Home›Generac›Generac MLT4200IF4

Generac MLT4200IF4 Generator Set

The Generac MLT4200IF4 is a 20 kW (36.2 kVA) diesel standby generator set powered by a Isuzu 4LE2TAGV-03 engine. It is available at 120/240 V, single-phase, 60 Hz and rated 167 A. It holds about 10.4 L (2.7 gal) of oil and 17 L (4.5 gal) of coolant, with a maximum ambient rating of 49 °C. Starting uses 1 battery rated 720 CCA at 12 V. The set measures 2921×1727×2718 mm (115.0×68.0×107.0 in), weighs about 1033 kg (2277 lb) and produces 68 dBA at 7 m. An integrated tank holds 194.5 L (51.4 gal), roughly 48 hours of runtime. The same 4LE2TAGV-03 engine also powers generator sets from Isuzu, John Deere and Magnum.

20 kW
Standby
2.18 L
Displacement
10.4 L
Oil capacity
2
Document types

How to read your Generac serial & model number →

Typical fuel consumption for 20–25 kW Diesel generators →

Compare with other 20–25 kW Diesel generators →

Service parts for the MLT4200IF4

Grouped by system, with how many of each the parts manual calls for.

Fuel system

1 required
69858Fuel filter$15.34NAPA

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Fueldiesel
Frequency60.0 Hz
Standby power20 kW
Prime power20 kW
Emissions4
ControllerEngraved aluminum punched
Oil capacity10.4 L
AlternatorMarathon 334CSA3028
Voltage options120/240 V
PhaseSingle
Rated current167 A
Circuit breaker100 A
Battery cranking720 CCA
Battery voltage12 V
Battery quantity1
Max ambient49 °C
Dimensions (L×W×H)2921×1727×2718 mm
Dry weight1033 kg
Wet weight1176 kg
Sound level68.0 dBA @ 7 m
Fuel tank194.5 L
Tank runtime48 hr

Engine

Isuzu 4LE2TAGV-03
Oil capacity10.4 L
Coolant capacity17.0 L
Displacement2.18 L
AspirationLiquid cooled
Rated speed1800 rpm

Same engine, other brands

3 brands

The Isuzu 4LE2TAGV-03 in this set also powers 4 generator sets sold under 3 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
MagnumMLT4200IF4, MMG25IF4
Isuzu4LE2TAGV-03
John DeereMLG20IF4

Maintenance & consumables

for the Isuzu 4LE2TAGV-03
ItemSpecCapacityPart #Interval
Air filterDry type cartridge air filter—250 hr
Fuel filterFuel filter with replaceable element69858500 hr Amazon eBay $21.83 NAPA $15.34 FridayParts $36.28
Oil filterFull flow oil filter, spin on type6705703041000 hr Amazon eBay $16.89 PartsGeek $7.98 NAPA $9.09 FridayParts $20.19
BatteryClean Battery—1000 hr
BeltCheck Fan Belt Tension (Replace If Necessary)—1000 hr
CoolantCheck Coolant Level—250 hr
OilCheck Oil Level—250 hr
Spark plugReplace Air Filter Element—1000 hr

Compatible filters for the Isuzu 4LE2TAGV-03 — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.

  • Air filter: Generac OE3557 Generac OE3656 Isuzu 8972319000 Isuzu 5864014350 Isuzu 8972599390

Common questions

What is the power rating of the Generac MLT4200IF4?

The Generac MLT4200IF4 is rated 20 kW standby.

What engine does the Generac MLT4200IF4 use?

The Generac MLT4200IF4 is powered by the Isuzu 4LE2TAGV-03 engine.

What fuel does the Generac MLT4200IF4 use?

The Generac MLT4200IF4 runs on diesel.

What is the oil capacity of the Generac MLT4200IF4?

The Isuzu 4LE2TAGV-03 engine in the Generac MLT4200IF4 has an oil capacity of 10.4 liters.

How much coolant does the Generac MLT4200IF4 hold?

The Generac MLT4200IF4 cooling system holds 17 liters (4.5 US gallons) for the engine, per the manufacturer specification sheet.

What is the sound level of the Generac MLT4200IF4?

The Generac MLT4200IF4 is rated at 68.0 dBA at 7 m, per the manufacturer specification sheet.

What is the dry weight of the Generac MLT4200IF4?

The Generac MLT4200IF4 has a dry weight of 1033 kg (2277 lb).

What size fuel tank does the Generac MLT4200IF4 have?

The Generac MLT4200IF4 has a 194.5 liter (51 US gallon) fuel tank, giving about 48 hours of runtime.

What voltages is the Generac MLT4200IF4 available in?

The Generac MLT4200IF4 is offered in 120/240 V, Single-phase.

What battery does the Generac MLT4200IF4 use?

The Generac MLT4200IF4 uses 1 battery, 12 V each, 720 CCA, per the manufacturer specification sheet.

Which alternator is fitted to the Generac MLT4200IF4?

The Generac MLT4200IF4 uses a Marathon 334CSA3028 alternator.

What oil filter does the Generac MLT4200IF4 use?

The Generac MLT4200IF4 uses oil filter part number 670570304.

What fuel filter does the Generac MLT4200IF4 use?

The Generac MLT4200IF4 uses fuel filter part number 69858.

What air filter fits the Generac MLT4200IF4?

The Generac MLT4200IF4 uses air filter part numbers GENERAC OE3557, GENERAC OE3656.

Troubleshooting

39

Fault codes

CodeMeaning
Check Engine FaultA fault not recognized by the controller has been detected.
Low Oil PressureEngine oil pressure has fallen below its configured low oil pressure alarm level.
UnderspeedEngine speed has fallen below its configured underspeed alarm level.
OverspeedEngine speed has risen above its configured overspeed alarm level.
Low Fuel LevelEngine’s fuel level has fallen below its configured low fuel level alarm.
Battery Under/Over VoltageEngine’s DC supply has fallen below or risen above its configured alarm level.

Symptoms & remedies

SymptomCauseRemedy
Unit cranks, but will not startFuel level lowCheck fuel level in tank
Unit cranks, but will not startFuel flow obstructedVerify fuel pump operation
Unit cranks, but will not startFuel solenoid inoperableVerify fuel solenoid operation
Unit cranks, but will not startAir in fuel systemBleed air from fuel system
Unit cranks, but will not startRestricted air filterInspect air filter for blockage
Unit cranks, but will not startGlow plug(s) inoperableInspect fuel supply hose from tank to fuel filter for cracks and abrasion; Check for gelled fuel in fuel system in cold weather, especially at fuel filter; Refer to OEM engine operator's manual for additional information
Unit starts, but stumbles and diesAmbient temperature too lowCheck if ambient temperature is within unit limits
Unit starts, but stumbles and diesIntake heater inoperableCheck engine air inlet heater functionality
High coolant temperature shutdownLow coolant levelAllow engine to cool, then check coolant level in radiator. Add coolant if needed
High coolant temperature shutdownBlockage in radiatorInspect radiator surroundings for blockage and remove any foreign matter
High coolant temperature shutdownDebris on radiator faceInspect radiator surroundings for blockage and remove any foreign matter
High coolant temperature shutdownBroken coolant pump beltInspect for visible leaks. Verify tension of water pump drive belt
High coolant temperature shutdownCooling fan inoperableRemove load on generator and restart engine. Verify coolant temperature and shut engine down immediately if it starts to overheat
Low oil pressure shutdownOil level lowCheck oil level. Add oil if necessary
Low oil pressure shutdownOil pump inoperable
Unit stalls when export power is usedLoad exceeds unit ratingTurn outlet breaker ON and load sense switch OFF, confirm generator output is 60hz + or - 2hz. Reapply load
The lights are flashingDusk-to-dawn sensor adjustment neededAdjust the dusk-to-dawn sensor to increase or decrease light received
The lights are flashingGenerator frequency too lowTurn off main breaker; Check if AC frequency is >40hz
Mast Lights Off, Checking Outside the Control BoxLight fixture is too hotAllow light to cool 10-15 minutes before restarting
Mast Lights Off, Checking Outside the Control BoxFaulty lamp connectionCheck that the lamp is tight in the socket
Mast Lights Off, Checking Outside the Control BoxLamp brokenCheck for broken arc tube or outer lamp jacket, broken or loose components in lamp envelope, or blackening/deposits inside tube
Mast Lights Off, Checking Outside the Control BoxLoose lighting connectionsCheck the connections inside the mast junction box and each mast light housing/socket
Mast Lights Off, Checking Outside the Control BoxDamaged or loose electrical cordCheck the mast electrical cord for damage and check the cord connections inside the control box
Mast Lights Off, Checking Inside the Control BoxLoose lighting connectionsCheck the connections inside the control box and inside each ballast box
Mast Lights Off, Checking Inside the Control BoxGenerator output incorrectCheck the incoming voltage to the ballast by checking the available voltage on the GFCI receptacle. Incoming voltage should be 120V +/- 5V. If voltage is incorrect, the engine speed may need to be adjusted or generator may require service
Mast Lights Off, Checking Inside the Control BoxLow transformer outputThe voltage from the transformer should read approximately 400VAC as the light "strikes" (induces an arc), then drop and slowly rise back up to stabilize at 240-260VAC. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced
Mast Lights On But the Light Output is LowFixture and/or lens is dirtyClean reflective surface inside fixture and both inside and outside surface of glass lens. Use mild soap and water to clean lens. Other chemicals may have an adverse effect on the glass
Mast Lights On But the Light Output is LowLamp worn due to normal useReplace lamp
Mast Lights On But the Light Output is LowDamaged or loose electrical connectionsCheck the mast coil cord, mast junction box and mast light connections
Mast Lights On But the Light Output is LowGenerator output incorrectCheck the incoming voltage to the ballast. Incoming voltage should be 120V +/-5V. If the voltage is incorrect, the engine speed may need to be adjusted or the generator may require service
Mast Lights On But the Light Output is LowLow transformer outputThe voltage from the transformer should read approximately 400VAC as the light "strikes" (induces an arc), then drop and slowly rise back up to stabilize at 240-260VAC. On hard wired models, remove the mast junction box cover and insert the wire probes into the connector blocks for the light and ground. If proper voltage is not achieved, perform capacitor check to determine if the capacitor or coil needs to be replaced
One or more lights do not turn onLight breaker trippedCheck light breakers
One or more lights do not turn onLights not turned onCheck electronic control to see if lights are on; Turn lights on

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

4
Part #DescriptionQtySystem
01035Central Lift PointCentral lift point Amazon eBay
01144ControllerController Amazon eBay
90243Air Filter ElementAir filter Amazon eBay
209649Form: SFC626B1Service part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Continuous3.971.05
Continuous100%7.82.1
Prime5%3.971.05
Prime100%7.82.1

Available documents

Spec sheet (Generac)Reference (Magnum)Owner's manual — 37096 (Generac)

This page was generated from the 3 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Fuel filter 69858$15.34
Oil filter 670570304$7.98
2 priced items$23.32