluid | Amazon eBay | |
| 8N6309 | Air filter outer | Air filter | eBay $89.68 NAPA $186.85 KuduParts $185.00 FridayParts $290.20 | |
| 8T-5571 | Hydrosolv 100 - 208 L (55 US gallon) | Fluid | eBay | |
| 8T-7570 | Hydrosolv 4165 - 208 L (55 US gallon) | Fluid | eBay | |
| 9G8010 | Switch | Sensor | eBay $39.00 FridayParts $16.90 | |
| 9S-8140 | Pressurizing Pump | Pump | Amazon eBay | |
| AR86745 | FUEL FILTER | 1 | Fuel filter | Amazon eBay $42.15 KuduParts $16.00 |
| ESD5526 | Speed Controller | Speed controller | Amazon eBay | |
| M-4660684 | Gasket Set - Central & Lower - 3508 | Gasket set | Amazon eBay | |
| R134a | Air conditioner | 50 | Air filter | Amazon Amazon eBay $585.30 eBay FridayParts $25.50 |
| RE508202 | FUEL FILTER | 1 | Fuel filter | Amazon eBay $19.49 NAPA $50.99 FridayParts $31.02 KuduParts $60.00 |
| 138-8440 | Component cleaner | Service part / kit | Amazon eBay | |
| 1440725 | Connecting rod | Service part / kit | Amazon eBay $630.00 | |
| 169-8373 | Fluid Sampling Bottle | 1 | Service part / kit | Amazon eBay $29.99 |
| 174-6854 | Hydrosolv 100 liquid cleaner, 19 L (5 US gallon) | Service part / kit | Amazon eBay NAPA $10.64 | |
| 1743191 | Reman Cylinder Heads | 1 | Service part / kit | Amazon eBay |
| 1U-8760 | Chain Wrench | 1 | Service part / kit | Amazon eBay |
| 206-5756 | PrimeTime Prime Only Configuration Kit | Kit | Service part / kit | Amazon eBay |
| 245-5829 | Coolant Battery Tester Refractometer | 1 | Service part / kit | Amazon eBay $98.00 |
| 249-0437 | Oxidation Catalyst Assembly - Round | 1 | Service part / kit | Amazon eBay |
| 294-7420 | Test Kit (refill ampoules for 298-5311 Coolant Nitrite Test Kit) | Service part / kit | Amazon eBay | |
| 298-5311 | Coolant Nitrite Test Kit for SCA | Service part / kit | Amazon eBay | |
| 3034NA | Oil Change Interval | Service part / kit | Amazon | |
| 4C-9301 | Coolant Conditioner Test Kit | 1 | Service part / kit | Amazon eBay $30.00 |
| 5P-3413 | Pipe Sealant | 1 | Service part / kit | eBay $12.37 |
| 8T-5296 | Coolant Conditioner Test Kit | Service part / kit | Amazon eBay eBay | |
| 9S-3263 | Thread lock | 1 | Service part / kit | eBay $30.78 |
| 9S-4030 | Thread lock | Service part / kit | eBay | |
| LEDW3153 | Supersedes LECW7527 | Service part / kit | Amazon eBay | |
| PEHJ0271 | Cat® Emissions Upgrade Kits for Select 3500 Marine Engines | Service part / kit | Amazon eBay | |
| PEHJ0287 | Cat® Performance Upgrade Kits for Select 3508, 3512, and 3516 Marine Engines | Service part / kit | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| 3.8 | 1.0 | ||
| 100% | 191.8 | 50.6 | |
| Continuous | 5.0 | 1.3 | |
| Prime | 10% | 39.0 | 10.3 |
| Prime | 20% | 62.0 | 16.38 |
| Prime | 25% | 74.0 | 19.55 |
| Prime | 30% | 87.0 | 22.98 |
| Prime | 40% | 112.0 | 29.59 |
| Prime | 50% | 137.0 | 36.19 |
| Prime | 60% | 160.0 | 42.27 |
| Prime | 70% | 183.0 | 48.34 |
| Prime | 75% | 194.0 | 51.25 |
| Prime | 80% | 206.0 | 54.42 |
| Prime | 90% | 232.0 | 61.29 |
| Prime | 100% | 259.0 | 68.42 |
Available documents