Generac MGG350N2 Generator Set

The Generac MGG350N2 is a 259 kW (323 kVA) Natural Gas / LP Liquid standby generator set powered by a Power Solutions International D183TIC engine. It is available at 480/277 V, 3-phase, 60 Hz and rated 338 A. It holds about 11.1 L (2.9 gal) of oil and 44 L (11.6 gal) of coolant. Starting uses 2 group-8 batteries rated 900 CCA at 12 V. The set weighs about 12195 kg (26885 lb).

259 kW
Standby
18.27 L
Displacement
11.1 L
Oil capacity
2
Document types

How to read your Generac serial & model number →

Specifications

FuelNatural Gas / LP Liquid
Frequency60.0 Hz
Standby power259 kW
Standby kVA323
ControllerComAp digital controller
Oil capacity11.1 L
AlternatorStamford/AvK HCI434C-311, HCI434D-311
Voltage options480/277 V
Phase3
Rated current338 A
Power factor0.8
Circuit breaker600 A
Battery group8D
Battery crankingmin. 900 CCA CCA
Battery voltage12V (2), 24V series connection V
Battery quantity2
Coolant capacity44.0 L
Dry weight12195 kg

Engine

Power Solutions International D183TIC
Oil capacity11.1 L
Coolant capacity44.0 L
Displacement18.27 L
AspirationTurbo CAC
Rated speed1800 rpm

Maintenance & consumables

for the Power Solutions International D183TIC
ItemSpecCapacityPart #Interval
Coolant50/50 mix of coolant and water—
OilSAE 15W-40 low ash, API CD/CF or higher—250 hr
Spark plugGap 0.015 in (0.4 mm)—

Service intervals

1
ItemActionHoursMonthsNotes
Engine Oil and Filter (initial)Change50 hrFirst service — Initial oil and filter change after first 50 hours or first 3 months

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

1
TypeItemValueUnitCondition
GapSpark plug gap0.015in (0.4 mm)

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50/50 mix of coolant and waterMGG280N2 38 qt (43.2 L) incl. engine; MGG350N2 44 qt (50.0 L) incl. engine
Engine oilSAE 15W-40 low ashAPI CD/CF or higherMGG280N2 10.1 qt (38.1 L) incl. filter; MGG350N2 11.1 qt (42.1 L) incl. filter

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the Generac MGG350N2?

The Generac MGG350N2 is rated 259 kW standby (323.0 kVA).

What engine is in the Generac MGG350N2?

The Generac MGG350N2 is powered by the Power Solutions International D183TIC engine.

What kind of fuel does the Generac MGG350N2 run on?

The Generac MGG350N2 runs on Natural Gas / LP Liquid.

What's the oil capacity on a Generac MGG350N2?

The Power Solutions International D183TIC engine in the Generac MGG350N2 has an oil capacity of 11.1 liters.

What is the cooling system capacity of the Generac MGG350N2?

The Generac MGG350N2 cooling system holds 44 liters (11.6 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

How much does the Generac MGG350N2 weigh?

The Generac MGG350N2 has a dry weight of 12195 kg (26885 lb).

What voltage does the Generac MGG350N2 produce?

The Generac MGG350N2 is offered in 480/277 V, 3-phase.

What size battery does the Generac MGG350N2 need?

The Generac MGG350N2 uses 2 batteryies, 12V (2), 24V series connection V each, min. 900 CCA CCA, group 8D, per the manufacturer specification sheet.

What alternator comes on the Generac MGG350N2?

The Generac MGG350N2 uses a Stamford/AvK HCI434C-311, HCI434D-311 alternator.

Troubleshooting

6

Symptoms & remedies

SymptomCauseRemedy
Engine Cranks But Will Not StartNo fuelCheck that fuel valves are open
Engine Cranks But Will Not StartLow oil levelLow Oil Pressure Shutdown activated. Replenish oil to full
Engine Cranks But Will Not StartRestricted air flowCheck/replace air filter
Engine Cranks But Will Not StartNo sparkCheck/replace spark plug(s)
Engine Will Not Crank (Electric Start)Dead batteryRemove batteries and trickle charge. Never jump start. Even if only one battery is bad, it is recommended that both batteries be replaced at the same time
Engine Will Not Crank (Electric Start)Emergency stop is activatedReset controller after an emergency stop

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Generac MGG350N2 troubleshooting guide (43 entries) →

Fuel consumption

RatingLoadL/hgal/h
Prime50%196.0851.8
Prime75%279.3673.8
Prime100%358.194.6
Standby100%94.6425.0

Available documents