Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 2000 kW |
| Standby kVA | 2000 |
| Prime power | 1818 kW |
| Emissions | Tier I |
| Controller | Electronic Governor |
| Oil capacity | 11.5 L |
| Alternator | 512 M60 |
| Voltage options | 480/277 V, 440/254 V, 220/127 V, 208/120 V |
| Phase | Three phase |
| Rated current | 153 A |
| Power factor | Not specified |
| Circuit breaker | 153 A |
| Battery group | Not specified |
| Battery voltage | Not specified V |
| Battery quantity | Not specified |
| Max ambient | Not specified °C |
| Tank runtime | Not specified hr |
Filters for the MTU 16V4000G81
1Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Fuel / water separator | P552006 | Fuel Filter, Water Separator Spin-On Twist&Drain | MTU 4202934, NAPA 3645, BALDWIN BF1262, SISU 1273400331 | FridayParts $42.88 |
Common questions
How many kW is the SDMO EXEL 2 X 2000 UC?
The SDMO EXEL 2 X 2000 UC is rated 2000 kW standby (2000.0 kVA).
What engine is in the SDMO EXEL 2 X 2000 UC?
The SDMO EXEL 2 X 2000 UC is powered by the MTU 16V4000G81 engine.
What kind of fuel does the SDMO EXEL 2 X 2000 UC run on?
The SDMO EXEL 2 X 2000 UC runs on Diesel.
What's the oil capacity on a SDMO EXEL 2 X 2000 UC?
The MTU 16V4000G81 engine in the SDMO EXEL 2 X 2000 UC has an oil capacity of 11.5 liters.
What is the continuous rating of the SDMO EXEL 2 X 2000 UC?
The SDMO EXEL 2 X 2000 UC is rated 1818 kW prime (1818 kVA), against 2000 kW standby.
What voltages is the SDMO EXEL 2 X 2000 UC available in?
The SDMO EXEL 2 X 2000 UC is offered in 480/277 V, 440/254 V, 220/127 V, 208/120 V, Three phase-phase.
What size battery does the SDMO EXEL 2 X 2000 UC need?
The SDMO EXEL 2 X 2000 UC uses Not specified batteryies, Not specified V each, group Not specified, per the manufacturer specification sheet.
What alternator does the SDMO EXEL 2 X 2000 UC use?
The SDMO EXEL 2 X 2000 UC uses a 512 M60 alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Standby | 75% | 34.5 | 12.2 |
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.