Generac MLT4200IV Generator Set

The Generac MLT4200IV is a 30 kW (40.2 kVA) standby generator set powered by a Isuzu 4LE2TAGV-08 engine. It is available at 120 V and 240 V, single-phase, 60 Hz and rated 167 A. It holds about 8 L (2.1 gal) of oil. Starting uses 1 group-24 battery rated 720 CCA at 12 V. The set measures 2920×2590×2130 mm (115.0×102.0×83.9 in), weighs about 991 kg (2185 lb) and produces 70 dBA at 23 m.

30 kW
Standby
2.18 L
Displacement
8.0 L
Oil capacity
1
Document types

How to read your Generac serial & model number →

Service parts for the MLT4200IV

Grouped by system, with how many of each the parts manual calls for.

Fuel system

1 required
69858Fuel filter$15.34NAPA

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Frequency60.0 Hz
Standby power30 kW
Standby kVA40
Prime power27 kW
ControllerPowerZone–DLA
Oil capacity8.0 L
AlternatorMarathon 334CSA3028
Voltage options120 V, 240 V
Phasesingle phase
Rated current167 A
Power factor1
Circuit breaker100 A
Battery group24
Battery cranking720 CCA
Battery voltage12.0 V
Battery quantity1
Dimensions (L×W×H)2920×2590×2130 mm
Dry weight991 kg
Sound level70.0 dBA @ 23.0 m
Tank runtime24.5 hr

Engine

Isuzu 4LE2TAGV-08
Displacement2.18 L
Rated speed1800 rpm

Maintenance & consumables

for the Isuzu 4LE2TAGV-08
ItemSpecCapacityPart #Interval
Air filterInspect and replace air filter element as required.—
Fuel filter69858 Amazon eBay $21.83 NAPA $15.34 FridayParts $36.28
Oil filter670570304500 hr Amazon eBay $16.89 PartsGeek $7.98 NAPA $9.09 FridayParts $20.19
BatteryInspect battery condition; replace if necessary.—1000 hr
BeltInspect and replace fan belt as required.—
CoolantCheck coolant level daily; add coolant if needed.—1000 hr
OilChange oil and oil filter every 500 hours after initial break-in.4.7 L—500 hr
Spark plug—

Compatible filters for the Isuzu 4LE2TAGV-08 — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.

  • Air filter: Generac OE3557 Generac OE3656 Isuzu 8972319000 Isuzu 5864014350 Isuzu 8972599390

Common questions

How many kW is the Generac MLT4200IV?

The Generac MLT4200IV is rated 30 kW standby (40.2 kVA).

What engine does the Generac MLT4200IV use?

The Generac MLT4200IV is powered by the Isuzu 4LE2TAGV-08 engine.

How much oil does the Generac MLT4200IV take?

The Generac MLT4200IV has an engine oil capacity of 8 liters (8.5 US quarts), per the manufacturer specification sheet.

What is the continuous rating of the Generac MLT4200IV?

The Generac MLT4200IV is rated 27 kW prime (36 kVA), against 30 kW standby.

What is the sound level of the Generac MLT4200IV?

The Generac MLT4200IV is rated at 70.0 dBA at 23.0 m, per the manufacturer specification sheet.

How much does the Generac MLT4200IV weigh?

The Generac MLT4200IV has a dry weight of 991 kg (2184 lb).

What voltage does the Generac MLT4200IV produce?

The Generac MLT4200IV is offered in 120 V, 240 V, single phase-phase.

What size battery does the Generac MLT4200IV need?

The Generac MLT4200IV uses 1 battery, 12.0 V each, 720 CCA, group 24, per the manufacturer specification sheet.

What alternator comes on the Generac MLT4200IV?

The Generac MLT4200IV uses a Marathon 334CSA3028 alternator.

What oil filter fits the Generac MLT4200IV?

The Generac MLT4200IV uses oil filter part number 670570304.

Which fuel filter part number does the Generac MLT4200IV take?

The Generac MLT4200IV uses fuel filter part number 69858.

What air filter does the Generac MLT4200IV use?

The Generac MLT4200IV uses air filter part numbers GENERAC OE3557, GENERAC OE3656.

Troubleshooting

38

Symptoms & remedies

SymptomCauseRemedy
Unit cranks but does not startLow fuel levelVerify fuel level in tank.
Unit cranks but does not startRestricted air filterInspect air filter for blockage.
Unit cranks but does not startFuel flow obstructedInspect fuel supply hose from tank to fuel filter for cracks and abrasion; Inspect for gelled fuel in fuel system in cold weather, especially at fuel filter; Check fuel pump operation.
Unit cranks but does not startAir in fuel systemPurge air from fuel system.
Unit cranks but does not startGlow plug(s) inoperableSee the OEM engine manual for more information.
Unit starts but stumbles and diesLow ambient temperatureVerify if ambient temperature is within unit limits.
Unit starts but stumbles and diesIntake heat inoperableInspect engine air inlet heater function.
Unit starts but stumbles and diesAir in fuel linesPurge air from fuel lines.
High coolant temperature shutdownLow coolant levelAllow engine to cool. Check coolant level in radiator. Add coolant level if needed.
High coolant temperature shutdownBlockage in radiatorInspect radiator shroud and ducting for blockage and remove any foreign matter.
High coolant temperature shutdownDebris on radiator faceInspect for visible leaks. Check tension of water pump drive belt.
High coolant temperature shutdownBroken coolant pump beltContact a GMASD to replace.
High coolant temperature shutdownCooling fan inoperableRemove load on generator and restart engine; Check coolant temperature and shut engine down immediately if it starts to overheat.
Low oil pressure shutdownLow oil levelCheck oil level.
Low oil pressure shutdownOil pump inoperableContact a GMASD
Unit stalls when export power is usedLoad exceeds unit ratingTurn outlet breaker ON and load sense switch OFF, confirm generator output is 60 Hz ± 2 Hz. Reapply load.
Mast lights off, checking inside control boxLoose lighting connectionsInspect the connections inside the control box.
Mast lights off, checking inside control boxLoose mast cable connectorVerify outside connector is connected properly to inside control box.
Mast lights off, checking inside control boxGenerator output incorrectCheck the incoming voltage to the ballast driver by checking the available voltage on the GFCI receptacle. Incoming voltage should be 120V ± 5V. If voltage is incorrect, the generator may require service.
One or more lights do not turn onLight breaker tripped.Inspect light breakers.
One or more lights do not turn onLights not turned onInspect electronic control to see if lights are on. Turn lights on.
Unit is inoperative — Read/Write configuration does not operateCheck the battery and wiring to the unit; Check the DC supply; Check the DC fuse.
Unit shuts downCheck DC supply voltage is not above 35 V or below 9 V; Check the operating temperature is not above 70 °C. Check the DC fuse.
Fail to Start is activated after pre-set number of attempts to startCheck wiring of fuel solenoid. Check fuel. Check battery supply. Check battery supply is present on the Fuel output of the module. Check the speed-sensing signal is present on the controller inputs. See engine manual.
Continuous starting of generator when in AUTO modeCheck that there is no signal present on the Remote Start input. Check configured polarity is correct; Check the mains supply is available and within configured limits
Generator fails to start on receipt of Remote Start signal.Check Start Delay timer has timed out; Check signal is on Remote Start input. Confirm correct configuration of input is configured to be used as Remote Start; Check that the oil pressure switch or sensor is indicating low oil pressure to the controller. Depending on configuration, then set does not start if oil pressure is not low.
Pre-heat inoperativeCheck wiring to engine heater plugs. Check battery supply. Check battery supply is present on the Pre-heat output of module. Check pre-heat configuration is correct.
Starter motor inoperativeCheck wiring to starter solenoid. Check battery supply. Check battery supply is present on the Starter output of module. Ensure oil pressure switch or sensor is indicating the low oil pressure state to the controller.
Engine runs but the lights do not turn onCheck Warm up timer has timed out; Ensure Inhibit Light Input 1, 2, 3 or 4 are not active on the module inputs; Check connections to the lights; The genset may not take load in MANUAL/START Mode unless there is an active load signal.
Incorrect reading on engine gauges — Fail To Stop when engine is at restCheck engine is operating correctly; Check that sensor is compatible with the controller and that the controller configuration is suited to the sensor.
Low Oil Pressure operates after engine has firedCheck engine oil pressure; Check oil pressure switch/sensor and wiring; Check configured polarity (if applicable) is correct (i.e. Normally Open or Normally Closed) or that sensor is compatible with the controller and is correctly configured.
High Coolant Temperature operates after engine has fired.Check engine temperature; Check switch/sensor and wiring; Check configured polarity (if applicable) is correct (i.e. Normally Open or Normally Closed) or that sensor is compatible with the controller.
Shutdown fault operatesCheck relevant switch and wiring of fault indicated on LCD display; Check configuration of input.
Electrical Trip fault operatesCheck relevant switch and wiring of fault indicated on LCD display; Check configuration of input.
Warning fault operatesCheck relevant switch and wiring of fault indicated on LCD display; Check configuration of input.
CAN ECU Warning / CAN ECU ShutdownThis indicates a fault condition detected by the engine ECU and transmitted to the controller.
CAN Data FailIndicates failure of the CAN data link to the engine ECU.Check all wiring and termination resistors (if required).
Controller seems to revert to an earlier configurationWhen editing a configuration using the PC software it is vital that the configuration is first read from the controller before editing it. This edited configuration must then be written back to the controller for the changes to take effect; When editing a configuration using the fascia editor, be sure to press the AUTO Mode button to save the change before moving to another item or exiting the fascia editor

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Fuel consumption

RatingLoadL/hgal/h
Prime7.952.1
Standby29.537.8

Available documents

Owner's manual — A0003354601 (Generac)

This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Fuel filter 69858$15.34
Oil filter 670570304$7.98
2 priced items$23.32