HomeEnginesIsuzu 4LE2TAGV-08

Isuzu 4LE2TAGV-08 Engine

The Isuzu 4LE2TAGV-08 is a 2.18 L engine rated at 1800 rpm, producing up to 36.2 kW. It powers generator sets from Generac, including the MLT4200IV.

Also known as: Isuzu 4LE2TAGV-08

Part of the Isuzu 4LE2TAGV engine family — 2 variants share parts & fitment.

2.18 L
Displacement
1800 rpm
Rated speed
36 kW
Gross power

Service parts for the 4LE2TAGV-08

The cheapest captured merchant offer per filter — see the full cross-reference below for every OEM/aftermarket option.

Air intake

1 required
OE3557Air filterfind

Fuel system

1 required

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Verify against your serial number before ordering.

Engine specifications

Displacement2.18 L
Rated speed1800 rpm
Gross power36 kW

Generator sets powered by this engine

1

Common problems

7
  • Unit starts but stumbles and dies
    Cause: Low ambient temperature, Intake heat inoperable, Air in fuel lines, High coolant temperature shutdown
    Fix: Verify if ambient temperature is within unit limits., Inspect engine air inlet heater function., Purge air from fuel lines., Allow engine to cool. Check coolant level in radiator. Add coolant level if needed., Inspect radiator shroud and ducting for blockage and remove any foreign matter., Inspect for visible leaks. Check tension of water pump drive belt., Contact a GMASD to replace., Remove load on generator and restart engine. Check coolant temperature and shut engine down immediately if it starts to overheat.
  • Unit cranks but does not start
    Cause: Low fuel level, Restricted air filter, Fuel flow obstructed, Air in fuel system, Glow plug(s) inoperable
    Fix: Verify fuel level in tank., Inspect air filter for blockage., Inspect fuel supply hose from tank to fuel filter for cracks and abrasion., Check fuel pump operation., Purge air from fuel system., See the OEM engine manual for more information.
  • One or more lights do not turn on
    Cause: Light breaker tripped.
    Fix: Inspect light breakers.
  • Mast lights off, checking inside control box
    Cause: Loose lighting connections
    Fix: Inspect the connections inside the control box.
  • Loose mast cable connector
    Fix: Verify outside connector is connected properly to inside control box.
  • Lights not turned on
    Cause: Inspect electronic control to see if lights are on. Turn lights on.
    Fix: Turn lights on. If problems continue, contact Generac Mobile at 1-800-926-9768 for assistance.
  • Generator output incorrect
    Fix: Check the incoming voltage to the ballast driver by checking the available voltage on the GFCI receptacle. Incoming voltage should be 120V ± 5V. If voltage is incorrect, the generator may require service.

Compiled from service & troubleshooting documentation across every generator set that uses the Isuzu 4LE2TAGV-08.

Maintenance schedule

ItemSpecCapacityPart #Interval
Air filterInspect and replace air filter element as required.
Fuel filterReplace fuel filter element as required.69858 Amazon $21.83 eBay $21.83 FridayParts $36.28
Oil filter670570304500 hr Amazon eBay $16.89 PartsGeek $7.98 FridayParts $20.19
Battery1000 hr
BeltInspect and replace fan belt as required.
Coolant1000 hr
Oil4.7 L500 hr
Spark plug

Pooled from every document that names this exact engine — confirm the interval and part number against your unit's serial number.

Parts cataloged across the Isuzu 4LE2TAGV family

4
Part #DescriptionCategory
90243Air Filter Elementair_filter
01035Central Lift Pointcentral_lift_point
01144Controllercontroller
209649Form: SFC626Bother_service

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Filters for this engine

  • Air filter: Generac OE3557 Generac OE3656 Isuzu 8972319000 Isuzu 5864014350 Isuzu 8972599390 Donaldson P827653 Donaldson P821575 Donaldson P822858
  • Fuel filter: Generac 69858 Isuzu 8944015310 Isuzu H132401 Donaldson P502166 Donaldson P550057 Wix 33263 Wix 33386 Ac Delco TP1231
  • Oil filter: Generac 670570304 Isuzu 5876100080 Donaldson P550162 Wix 51334 Ac Delco X45

Cross-referenced via Donaldson + OEM/engine-maker interchange — options to verify against your serial number, not confirmed for every exact variant.

Also used in

3
  • Hitachi ZX40U — Excavator Compact
  • Hitachi ZX50U — Excavator Compact
  • Kobelco SK80 — Excavator Tracked

Other equipment known to use this engine, via filter-application cross-reference — useful for sourcing parts even when your exact machine isn't listed elsewhere on this page.

Common questions

What is the displacement of the Isuzu 4LE2TAGV-08?

The Isuzu 4LE2TAGV-08 has a displacement of 2.18 liters.

Which generators use the Isuzu 4LE2TAGV-08 engine?

The Isuzu 4LE2TAGV-08 powers 1 generator set(s), including Generac MLT4200IV.

What oil filter does the Isuzu 4LE2TAGV-08 use?

The Isuzu 4LE2TAGV-08 uses oil filter part numbers Generac 670570304, Isuzu 5876100080, Donaldson P550162.

What fuel filter does the Isuzu 4LE2TAGV-08 use?

The Isuzu 4LE2TAGV-08 uses fuel filter part numbers Generac 69858, Isuzu 8944015310, Isuzu H132401.

What air filter does the Isuzu 4LE2TAGV-08 use?

The Isuzu 4LE2TAGV-08 uses air filter part numbers Generac OE3557, Generac OE3656, Isuzu 8972319000.

How often should you change the oil in the Isuzu 4LE2TAGV-08?

The Isuzu 4LE2TAGV-08 oil change interval is every 500 hours.

What is a common problem with the Isuzu 4LE2TAGV-08 engine?

A commonly reported issue on generators using the Isuzu 4LE2TAGV-08 is: Unit starts but stumbles and dies. Cause: Low ambient temperature, Intake heat inoperable, Air in fuel lines, High coolant temperature shutdown. Fix: Verify if ambient temperature is within unit limits., Inspect engine air inlet heater function., Purge air from fuel lines., Allow engine to cool. Check coolant level in radiator. Add coolant level if needed., Inspect radiator shroud and ducting for blockage and remove any foreign matter., Inspect for visible leaks. Check tension of water pump drive belt., Contact a GMASD to replace., Remove load on generator and restart engine. Check coolant temperature and shut engine down immediately if it starts to overheat..