Specifications
| Fuel | Natural gas / propane dual fuel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 45 kW |
| Standby kVA | 50 |
| Prime power | 45 kW |
| Controller | PCC2100, PowerCommand 2100, PowerCommand PCC2100 |
| Oil capacity | 5.5 L |
| Voltage options | 12 V |
| Phase | 3-phase, 1-phase |
| Rated current | 375 A |
| Circuit breaker | 200 A |
| Battery group | 31 |
| Battery cranking | 625 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 26.1 L |
| Max ambient | 50.0 °C |
| Dimensions (L×W×H) | 2104×83×40 mm |
| Dry weight | 857 kg |
| Sound level | 67.0 dBA @ 7 m |
| Fuel tank | 270.2 L |
Maintenance & consumables
for the General Motors GM 5.0 L| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Tap filter on a flat surface to remove dirt; apply low pressure air source (30 psi) to inside of filter. Clean every 100 hours, more often in extremely dusty conditions. | — | 500 hr | ||
| Oil filter | Spin on by hand until gasket just touches mounting pad, then turn an additional 1/2 to 3/4 turn. Fill filter with clean lubricating oil. | — | 500 hr | ||
| Battery | Group 31, required battery voltage 12 Volts DC, CCA (minimum) 625 cold soak @ 0 deg F (-18 deg C). Battery ground negative. Corrected specific gravity 1.260 fully charged; charge if below 1.215. | — | 200 hr | ||
| Belt | Visually check belt for evidence of wear or slippage. Spring-loaded idler maintains correct belt tension. | — | 100 hr | ||
| Coolant | 50/50 coolant solution (50% pure water and 50% antifreeze). If temperatures below -37 deg F (-38 deg C) are possible, use 65% antifreeze and 35% water. Do not use antifreeze with anti-leak additives. Use clean, low-mineral soft water. | 26.1 L | — | 1000 hr | |
| Oil | API classification SJ, SH or SL. SAE 10W-30 recommended from 0 deg F (-18 deg C) or above; SAE 5W-30 if consistently below 0 deg F (-18 deg C); SAE 15W-40 for turbocharged engines or high ambient temperature installations | 5.5 L | — | 500 hr | |
| Spark plug | Spark plug gap 0.030 inch (0.762 mm). Lightly lubricate threads with high temp anti-seize compound. | — | 1000 hr |
Service intervals
18| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| coolant level | Check | 8 hr | Daily or after 8 hours | |
| engine oil level | Check | 8 hr | Daily or after 8 hours | |
| general set inspection | Inspect | 8 hr | Daily or after 8 hours. Check for oil, fuel, cooling and exhaust system leaks. Check exhaust system audibly and visually with set running. | |
| air cleaner (normal duty filter) | Check | 100 hr | 1 mo | Monthly or after 100 hours. Replace element after 500 hours. Perform more often in extreme duty conditions. |
| all hardware (fittings, clamps, fasteners, etc.) | Check | 100 hr | 1 mo | Monthly or after 100 hours |
| battery electrolyte level | Check | 100 hr | 1 mo | Monthly or after 100 hours |
| coolant heater(s) | Check | 100 hr | 1 mo | Monthly or after 100 hours |
| drive belt | Check | 100 hr | 1 mo | Visually check belt for evidence of wear or slippage. Replace if hard or brittle. |
| exterior of radiator for obstructions | Check | 100 hr | 1 mo | Monthly or after 100 hours |
| generator air outlet | Check | 100 hr | 1 mo | Monthly or after 100 hours |
| AC generator and controls | Check | 500 hr | Yearly or after 500 hours | |
| anti-freeze concentration | Check | 500 hr | Yearly or after 500 hours | |
| engine oil and filter (normal duty filter) | Change | 500 hr | 12 mo | Perform at least once a year. Perform more often in extreme duty conditions. |
| radiator hoses for wear and cracks | Check | 500 hr | Yearly or after 500 hours. Replace if hard or brittle. | |
| engine coolant port caps | Check | 1000 hr | Replace after 4 years or 1000 hours. | |
| radiator | Drain | 1000 hr | 24 mo | Drain and flush radiator - 2 years or after 1000 hours |
| spark plugs | Inspect | 1000 hr | Replace every 1000 hours. | |
| oxygen sensor | Test | 1500 hr | Must be performed by a qualified mechanic. Replace every 1,500 hours (recommended). |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
21| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Gap | Spark plug gap | 0.030 | inch | |
| Gap | Spark plug gap | 0.762 | mm | |
| Other | Battery specific gravity, charge the battery if below | 1.215 | ||
| Other | Battery specific gravity, fully charged (corrected) | 1.260 | corrected to 80 deg F (27 deg C) | |
| Other | Hydrometer specific gravity correction | 0.004 | for every ten degrees the electrolyte temperature is above 80 deg F (27 deg C) | |
| Other | Oil filter installation tightening after gasket contact | 1/2 to 3/4 | turn | after gasket just touches mounting pad |
| Pressure | Air filter cleaning maximum air pressure | 30 | psi | |
| Pressure | Exhaust Backpressure (Max. Allowed) | 20 | inch WC | |
| Pressure | Exhaust Connection size | 3 | inch NPT | |
| Pressure | Fuel flow inlet pressure (NG/LPG) minimum | 7.0 | inch H2O | |
| Pressure | Fuel flow inlet pressure NG/LPG Vapor Withdrawal maximum | 13.6 | inch H2O | |
| Pressure | LPG Liquid Withdrawal inlet pressure | 312 | psi | |
| Pressure | Radiator cleaning maximum pressure (low pressure compressed air or water) | 35 | psi | in opposite direction of normal air flow |
| Speed | Start cycles (default) | 3 | cycles | 15 seconds cranking and 15 seconds rest |
| Temperature | Engine jacket water coolant minimum to be maintained (NFPA 110) | 90 | deg F | |
| Temperature | Low coolant temperature warning trip | 21 | deg C | engine not operating |
| Temperature | Low coolant temperature warning trip (Engine Cold Code 1435) | 70 | deg F | engine not operating |
| Temperature | Maximum engine temperature before adding coolant | 120 | deg F | allow engine to cool below before adding coolant |
| Temperature | Minimum start temperature with engine jacket water coolant heaters | -25 | deg F | |
| Temperature | Recommended minimum ambient for standby gensets with engine jacket water coolant heaters (NFPA 110) | 40 | deg F | |
| Temperature | Screen Saver mode activation delay | 10 | minutes |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | 50/50 coolant solution (50% pure water and 50% antifreeze) | above -37°C | 26.1 L | If temperatures below -37 deg F (-38 deg C) are possible, use a mixture of 65% antifreeze and 35% water. Do not use antifreeze containing anti-leak additives. Use clean, low-mineral soft water. | |
| Engine oil | SAE 15W-40 | API classification SJ, SH or SL | Turbocharged engines, or engines in high ambient temperature installations. | ||
| Engine oil | SAE 5W-30 | API classification SJ, SH or SL | below -18°C | If ambient temperatures are consistently below 0 deg F (-18 deg C). | |
| Engine oil | SAE 10W-30 | API classification SJ, SH or SL | above -18°C | 5.5 L | Recommended for your engine from 0 deg F (-18 deg C) or above. |
| Fuel | Propane (Liquid or Vapor) or Natural Gas, or a combination of two fuels | Minimum inlet pressure NG/LPG 7.0 inch H2O (1.7 kPa); maximum NG/LPG Vapor Withdrawal 13.6 inch H2O (3.4 kPa); LPG Liquid Withdrawal 312 psi (2,153 kPa). |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
67| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 121 | Speed Signal Lost | Category A fault | Shutdown | |
| 135 | Oil Pressure Sensor H | Category C fault | Warning | |
| 141 | Oil Pressure Sensor L | Category C fault | Warning | |
| 143 | Pre-Low Oil Pres | Category D fault | Warning | Indicates the engine oil pressure has dropped to an unacceptable level. If the generator is powering critical loads and cannot be shut down, wait until the next shutdown period and then follow code 415 procedure. |
| 144 | Coolant Sensor High | Category C fault | Warning | |
| 145 | Coolant Sensor Low | Category C fault | Warning | |
| 146 | Pre-High Coolant Temp | Category D fault | Warning | Indicates the engine has begun to overheat (coolant temperature has risen to an unacceptable level). Reduce the load if possible by turning off non-critical loads. Check air inlets and outlets and remove any obstructions to airflow. If engine can be stopped, follow code 151 procedure. |
| 151 | High Coolant Temp | Category D fault | Shutdown | Indicates the engine has overheated (coolant temperature has risen above the shutdown trip point). Allow the engine to cool completely. Check the coolant level and replenish if low; look for coolant leaks. Check for obstructions to cooling airflow. Check fan belt and repair or tighten if necessary. Check the blower fan and circulation pumps on remote radiator installations. Reset the control and restart. |
| 197 | Low Coolant Level | Category D fault | Warning | Indicates engine coolant level has fallen to an unacceptable level. If the generator is powering critical loads and cannot be shut down, wait until the next shutdown period, and then follow 235 Coolant Level Alarm procedure. |
| 234 | Overspeed | Category A fault | Shutdown | |
| 235 | Low Coolant Level | Category D fault | Shutdown | Indicates engine coolant level has fallen below the alarm trip point. Allow the engine to cool down completely. Check the coolant level sight glass at LTA top tank and replenish if low. Look for possible coolant leakage points and repair if necessary. Reset the control and restart. |
| 359 | Fail To Start | Category D fault | Shutdown | Indicates a possible fuel system problem (engine cranks but fails to start). Open any closed fuel shutoff valve. Check for dirty or plugged air filter and replace if necessary. Fuel delivery to the set is inadequate - contact an authorized service center. Reset the control and restart. |
| 415 | Low Oil Pressure | Category D fault | Shutdown | Indicates engine oil pressure has dropped below the shutdown trip point. Check oil level, lines and filters. If the oil system is OK but oil level is low, replenish. Reset the control and restart. |
| 441 | Low Bat Voltage | Category D fault | Warning | Indicates battery voltage supply to the control is approaching a low level. Discharged or defective battery - check the battery charger fuse and recharge or replace the battery. Clean the battery cable terminals and tighten all connections. Check battery charge voltage float level if applicable (raise float level). |
| 442 | High Bat Voltage | Category D fault | Warning | Indicates battery voltage supply to the control is approaching a high level at which damage to the control can occur. Check the float level on the battery charger if applicable (lower float level). |
| 1123 | Shutdown After BS | Category A fault | Shutdown | |
| 1124 | Delayed Shutdown | Category E fault | Warning | |
| 1131 | Battle Sh Active | Category E fault | Warning | |
| 1311 | Customer Input #1 | Category E fault; optional customer selection | The nature of the fault is an optional customer selection (example inputs: Low Fuel Day Tank, Water In Fuel, Ground Fault). Programmable via the InPower service tool. | |
| 1312 | Customer Input #2 | Category E fault; optional customer selection | The nature of the fault is an optional customer selection. Programmable via the InPower service tool (default: Warning). | |
| 1313-1316 | Network Fault 1 through 4 | Category E fault | ||
| 1317 | Customer Input #3 | Category E fault; optional customer selection | The nature of the fault is an optional customer selection. Programmable via the InPower service tool (default: Warning). | |
| 1318 | Service Engine | Category B fault | Warning | Indicates that emissions criteria might not be met due to one of the following: engine running in open loop, lean mixture, rich mixture, or failed fuel system component. |
| 1334 | Crit Scaler OR | Category A fault | Shutdown | |
| 1335 | Noncrit Scaler OR | Category B fault | Warning | |
| 1416 | Failt to Shutdown | Category C fault | Warning | |
| 1417 | Pwr Down Error | Category D fault | Warning | Indicates that the control cannot power down due to some unknown condition. Possible drain on battery. Contact an authorized service center for service. |
| 1433 | Emergency Stop | Category D fault; indicates local Emergency Stop | Shutdown | To reset the local/remote Emergency Stop button: Pull the button out. Move the O/Manual/Auto switch to O. Press the front panel Fault Acknowledge/Reset button. Select Manual or Auto, as required. |
| 1434 | Remote E-stop | Category D fault; indicates remote Emergency Stop | Shutdown | See code 1433 to reset. |
| 1435 | Low Coolant Temp | Category D fault; warning occurs when the engine coolant temperature is 70 deg F (21 deg C) or lower | Warning | Indicates engine coolant heater is not operating or is not circulating coolant. Check that coolant heater is connected to power supply and for blown fuse or disconnected heater cord. Check for low coolant level and replenish; look for possible coolant leakage points and repair. |
| 1438 | Fail to Crank | Category D fault; possible fault with control, speed sensing or starting system | Shutdown | See code 441 for corrective action. |
| 1442 | Weak Battery | Category D fault; during cranking the battery voltage is at or below the weak battery warning trip point for a time greater than or equal to the weak battery set time | Warning | See code 441 for corrective action. |
| 1443 | Battery Failed | Category D fault; dead battery - engine will not start | Shutdown | See code 441 for corrective action. |
| 1444 | kW Overload | Category B fault | Warning | |
| 1445 | Short Circuit | Category A fault | Shutdown | |
| 1446 | High AC Voltage | Category A fault | Shutdown | |
| 1447 | Low AC Voltage | Category A fault | Shutdown | |
| 1448 | Under Frequency | Category D fault; possible fuel system problem or overload condition | Shutdown | Check for dirty or plugged air filter and replace if necessary. Check operation by disconnecting load and restarting generator set. Fuel system requires adjustment or fuel delivery is inadequate - contact an authorized service center. Reset the control and restart. |
| 1449 | Over Frequency | Category A fault | Warning | |
| 1452 | Gen CB Not Close | Category A fault | Warning | |
| 1453 | Gen CB Not Open | Category A fault | Warning | |
| 1459 | Reverse Power | Category A fault | Shutdown | |
| 1461 | Loss of Field | Category A fault | Shutdown | |
| 1466 | Modem Failure | Category C fault | Warning | |
| 1468 | Network Error | Category C fault | Warning | |
| 1469 | Speed/Hz Match | Category A fault | Shutdown | |
| 1471 | Over Current | Category B fault | Warning | |
| 1472 | Over Current | Category A fault | Shutdown | |
| 2323-2326 | Network Fault 5 through 8 | Category E fault | ||
| 2327 | PTC Fault | Category B fault | Warning | |
| 2329 | Low S1 Frequency | Category E fault | Warning | |
| 2331 | Low S1 Voltage | Category E fault | Warning | |
| 2335 | Excitation Fault | Category A fault | Shutdown | |
| 2336 | Memory Error | Category A fault | Shutdown | |
| 2337 | Pwr Tran Disabled | Category C fault | Warning | |
| 2338 | Pwr Tran Failure | Category C fault | Warning | |
| 2339 | Pwr Down Enabled | Category E fault | Warning | |
| 2341 | High Control Temp | Category B fault | Warning | |
| 2342 | Too Long in Idle | Category E fault; generator set has been in Idle mode too long (10 minutes maximum) | Warning | Indicates the generator set has been in Idle mode too long (10 minutes maximum). |
| 2358 | High S1 Voltage | Category E fault | Warning | |
| 2396 | S1 CB Not Close | Category E fault | Warning | |
| 2397 | S1 CB Not Open | Category E fault | Warning | |
| 2966 | PTC Timeout | Category C fault | Warning | |
| 2967 | Governor Fault | Category C fault | Warning | |
| 2968 | AVR Fault | Category C fault | Warning | |
| 2969 | LON Failure | Category C fault | Warning | |
| 2972 | Field Overload | Category A fault | Shutdown |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Adjusting Values/Parameters (Adjust Menu) adjustment
Tools: InPower Service Tool
- Press the button next to the arrow symbol until the + and - symbols are displayed.
- If necessary, press the button next to the symbols to move to the numeric character to change.
- Press + to increase the value or select parameter; press - to decrease or select parameter.
- Press the arrow symbol to save changes (cursor on last numeric character when adjusting values).
Vibration Isolator Installation installation
⚠ Ensure that the equipment is stable before installation of the vibration isolator.
- Place the vibration isolator under the support point of the equipment, ensure load is uniformly distributed over the top plate.
- With the 6 mm spacer in position, tighten the positioning nut.
- Turn the adjusting bolt of the spring counter-clockwise to load the spring.
- Load all the FSR at the same time to ensure the total load is uniformly spread.
- Continue until the spring load equals the load of the equipment.
- When equilibrium point is reached, the 6 mm spacer can be removed from the FSR mount.
Checking Specific Gravity maintenance
Tools: Battery hydrometer
- Use a battery hydrometer to check the specific gravity of the electrolyte in each battery cell.
- Hold the hydrometer vertical and take the reading.
- Correct the reading by adding four gravity points (0.004) for every ten degrees the electrolyte temperature is above 80 deg F (27 deg C).
- A fully charged battery will have a corrected specific gravity of 1.260.
- Charge the battery if the reading is below 1.215.
Cleaning Batteries maintenance
⚠ Electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. Wear goggles and protective rubber gloves and apron.
- Keep the batteries clean by wiping them with a damp cloth whenever dirt appears excessive.
- If corrosion is present around the terminal connections, remove battery cables.
- Wash the terminals with a solution consisting of 1/4 pound of baking soda added to 1 quart of water.
- Be sure the vent plugs are tight to prevent cleaning solution from entering the cells.
- After cleaning, flush the outside of the battery and surrounding areas with clean water.
- Coat the terminals with a light application of petroleum jelly or non-conductive grease to retard corrosion.
Draining and Flushing the Cooling System maintenance
⚠ The heater element will burn out if engine coolant is removed with heater connected to power source.
- Disconnect engine coolant heater from power source (if equipped).
- Allow the engine to cool and then remove radiator pressure cap.
- Open the radiator drain cock and remove the water drain plugs (one on each side of engine).
- When the coolant is drained, place the end of a water hose into the radiator filler and turn on water supply.
- Regulate the flow of water until it equals the outflow from drain openings; continue flushing until outflow is clear of rust sediment.
- If equipped with engine coolant heater, drain coolant by removing hose and clamp from bottom of heater.
- Replace the water drain plugs and close the radiator drain cock when flushing is complete.
- Refill the cooling system with the recommended coolant.
Engine Oil Change maintenance
⚠ Hot crankcase oil can cause burns if it is spilled or splashed on skin.
⚠ Contact with used engine oil can cause cancer or reproductive toxicity.
- Run engine until thoroughly warm before draining oil.
- Stop the set, place a pan under the drain outlet.
- Remove the oil drain plug or open the drain valve.
- After the oil is completely drained, replace the drain plug or close the drain valve.
- Refill with oil of the correct API viscosity grade for the temperature conditions.
Filling the Cooling System maintenance
⚠ Do not add cold coolant to a hot engine. Allow the engine to cool to below 120 deg F (50 deg C) before adding coolant.
- Check that all drain cocks are closed and all hose clamps secure.
- Open bleeder valve.
- Remove the radiator pressure cap and slowly fill the cooling system with the recommended coolant.
- When the coolant begins to flow from the engine bleeder valve, close the valve and continue filling the radiator.
- When the engine is first started, remove the pressure cap and monitor the coolant level.
- As trapped air is expelled, add coolant; replace the pressure cap when the coolant level is stable.
Oil Filter Change maintenance
- Spin off oil filter and discard it in accordance with local environmental regulations.
- Thoroughly clean filter mounting surface.
- Apply a thin film of oil to filter gasket and install new element.
- Spin element on by hand until gasket just touches mounting pad and then turn an additional 1/2 to 3/4 turn.
- Fill the oil filter with clean lubricating oil by pouring oil into the center hole of the filter.
- With oil in crankcase, start engine and check for leaks around filter element.
- Retighten only as much as necessary to eliminate leaks but do not overtighten.
Preparing Set for Storage maintenance
- Exercise the set as described in the operation section until the engine is up to operating temperature.
- Shut down the engine.
- Turn off and disconnect battery charger (if equipped).
- Disconnect the battery (negative cable first) and store in a cool, dry place; connect to charger every 30 days.
- Drain the engine oil while still warm and refill with new oil recommended for set; attach a tag indicating type of oil used.
- Remove the spark plugs and pour two ounces of rust preventative oil into each spark plug opening; crank the set for five seconds and replace the spark plugs.
- Disconnect engine coolant heater from power source (if equipped).
- Drain the cooling system including the engine block.
- Remove the air cleaner and seal off the carburetor air inlet opening and the PVC hose.
- Plug the exhaust outlets to prevent entrance of moisture, bugs, dirt, etc.
- Clean and wipe entire unit; coat parts susceptible to rust with a light coat of oil; cover entire set loosely after engine has cooled down.
Returning Set to Service maintenance
- Remove protective cover.
- Remove exhaust plugs, seal from carburetor and PVC hose and replace air cleaner.
- Check oil dipstick to make sure crankcase is full.
- Refill cooling system.
- Reconnect the battery (positive cable first) and check specific gravity.
- Connect the battery charger (if applicable).
- Connect engine coolant heater to power supply (if applicable).
- Remove all loads before starting set.
- Start set and apply load of at least 50% of nameplate rating.
- Check all gauges for normal readings. Set is now ready for service.
Spark Plug Inspection maintenance
- Remove the spark plugs and inspect for damaged or cracked insulators, worn electrodes, or excessive carbon deposits.
- Replace the spark plug if any of these conditions are noted.
- Clean those plugs that can be reused and regap to the amount specified in the Specifications section.
- Clean all dirt and grit away from the spark plug seats.
- Lightly lubricate spark plug threads with high temp anti-seize compound.
Adjusting Values/Parameters operation
⚠ Enabling Idle Start will cause the generator set to run in idle mode until Idle Start is disabled. A warning is displayed if generator set is left in idle more than 10 minutes. Long periods of engine idling can eventually affect engine performance and may void engine warranty.
- Press the button next to the > symbol in the display until the + and - symbols are displayed.
- If necessary, press the button next to the symbols to move to the numeric character you wish to change.
- Press the button next to the + symbol to increase the value; press the button next to the - symbol to decrease the value.
- After adjusting values, press the > symbol to save the changes (cursor must be on the last numeric character).
- If the Home button or Previous Main Menu button is pressed before the > symbol, the changes are not saved.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What size generator is the Cummins/Onan GGPC?
The Cummins/Onan GGPC is rated 45 kW standby (50.0 kVA).
Which engine powers the Cummins/Onan GGPC?
The Cummins/Onan GGPC is powered by the General Motors GM 5.0 L engine.
What fuel type does the Cummins/Onan GGPC take?
The Cummins/Onan GGPC runs on Natural gas / propane dual fuel.
What is the oil capacity of the Cummins/Onan GGPC?
The General Motors GM 5.0 L engine in the Cummins/Onan GGPC has an oil capacity of 5.5 liters.
How much coolant does the Cummins/Onan GGPC hold?
The Cummins/Onan GGPC cooling system holds 26.1 liters (6.9 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
How loud is the Cummins/Onan GGPC?
The Cummins/Onan GGPC is rated at 67.0 dBA at 7 m, per the manufacturer specification sheet.
How much does the Cummins/Onan GGPC weigh?
The Cummins/Onan GGPC has a dry weight of 857 kg (1889 lb).
What size fuel tank does the Cummins/Onan GGPC have?
The Cummins/Onan GGPC has a 270.2 liter (71 US gallon) fuel tank.
What voltages is the Cummins/Onan GGPC available in?
The Cummins/Onan GGPC is offered in 12 V, 3-phase, 1-phase-phase.
What size battery does the Cummins/Onan GGPC need?
The Cummins/Onan GGPC uses 1 battery, 12 V each, 625 CCA, group 31, per the manufacturer specification sheet.
Troubleshooting
6Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| Engine Lacks Power or Is Unstable (No Fault Message) — The engine is approaching a level at which unpredictable operation may occur. | Current ambient conditions cause a derate, limiting power to less than the rated power. | Determine proper derates for ambient conditions. Refer to specification sheet for site derating factors. |
| Engine Lacks Power or Is Unstable (No Fault Message) — The engine is approaching a level at which unpredictable operation may occur. | The engine air filter element is dirty. | Replace the air filter element. |
| Engine Lacks Power or Is Unstable (No Fault Message) — The engine is approaching a level at which unpredictable operation may occur. | Check for exhaust restrictions. | See the Installation Manual. |
| Engine Lacks Power or Is Unstable (No Fault Message) — The engine is approaching a level at which unpredictable operation may occur. | The gaseous fuel is of insufficient energy content or fuel pressure. | Check with the propane supplier or the gas utility to confirm the energy content of the gaseous fuel being used. Propane must have approximately 2500 BTU's per cubic foot and natural gas 1000 BTU's per cubic foot. Check the gas supply pressure (7.0 to 13.6 inches WC) and readjust it if necessary. |
| Engine Lacks Power or Is Unstable (No Fault Message) — The engine is approaching a level at which unpredictable operation may occur. | LPG liquid converter frosts. | Check for low coolant and fill if necessary. Check for air in the cooling system and, if necessary, bleed the cooling system. |
| Engine Lacks Power or Is Unstable (No Fault Message) — The engine is approaching a level at which unpredictable operation may occur. | Incorrect demand regulator adjustment. | Refer to Initial Demand Regulator Adjustment. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Cummins/Onan GGPC troubleshooting guide (156 entries) →
Repair guides
7- Adjusting Values/Parameters
- Belt Removal
- Belt Replacement
- Cleaning Batteries
- Draining and Flushing the Cooling System
- Spark Plug Inspection
- Vibration Isolator Installation
Step-by-step procedures compiled from the Cummins/Onan service manual for this model.
Parts
7| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 0193-0529 | Temperature Sensor (Engine Coolant Ports - Location A, item 3) | Sensor | eBay | |
| A026K935 | 5/8 ID Hose (Engine Coolant Ports - Location B) | Hose | eBay | |
| A026K943 | 5/8 Beaded Hose x 3/8 MPT Fitting (Engine Coolant Ports - Location B) | Hose | eBay | |
| 0504-0003 | Bleeder Valve (Engine Coolant Ports - Location A, item 2) | Service part / kit | eBay | |
| 0505-0018 | Reducer bushing (Engine Coolant Ports - Location A, item 1) | Service part / kit | eBay | |
| 0505-0019 | Bushing-Reducer | 1 | Service part / kit | Amazon eBay |
| A026K939 | 3/8 FPT Brass Cap (Engine Coolant Ports - Location B) | Service part / kit | eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 312.0 | 45.6 | |
| Prime | 25% | 11.73 | 3.1 |
| Prime | 50% | 16.66 | 4.4 |
| Prime | 75% | 22.33 | 5.9 |
| Prime | 100% | 28.01 | 7.4 |
| Standby | 7.0 | 1.8 |
Available documents
This page was generated from the 7 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.