Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 275 kW |
| Standby kVA | 344 |
| Prime power | 248 kW |
| Emissions | EPA Certified Stationary Emergency |
| Controller | Digital H Control Panel- Dual 4x20 Display |
| Oil capacity | 30.0 L |
| Alternator | K0275124Y21 SD275 (4-pole, Class H insulation) |
| Voltage options | 120/208 V, 120/240 V, 277/480 V, 346/600 V |
| Phase | Three-Phase |
| Rated current | 954 A |
| Power factor | 0.8 |
| Circuit breaker | 954 A |
| Battery group | See Battery Index 0161970SBY |
| Battery cranking | 1155 CCA |
| Battery voltage | 24 VDC V |
| Battery quantity | 2 |
| Coolant capacity | 49.2 L |
| Max ambient | 43.3 °C |
| Dimensions (L×W×H) | 3493×1463×1722 mm |
| Dry weight | 3382 kg |
| Sound level | 89.1 dBA @ 1 m |
| Fuel tank | 946.0 L |
| Tank runtime | 48 hr |
Engine
| Oil capacity | 30.0 L |
|---|---|
| Coolant capacity | 49.2 L |
| Displacement | 10.3 L |
| Aspiration | Turbocharged/Aftercooled |
| Rated speed | 1800 rpm |
Maintenance & consumables
for the Iveco/FPT 10.3L| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Fuel filter | 5 | — | 9 hr | ||
| Oil filter | Full Flow | — | 9 hr | ||
| Battery | 2 | ×2 | — | 9 hr | |
| Belt | Fan Guard | — | 9 hr | ||
| Coolant | 50/50 Ethylene Glycol Antifreeze | 63.0 L | — | 9 hr | |
| Oil | 30 | 31.68 L | — | 9 hr | |
| Spark plug | 4-Valve | — | 9 hr |
Common questions
How many kW is the Generac SD275?
The Generac SD275 is rated 275 kW standby (344.0 kVA).
What engine does the Generac SD275 use?
The Generac SD275 is powered by the Iveco/FPT 10.3L engine.
What kind of fuel does the Generac SD275 run on?
The Generac SD275 runs on Diesel.
What is the oil capacity of the Generac SD275?
The Iveco/FPT 10.3L engine in the Generac SD275 has an oil capacity of 30.0 liters.
How much coolant does the Generac SD275 hold?
The Generac SD275 cooling system holds 49.2 liters (13.0 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the Generac SD275?
The Generac SD275 is rated 248 kW prime (309 kVA), against 275 kW standby.
How loud is the Generac SD275?
The Generac SD275 is rated at 89.1 dBA at 1 m, per the manufacturer specification sheet.
What is the dry weight of the Generac SD275?
The Generac SD275 has a dry weight of 3382 kg (7456 lb).
What size fuel tank does the Generac SD275 have?
The Generac SD275 has a 946 liter (250 US gallon) fuel tank, giving about 48 hours of runtime.
What voltages is the Generac SD275 available in?
The Generac SD275 is offered in 120/208 V, 120/240 V, 277/480 V, 346/600 V, Three-Phase-phase.
How many cold cranking amps does the Generac SD275 require?
The Generac SD275 uses 2 batteryies, 24 VDC V each, 1155 CCA, group See Battery Index 0161970SBY, per the manufacturer specification sheet.
What alternator does the Generac SD275 use?
The Generac SD275 uses a K0275124Y21 SD275 alternator. It has 4 poles. Insulation class H.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 25% | 23.5 | 6.2 |
| Prime | 25% | 24.6 | 6.5 |
| Prime | 50% | 39.7 | 10.5 |
| Prime | 75% | 55.2 | 14.6 |
| Prime | 80% | 48.1 | 12.7 |
| Prime | 100% | 25.6 | 6.76 |
| Standby | 25% | 25.7 | 6.8 |
| Standby | 50% | 44.2 | 11.7 |
| Standby | 70% | 25.7 | 6.8 |
| Standby | 75% | 59.81 | 15.8 |
| Standby | 100% | 74.2 | 19.6 |