Service parts for the KG150
Grouped by system, with how many of each the parts manual calls for.
Air intake
1 requiredFuel system
1 requiredOil system
1 requiredBelts
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | Gas |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 116 kW |
| Standby kVA | 145 |
| Prime power | 105 kW |
| Controller | APM603 |
| Oil capacity | 10.3 L |
| Alternator | 4RX, 4SX, 4TX |
| Voltage options | 120/208 V, 127/220 V, 120/240 V, 220/380 V, 254/440 V, 277/480 V, 115/200 V, 230/400 V, 240/416 V, 347/600 V |
| Phase | 3 |
| Rated current | 470 A |
| Power factor | 0.8 |
| Circuit breaker | 434 A |
| Battery group | one |
| Battery cranking | 925 CCA |
| Battery voltage | 12 V |
| Battery quantity | one |
Engine
| Oil capacity | 10.3 L |
|---|---|
| Coolant capacity | 10.3 L |
| Displacement | 10.3 L |
| Aspiration | Turbocharged |
| Rated speed | 1800 rpm |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Standard Duty | 4508301 | Amazon eBay $11.96 | ||
| Fuel filter | — | 1500 hr | |||
| Fuel filter | 2 Microns@ 98% Efficiency | GM50006 | Amazon $23.99 eBay $26.99 | ||
| Oil filter | 30 Microns | GM32809 | Amazon $57.96 eBay $26.25 | ||
| Battery | 2/12V, Wet | — | 1800 hr | ||
| Belt | Flexible disc | GM64496 | Amazon eBay $36.00 | ||
| Coolant | — | 15000 hr | |||
| Coolant filter | N/A | — | |||
| Oil | — | 3000 hr | |||
| Spark plug | N/A | — | 3600 hr |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Service intervals
27| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Wire-cable insulation breakdown | Test | 500 hr | 36 mo | Three Years or 500 Hrs; Visually Inspect and Test |
| APM603 RTC battery | Replace | 24 mo | Two Years, when indicated by the controller (range 2-10 years) | |
| Air ducts, louvers | Clean | 12 mo | Yearly; Check and Clean | |
| Battery charger operation, charge rate | Inspect | 1 mo | Monthly | |
| Battery electrolyte level | Check | 1 mo | Monthly | |
| Battery load testing | Test | 12 mo | Yearly | |
| Battery specific gravity, charge state | Test | 1 mo | Monthly | |
| Circuit breakers, fuses | Inspect | 1 mo | Monthly; Visually Inspect, Check, Replace as necessary, Clean, Test; do not break manufacturer's seals or internally inspect | |
| Coolant temperature protection level | Test | 6 mo | Six Months; follow engine manufacturer's manual | |
| Crankcase breather | Clean | 3 mo | Quarterly; follow engine manufacturer's manual | |
| Excessive back pressure | Test | 12 mo | Yearly | |
| Fan and alternator belts | Inspect | 1 mo | Monthly; follow engine manufacturer's manual, Replace as necessary | |
| Flexible connector(s) | Inspect | 6 mo | Six Months; Visually Inspect | |
| Fuel piping | Inspect | 12 mo | Yearly; Visually Inspect | |
| Hangers and supports | Inspect | 12 mo | Yearly; Visually Inspect | |
| Insulation, fire hazards | Inspect | 3 mo | Quarterly; Visually Inspect | |
| Louver motors and controls | Test | 12 mo | Yearly; Visually Inspect, Clean, Test | |
| Radiator exterior | Clean | 12 mo | Yearly; Check and Clean | |
| Recharge after engine start | Check | 1 mo | Monthly | |
| Remote control | Test | 1 mo | Monthly | |
| Remove corrosion, clean and dry battery and rack | Inspect | 1 mo | Monthly; Visually Inspect and Clean | |
| Run generator set | Test | 1 mo | Monthly | |
| Safety and alarm operation | Test | 6 mo | Six Months; Check and Test | |
| Tighten DC electrical connections | Check | 6 mo | Six Months | |
| Tighten control and power wiring connections | Check | 12 mo | Yearly | |
| Water supply to the heat exchanger | Check | 12 mo | Yearly | |
| Wire abrasions where subject to motion | Inspect | 3 mo | Quarterly; Visually Inspect and Check |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
7| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Other | Alternator end bracket bearing replacement interval | 10000 | hours | more frequently if annual inspection shows excessive rotor end play or bearing damage |
| Other | Battery specific gravity - charge threshold | 1.215 | at 26.7°C (80°F), charge battery if below this | |
| Other | Battery specific gravity - fully charged | 1.260 | at 26.7°C (80°F) | |
| Other | Battery specific gravity max cell-to-cell variance | 0.01 | ||
| Other | Gaseous fuel system leak test pressure | 6-8 | oz per sq in (10-14 in water column) | |
| Temperature | Battery specific gravity reference temperature | 26.7 | °C (80°F) | |
| Temperature | Battery specific gravity temperature correction factor | 0.004 | specific gravity points per 5.5°C (10°F) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
6Battery Specific Gravity Check diagnostic
Tools: Battery hydrometer
- Use a battery hydrometer to check specific gravity of electrolyte in each cell (filler-cap batteries only).
- Hold the hydrometer vertically and read the value.
- Correct the reading using the temperature correction table if the hydrometer lacks one.
- Battery is fully charged if corrected specific gravity is 1.260 at 26.7°C (80°F).
- Charge the battery if specific gravity is below 1.215 at 26.7°C (80°F).
- Maintain specific gravity within ±0.01 between cells.
Air Filter Element Replacement maintenance
⚠ Do not operate the generator set with the air cleaner removed.
- Remove the generator set from service (remove load, shut down, controller Out-of-Service mode, press emergency stop).
- Disconnect power to battery charger.
- Remove battery cables, negative lead first.
- Loosen the filter clamp and remove the filter element from the air intake elbow.
- Install new/cleaned filter element and tighten the filter clamp.
Battery Electrolyte Level Inspection maintenance
⚠ Battery acid can cause blindness and burn skin; wear splashproof goggles, rubber gloves, boots.
- Check the electrolyte level at the specified interval on batteries with filler caps.
- Remove the filler caps and verify electrolyte reaches the bottom of each filler hole.
- Refill as necessary with distilled water only (do not add fresh electrolyte).
- Tighten the filler caps.
- If water was added during freezing temperatures, run the generator set 20-30 minutes to mix electrolyte and water.
Procedure to Drain Cooling System maintenance
⚠ Hot coolant and steam can cause severe injury or death.
- Stop the generator set and allow it to cool.
- Deenergize the block heater, if equipped.
- Cover the pressure cap with a rag and remove it to prevent air pockets.
- Open the radiator and/or engine block coolant drain valve(s) and allow the system to drain.
- If mineral deposits or dirt/grease are present, proceed to flush and clean; otherwise proceed to refill.
Procedure to Refill Cooling System maintenance
⚠ Do not add coolant to a hot engine; wait until the engine has cooled.
- Cover the pressure cap with a rag and remove it.
- Close drain valve(s) and tighten hose clamps.
- Fill the cooling system with the recommended Kohler coolant mixture, from the bottom if possible.
- Replace the pressure cap.
- Operate the generator set until the thermostat opens (upper hose warms).
- Stop the engine, allow it to cool, check and repair any leaks.
- Remove pressure cap and add coolant to just below the overflow tube opening.
- Replace the pressure cap.
- Check coolant level in the sight glass; maintain between high and low marks.
- Reenergize the block heater, if equipped.
Radiator Maintenance maintenance
⚠ Avoid damaging fins with rough brushing or excessive jet pressure.
- Periodically check for leakage from core or tank connections.
- Inspect liquid level via the top tank sight glass at regular intervals.
- Test antifreeze before cold weather periods.
- For long standby periods, check top tank interior for scale/rust every 1-3 months.
- Remove dirt/debris from core face with compressed air, steam, or water (stand back at least 0.9 m/3 ft if using water, keep stream parallel to fins).
- Clean fan blades once per year using a stiff brush or air nozzle, or nonflammable solvent with brush for solid deposits.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What is the power rating of the Kohler KG150?
The Kohler KG150 is rated 116 kW standby (145.0 kVA).
What engine does the Kohler KG150 use?
The Kohler KG150 is powered by the Kohler KG10V08T-6CGS (NG)/KG10V08T-6DGS (LPG) engine.
Is the Kohler KG150 diesel or gas?
The Kohler KG150 runs on Gas.
What's the oil capacity on a Kohler KG150?
The Kohler KG10V08T-6CGS (NG)/KG10V08T-6DGS (LPG) engine in the Kohler KG150 has an oil capacity of 10.3 liters.
What alternator comes on the Kohler KG150?
The Kohler KG150 uses a 4RX, 4SX, 4TX alternator.
What oil filter does the Kohler KG150 use?
The Kohler KG150 uses oil filter part number GM32809.
Which fuel filter part number does the Kohler KG150 take?
The Kohler KG150 uses fuel filter part number GM50006.
What air filter fits the Kohler KG150?
The Kohler KG150 uses air filter part number 4508301.
Parts
5model family| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 343302 | Gas Filter Element | 1 | Service part / kit | Amazon eBay |
| ADV-9052D-D | Service part / kit | Amazon eBay | ||
| ADV-9116D-E | Service part / kit | Amazon eBay | ||
| GM75552 | Block Heater Kit | 1 | Service part / kit | Amazon |
| GM75553 | Block Heater Kit | 1 | Service part / kit | Amazon |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.