HomeCaterpillarCaterpillar 3508

Caterpillar 3508 Generator Set

The Caterpillar 3508 is a 620 kW (641 kVA) diesel standby generator set powered by a Caterpillar 3508B engine. It is available at 480 V, 3-phase, 60 Hz and rated 962 A. It holds about 104 L (27.5 gal) of oil and 285 L (75.3 gal) of coolant, with a maximum ambient rating of 80 °C. The set measures 2136×1703×1720 mm (84.1×67.0×67.7 in) and weighs about 4318 kg (9520 lb).

620 kW
Standby
34.5 L
Displacement
104.0 L
Oil capacity
6
Document types

How to read your Caterpillar serial & model number →

Service parts for the 3508

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Fuel system

1 required

Oil system

1 required

Belts

1 required

Cooling system

1 required

Electrical

1 required

Hydraulic system

1 required
1R0741Hydraulic filter$22.00eBay

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Fueldiesel
Frequency60.0 Hz
Standby power620 kW
Prime power485 kW
EmissionsTier 1, Stage I
ControllerADEM A3
Oil capacity104.0 L
AlternatorSR4
Voltage options600 V
Phase3 phase
Rated current962 A
Power factor1
Coolant capacity285 L
Max ambient80 °C
Dimensions (L×W×H)2136×1703×1720 mm
Dry weight10136 kg

Engine

Caterpillar 3508B
Oil capacity397.0 L
Coolant capacity103.0 L
Displacement34.5 L
AspirationTA
Rated speed1800 rpm

Maintenance & consumables

for the Caterpillar 3508B
ItemSpecCapacityPart #Interval
Air filterAir filter inner106-3973 Amazon $39.31 eBay $79.98 eBay $39.31 FridayParts $62.16
Fuel filterFilter fuel1R0755 Amazon $20.99 eBay $34.99 eBay $96.90 KuduParts $54.00 FridayParts $71.99
Oil filterFilter oil1R0716 Amazon $52.99 eBay $44.90 eBay $44.90 KuduParts $80.00 FridayParts $81.99
Battery245-5829 Amazon eBay $98.00
BeltV-belt141-7116 eBay $31.99 FridayParts $22.60
Coolant9S-8140 Amazon eBay
Hydraulic filterFilter hydraulic1R0741 eBay $22.00
OilCF-4644.0 L1000 hr
Spark plug

Service intervals

40
ItemActionHoursMonthsNotes
SystemTest1 hrToCI quarterly: exercise system under full load for 1 hour
Battery Electrolyte LevelCheck250 hrEvery 250 Service Hours
BeltsInspect250 hrInspect/Adjust/Replace; Every 250 Service Hours
Cooling System Coolant Sample (Level 1)Other250 hrObtain; Every 250 Service Hours
Cooling System Supplemental Coolant Additive (SCA)Test250 hrTest/Add; Every 250 Service Hours
Engine Oil SampleOther250 hrObtain; Every 250 Service Hours
Engine Oil SampleTest250 hrEvery 250 Service Hours - Obtain
Engine Valve LashAdjust4000 hrFirst service — Inspect/Adjust; Initial 250 Service Hours
Fan Drive BearingLubricate250 hrEvery 250 Service Hours
Fuel InjectorAdjust4000 hrFirst service — Inspect/Adjust; Initial 250 Service Hours
Hoses and ClampsInspect250 hrInspect/Replace; Every 250 Service Hours
RadiatorClean250 hrEvery 250 Service Hours
Speed SensorClean250 hrFirst service — Initial 250 Service Hours (Prime Power) - Clean/Inspect
Air ShutoffTest500 hrEvery 500 Service Hours (Prime Power)
Cooling System Coolant Sample (Level 1)Test500 hrEvery 500 Service Hours (Prime Power)
Cooling System Coolant Sample (Level 2)Test500 hrFirst service — Initial 500 Hours for new, refilled and converted systems
Engine Oil and FilterChange500 hrEvery 500 Service Hours - standard sump; deep sump every 1000 hours
Magnetic PickupsClean500 hrFirst service — Clean/Inspect; Initial 500 Service Hours or at first oil change
Cooling System Coolant Sample (Level 2)Other1000 hrObtain; Every 1000 Service Hours
EngineClean1000 hrEvery 1000 Service Hours
Engine Crankcase BreatherClean1000 hrEvery 1000 Service Hours
Engine Protective DevicesCheck1000 hrEvery 1000 Service Hours
Engine Protective DevicesTest1000 hrCheck; Every 1000 Service Hours
Fuel System Primary FilterReplace1000 hrEvery 1000 Service Hours - Clean/Inspect/Replace
Fuel System Secondary FilterReplace1000 hrEvery 1000 Service Hours
Generator Winding InsulationTest1000 hrEvery 1000 Service Hours
Rotating RectifierInspect1000 hr12 moEvery 1000 Service Hours or 1 Year - Inspect/Test
Crankshaft Vibration DamperInspect2000 hrEvery 2000 Service Hours
Engine MountsCheck2000 hrEvery 2000 Service Hours
GeneratorOther2000 hr6 moEvery 2000 Service Hours or 6 Months - Dry
Generator Set VibrationTest2000 hrEvery 2000 Service Hours - Test/Record
Stator LeadCheck2000 hr6 moEvery 2000 Service Hours or 6 Months
TurbochargerInspect2000 hrEvery 2000 Service Hours
Cooling System Coolant (DEAC)Change3000 hr36 moEvery 3000 Service Hours or 3 Years
Cooling System Coolant Extender (ELC)Other3000 hr36 moEvery 3000 Service Hours or 3 Years - Add
Air Shutoff DamperCheck6000 hrEvery 6000 Service Hours - Remove/Check
AlternatorInspect6000 hr72 moEvery 6000 Service Hours or 6 Years
Cooling System Coolant (ELC)Change6000 hr72 moEvery 6000 Service Hours or 6 Years
Cooling System Water Temperature RegulatorReplace6000 hr72 moEvery 6000 Service Hours or 6 Years
Prelube PumpInspect6000 hr72 moEvery 6000 Service Hours or 6 Years

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAir shutoff damper plunger distance A (minimum)18.3mm0.72 inch; replace plunger if less
ClearanceCoolant level below bottom of filler pipe13mmno sight gauge
GapAir shutoff damper plunger distance A (replace if less)18.3mm
OtherAir cleaner element cleaning limitsix timesreplace at least once per year regardless
OtherAltitude capability without derate1525m
OtherAltitude capability without derate800m
OtherCoolant Sample (Level 1) interval for Cat DEAC250hours
OtherCooling system cleaner amount (heavy deposits)0.5L per 3.8 to 7.6 L capacity1 pint per 1 to 2 US gal
OtherCooling system cleaner amount (normal deposits)0.5L per 15 L capacity1 pint per 4 US gal
OtherCooling system cleaning duration (heavy deposits)90minutesminimum, coolant at least 82 C (180 F)
OtherCooling system cleaning duration (normal deposits)30minutesminimum, coolant at least 82 C (180 F)
OtherCooling system fill rate maximum19L/min
OtherDamper fluid viscosity degradation limit20percentmajority of applications
OtherDamper fluid viscosity degradation limit (Hasse & Wrede)20percentmajority of applications
OtherDamper operating hours before rebuild/replace (damper without sampling port)20000hours
OtherDamper without sampling port - rebuild/replace interval20000hoursor at major overhaul
OtherExercise under full load1hourToCI quarterly
OtherFast Acting Cooling System Cleaner amount0.5 L per 15 LLcooling system capacity, normal deposits
OtherFast Acting Cooling System Cleaner amount0.5 L per 3.8 to 7.6 LLcooling system capacity, heavy deposits
OtherFull load test duration4hoursOnce per year
OtherGross Input Torque (TH55-E70)12 667N•m (9350 lb-ft)
OtherGross Input Torque (TH55-E90)12 677N•m (9350 lb-ft)
OtherHydrosolv cleaner concentration2 to 5percenttemperatures up to 93 C (200 F)
OtherLoad bank data recording interval15minutesDuring load bank test
OtherLoad bank test load level80% of generator nameplate capacity4-hour resistive load bank test
OtherLoad bank test profile2 hours at 50%, 1 hour at 75%, 1 hour at 100%Annual four (4) hour load bank test
OtherMaximum air pressure at nozzle for cleaning purposes205kPa30 psi
OtherNew drive belt tension recheck after operation30minutesrated rpm
OtherRating condition (diesel 7 L and higher)99 kPa (29.31 in Hg) dry barometer, 25°C (77°F)SAE J1995 inlet air standard
OtherRating condition (diesel up to 6.6 L)100 kPa (29.5 in Hg) total barometric pressure, 1 kPa (.295 in Hg) vapor pressure, 25°C (77°F)ISO/TR14396 inlet air standard
OtherRating condition (gas)100 kPa (29.61 in Hg) and 25°C (77°F)SAE J1349 standard
OtherStall Torque Ratio (TH55-E70)2.23
OtherStall Torque Ratio (TH55-E90)2.23
OtherStarting motor cool-down between cranking periods2minutes
OtherSupplemental coolant additive concentration maximum (conventional coolant)6percent
OtherSupplemental coolant additive concentration maximum (water and SCA)8percent
OtherThread lock cure time minimum before air shutoff use1hour
PressureAir cleaner service indicator restriction (clean/replace)6kPa25 inches of H2O
PressureEngine air cleaner differential pressure (nominal)3kPanormal engine operation
PressureEngine air cleaner maximum differential pressure (replace element)6.2kPa
PressureEngine oil filter differential pressure (nominal)60kPanormal engine operation
PressureEngine oil filter differential pressure (normal)60kPanormal engine operation
PressureEngine oil filter differential pressure (replace elements)103kPaoil filter elements to be replaced
PressureEngine oil pressure during cranking70kPacranking with fuel off
PressureFuel filter differential pressure (nominal)60kPanormal engine operation
PressureFuel filter differential pressure (normal)60kPanormal engine operation
PressureFuel filter differential pressure (replace secondary elements)103kPafuel filter elements to be replaced
PressureMaximum air pressure at nozzle for cleaning205kPa
PressureMaximum air pressure for cleaning (aftercooler core)205kPa30 psi; at nozzle
PressureMaximum air pressure for cleaning (radiator)205kPa30 psi; deadheaded nozzle
PressureMaximum air pressure for cleaning air cleaner element207kPa30 psi
PressureMaximum water pressure for cleaning (aftercooler core)275kPa40 psi
PressureOil pressure required before starting after oil change70kPa10 psi; crank with fuel off, max 30 seconds
PressureUnit injector fuel injection pressure1240bar (18 000 psi)
PressureWS255 pump plunger load238,000lb (107,960 kg)
PressureWS273XD pump plunger load275,000lb (124 738 kg)
PressureWS305XD pump plunger load250,000lb (113 398 kg)
ResistanceExciter field L1 resistance - 1400 Frame11ohmsapproximation, winding at room temperature
ResistanceExciter field L1 resistance - 1600 Frame10ohmsapproximation, winding at room temperature
ResistanceExciter field L1 resistance - 1800 Frame10.9ohmsapproximation, winding at room temperature

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantCat DEACDiesel; 3,000 Service Hours or Three Years; annual S·O·SSM Level 2 coolant sampling and analysis
CoolantCat DEAC (Diesel Engine Antifreeze/Coolant)Conventional coolant; SCA required; see SEBU6251
CoolantCat ELCDiesel; 12,000 Service Hours or Six Years; add Cat ELC Extender at 6,000 service hours or one half of service life; annual S·O·SSM Level 2 coolant sampling and analysis
CoolantCat ELC (Extended Life Coolant)Add Cat ELC Extender once; do not use conventional SCA with Cat ELC
CoolantCat ELC ExtenderNeeds to be added only once; add per cooling system capacity
CoolantCat NGECNatural Gas; 16,000 Service Hours or Three Years; use interval that occurs first
CoolantCommercial long life / heavy-duty coolant meeting Caterpillar EC-1Caterpillar Engine Coolant Specification -1 (EC-1)Obtain Level 1 coolant sample
CoolantCommercial long life coolant meeting Caterpillar EC-1Caterpillar Engine Coolant Specification -1 (EC-1)
CoolantSupplemental Coolant Additive (SCA)Max 6 percent with conventional coolant; max 8 percent with water and SCA
Engine oilEPA 2D 89.330-96 (fuel reference, Diesel <6.6 L, density 0,845-0,850 kg/L a 15 °C)Reference condition only, not a lubricant recommendation
Engine oilCat NGEONatural Gas
Engine oilair tool oilbelow 0°CAir starting motor lubricator; temperatures below 0 C (32 F)
Engine oillow sulfated ash oilRequired for U.S. EPA Tier 4 Final, EU Stage IV engines.
Engine oilmeeting manufacturer's specsAdd crankcase oil (grade meeting manufacturer's specs) to correct level (SCI)
Engine oilCat Arctic DEO SYN SAE 0W-30-40°C to 30°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SYN SAE 5W-40-30°C to 50°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SAE 10W-30-18°C to 40°CEngine Crankcase; Industrial Engines
Engine oilCat DEO SAE 15W-40-9°C to 50°CEngine Crankcase; Industrial Engines
Engine oilnondetergent SAE 10Wabove 0°CAir starting motor lubricator; temperatures greater than 0 C (32 F)
FuelUltra Low Sulfur Diesel (ULSD)Contains less than or equal to 15 parts per million sulfur (mg/kg); required for U.S. EPA Tier 4 Final, EU Stage IV engines. B20 biodiesel capability available.
Fuel35° API gravity at 60°F (16°C)LHV 18,390 Btu/lb (42 780 kJ/kg)Fuel at 85°F (29°C) weighing 7.001 lbs/U.S. gal (838.9 g/liter)
Fuel35° API gravity, LHV 42 780 kJ/kg (18,390 btu/lb)SAE J1995Diesel engines 7 liter and higher; used at 29°C (84.2°F) with density 838.9 g/L
FuelEPA 2D 89.330-96EPA 2D 89.330-96Diesel engines up to 6.6 liter; density 0.845-0.850 kg/L @ 15°C (59°F); fuel inlet temperature 40°C (104°F)
FuelNo. 2 fuel3600 engines designed for 80 000 hours on No. 2 fuel; ratings based on API gravity of 35 at 15 C (60 F), LHV of 42 780 kJ/kg used at 29 C (84 F) with a density of 838.9 g/L
Fueldry natural gas, LHV 35.54 MJ/Nm3 (905 btu/ft3)Gas ratings based on SAE J1349 standard conditions of 100 kPa (29.61 in Hg) and 25°C (77°F)
GreaseCat Generator Set GreasePart Number 108-8611
GreaseEA6-40°C to 80°CNon-regreasable bearings 311-0843/311-0844
GreaseMobilith SHC220-40°C to 80°C2.8 gRoller bearings 139-0349/139-0350; every 250 service hours
Grease2S-3230 Bearing Lubricant-29°C to 80°C51.2 gGenerator bearings; 59 mL (2 oz); every 2000 service hours or 12 months
GreaseUNIREX N3-29°C to 60°CDo not exceed 60 °C (140 °F) above ambient; some bearings non-regreasable

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Belts - Adjusting the Alternator Belt adjustment
  1. Remove the drive belt guard.
  2. Loosen mounting bolt (1), adjusting nuts (2) and mounting bolt (3).
  3. Turn adjusting nuts (2) to increase or decrease drive belt tension.
  4. Tighten adjusting nuts (2), mounting bolt (3), and mounting bolt (1).
  5. Reinstall the drive belt guard.
  6. If new belts installed, recheck tension after 30 minutes at rated rpm.
Belts - Inspect/Adjust/Replace adjustment

⚠ Slippage of loose belts can reduce efficiency of driven components

⚠ Too tight belts place unnecessary stress on components

  1. Remove the drive belt guard.
  2. Loosen mounting bolt, adjusting nuts and mounting bolt.
  3. Turn adjusting nuts to increase or decrease drive belt tension.
  4. Tighten adjusting nuts and both mounting bolts to proper torque.
  5. Reinstall the drive belt guard.
  6. If new drive belts are installed, recheck tension after 30 minutes.
Air Shutoff - Test (ADEM II Engine Control Modules) diagnostic

⚠ Check the wiring for the air shutoff switches, and for the solenoids

  1. Do not start the engine; ensure engine control is OFF.
  2. Verify both air shutoff gates latched OPEN and switches connected.
  3. Turn panel power ON; gates should remain open.
  4. Activate EMERGENCY STOP; both gates should close.
  5. Reset; latch only right gate; power ON; right gate should close.
  6. Latch only left gate; power ON; left gate should close.
  7. Operate engine normally; ensure gates remain latched.
Generator Winding Insulation - Test diagnostic

⚠ High voltage can cause electrocution. Discharge instrument leads and generator windings.

Tools: 300-8648 Insulation Testing Gp

  1. Take the generator out of service.
  2. Visually inspect generator for moisture. If moisture exists, dry the unit first.
  3. Inspect installation. Determine equipment that will be tested.
  4. Discharge capacitance of the windings. Disconnect 'T0' from ground.
  5. Disconnect sensing lead wires for regulator and PT leads of load share module.
  6. Connect insulation tester Black lead to ground; RED lead to 'T0'.
  7. Set voltage to rated voltage. Apply voltage; observe readings at 30 and 60 seconds.
  8. Record 60 second reading (correct for temperature), temperature, and humidity.
Aftercooler Core - Inspect/Clean maintenance

⚠ Do not use a high concentration of caustic cleaner

⚠ Do not use high pressure when the fins are cleaned

  1. Remove the core.
  2. Turn the aftercooler core on one side; remove accessible debris.
  3. Back flush the core with cleaner.
  4. Remove the drain plug; steam clean the core; flush the fins.
  5. Wash the core with hot, soapy water.
  6. Flush thoroughly with clean, fresh water until clear.
  7. Dry the core with compressed air opposite to normal flow direction.
  8. Inspect O-rings/seals; pressure test for leaks; install the core.
Automatic Transfer Switch Semi-Annual Service maintenance
  1. Verify proper operation of exerciser clock; adjust if necessary.
  2. Provide visual inspection of all contacts and connection points.
  3. Perform building load test if practical and inspect for proper transfer and re-transfer.
  4. Verify operation of all control lamps.
Batteries - Replace maintenance

⚠ Batteries give off combustible gases which can explode; ensure proper ventilation.

⚠ Always recycle a battery; never discard a battery.

  1. Turn key start switch OFF. Remove key and all electrical loads.
  2. Turn OFF battery charger. Disconnect the charger.
  3. Disconnect NEGATIVE '-' cable from NEGATIVE battery terminal.
  4. Disconnect POSITIVE '+' cable from POSITIVE battery terminal.
  5. Remove the used battery. Install the new battery.
  6. Connect starting motor cable to POSITIVE '+' battery terminal.
  7. Connect ground plane cable to NEGATIVE '-' battery terminal.
Battery and Battery Charger System Semi-Annual Service maintenance
  1. Clean all battery terminals; verify integrity of cables and connectors.
  2. Load-test battery.
  3. Measure specific gravity of each battery cell.
  4. Inspect electrolyte level and add fluid if necessary.
  5. Verify proper operation and float voltage of external battery charger.
  6. Verify and record output of engine alternator.
Controls Semi-Annual Service maintenance
  1. Verify and record output voltage and adjust voltage regulator, if necessary.
  2. Calibrate control meters.
  3. Verify and record output frequency and adjust governor, if necessary.
  4. Verify operation of all control panel lamps.
  5. Inspect for any loose connections, terminals or discoloration.
Coolant System Semi-Annual Service maintenance
  1. Inspect all clamps, verify condition of all hoses and identify any leaks.
  2. Verify proper operation of engine water jacket heater.
  3. Test coolant freeze point and verify coolant level.
  4. Test coolant additive package for proper corrosion inhibitors.
  5. Inspect belt condition and tension; correct as required.
  6. Inspect radiator core for visual blockage or obstructions.
  7. Inspect for proper operation of intake louvers.
  8. Verify proper operation of remote radiator and belt condition.
Cooling System Coolant (DEAC) - Change maintenance

⚠ Hot coolant can cause serious burns

⚠ Use only cooling system cleaners approved for Caterpillar engines

Tools: 9S-8140 Pressurizing Pump

  1. Stop engine, allow to cool, relieve pressure, remove filler cap.
  2. Open drain valves or remove drain plugs; drain coolant.
  3. Flush cooling system with clean water.
  4. Close drains; fill with water and Fast Acting Cooling System Cleaner.
  5. Operate engine 30 minutes with coolant temperature at least 82 C.
  6. Stop, cool, drain; flush with clean water until clear.
  7. Fill with coolant/antifreeze; do not install filler cap.
  8. Run engine to purge air; check level; install cap.
Cooling System Coolant (ELC) - Change maintenance

⚠ Use only clean water to flush the cooling system when ELC is drained

Tools: 9S-8140 Pressurizing Pump

  1. Stop engine, allow to cool, relieve pressure, remove filler cap.
  2. Open drain valves or remove drain plugs; drain coolant.
  3. Flush the cooling system with clean water.
  4. Fill with clean water; run until 49 to 66 C; drain.
  5. Repeat flush steps until water drains clean.
  6. Fill with Extended Life Coolant; do not install filler cap.
  7. Run engine to purge air; check coolant level.
  8. Inspect filler cap gaskets; install cap; inspect for leaks.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What size generator is the Caterpillar 3508?

The Caterpillar 3508 is rated 620 kW standby.

Which engine powers the Caterpillar 3508?

The Caterpillar 3508 is powered by the Caterpillar 3508B engine.

What fuel does the Caterpillar 3508 use?

The Caterpillar 3508 runs on diesel.

What's the oil capacity on a Caterpillar 3508?

The Caterpillar 3508B engine in the Caterpillar 3508 has an oil capacity of 397.0 liters.

How much coolant does the Caterpillar 3508 hold?

The Caterpillar 3508 cooling system holds 285 liters (75.3 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the prime power rating of the Caterpillar 3508?

The Caterpillar 3508 is rated 485 kW prime (641 kVA), against 620 kW standby.

What is the dry weight of the Caterpillar 3508?

The Caterpillar 3508 has a dry weight of 10136 kg (22346 lb).

What voltage does the Caterpillar 3508 produce?

The Caterpillar 3508 is offered in 600 V, 3 phase-phase.

What alternator does the Caterpillar 3508 use?

The Caterpillar 3508 uses a SR4 alternator.

What oil filter does the Caterpillar 3508 use?

The Caterpillar 3508 uses oil filter part number 1R0716.

Which fuel filter part number does the Caterpillar 3508 take?

The Caterpillar 3508 uses fuel filter part number 1R0755.

Which air filter part number does the Caterpillar 3508 take?

The Caterpillar 3508 uses air filter part number 106-3973.

Parts

68
Part #DescriptionQtySystem
106-3973Air filter inner1Air filter Amazon $39.31 eBay $79.98 eBay $39.31 FridayParts $62.16
10R9951Head Gaskets1Gasket Amazon eBay
113-8432Front sealSeal Amazon eBay $128.48
133-5673Fuel/Water Separator1Fuel filter Amazon $47.30 eBay $19.99 eBay $19.99 KuduParts $19.00 FridayParts $20.99
141-7116V-belt1Belt eBay $31.99 FridayParts $22.60
174-6854Hydrosolv 100 liquid cleaner, 19 L (5 US gallon)1Fluid Amazon eBay
1744947Aftercooler and Lines Gaskets1Gasket Amazon eBay
175-7546Oil Filter Cutter1Oil filter Amazon eBay
1R-0716Engine Oil1Oil filter Amazon $52.99 eBay $44.90 eBay $44.90 KuduParts $80.00 FridayParts $81.99
1R-0749Fuel Secondary - ADV1Fuel filter Amazon $90.99 Amazon $19.99 eBay $135.88 eBay $135.88 KuduParts $17.00 FridayParts $47.50
1R-0755High Efficiency Fuel Filter1Filter Amazon $20.99 eBay $34.99 eBay $96.90 KuduParts $54.00 FridayParts $71.99
1R-1808Engine Oil - ADV1Oil filter Amazon $70.99 eBay $141.00 eBay $59.99 KuduParts $80.00 FridayParts $81.99
1R0716Filter oilOil filter Amazon $52.99 eBay $44.90 eBay $44.90 KuduParts $80.00 FridayParts $81.99
1R0719Filter oilOil filter eBay $20.00 FridayParts $31.32 KuduParts $58.00
1R0726Filter oilOil filter eBay $39.99 KuduParts $17.00 FridayParts $19.48
1R0741Filter hydraulicHydraulic filter eBay $22.00
1R0750Filter fuelFuel filter Amazon $16.99 eBay $33.80 eBay $33.80 KuduParts $17.00 FridayParts $29.50
1R0755Filter fuelFuel filter Amazon $20.99 eBay $34.99 eBay $96.90 KuduParts $54.00 FridayParts $71.99
1R0756Filter fuelFuel filter Amazon $28.31 eBay $18.99 eBay $18.99 KuduParts $33.00 FridayParts $34.98
1U-5490Hydrosolv 4165 liquid cleaner, 19 L (5 US gallon)1Fluid Amazon eBay
1U-5492Hydrosolv 100 Liquid Cleaner, 19 L (5 US gal)Fluid eBay
1U-5718Vacuum Pump1Pump Amazon eBay $87.99
1U-8804Hydrosolv 100 Liquid Cleaner, 4 L (1 US gal)Fluid eBay
1U-8812Hydrosolv 4165 Liquid Cleaner, 4 L (1 US gal)Fluid eBay
200-4139axial seal filter(axial seal)Filter Amazon eBay $40.00
212-8176Water pumpPump eBay $629.99
222-5152Water pump repair kitPump eBay $239.99
225-6404radial seal filter(radial seal)Filter Amazon eBay
2322507Manifold Gaskets1Gasket Amazon eBay
2322521Turbocharger Gaskets1Gasket Amazon eBay
2322522Reman Injectors1Injector Amazon eBay
2342795Injector Seals/Gaskets1Gasket Amazon eBay
248-5513ThermostatThermostat Amazon eBay $39.95 eBay $43.00 FridayParts $30.31 SinoCMP $59.00
2W9727Water pump impellerImpeller eBay
3412CEngineEngine Amazon eBay $74.99 FridayParts $18.21 KuduParts $114.00
3508BEnginexEngine Amazon eBay $95.99 FridayParts $18.50 KuduParts $259.00
3S3875Filter fuelFuel filter eBay $49.99
4W3864Water pump sealSeal eBay $9.27
5N-5561Silicone LubricantFluid Amazon eBay
8N6309Air filter outerAir filter eBay $89.68 KuduParts $185.00 FridayParts $290.20
8T-5571Hydrosolv 100 - 208 L (55 US gallon)Fluid eBay
8T-7570Hydrosolv 4165 - 208 L (55 US gallon)Fluid eBay
9G8010SwitchSensor eBay $39.00 FridayParts $16.90
9S-8140Pressurizing PumpPump Amazon eBay
AR86745FUEL FILTER1Fuel filter Amazon $21.99 eBay $42.15 KuduParts $16.00
ESD5526Speed ControllerSpeed controller Amazon eBay
M-4660684Gasket Set - Central & Lower - 3508Gasket set Amazon eBay
R134aAir conditioner50Air filter Amazon Amazon eBay $585.30 eBay FridayParts $25.50
RE508202FUEL FILTER1Fuel filter Amazon $41.99 eBay $19.49 FridayParts $31.02 KuduParts $60.00
138-8440Component cleanerService part / kit Amazon eBay
1440725Connecting rodService part / kit Amazon eBay $630.00
169-8373Fluid Sampling Bottle1Service part / kit Amazon eBay $29.99
1743191Reman Cylinder Heads1Service part / kit Amazon eBay
1U-8760Chain Wrench1Service part / kit Amazon eBay
206-5756PrimeTime Prime Only Configuration KitKitService part / kit Amazon eBay
245-5829Coolant Battery Tester Refractometer1Service part / kit Amazon eBay $98.00
249-0437Oxidation Catalyst Assembly - Round1Service part / kit Amazon eBay
294-7420Refill ampoules for 298-5311 Coolant Nitrite Test Kit1Service part / kit Amazon eBay
298-5311Coolant Nitrite Test Kit for SCA1Service part / kit Amazon eBay
3034NAOil Change IntervalService part / kit Amazon
4C-9301Coolant Conditioner Test Kit1Service part / kit Amazon eBay $30.00
5P-3413Pipe Sealant1Service part / kit eBay $12.37
8T-5296Coolant Conditioner Test Kit1Service part / kit Amazon eBay eBay
9S-3263Compound for the shoulder of a new zinc rod1Service part / kit eBay $30.78
9S-4030Thread LockService part / kit eBay
LEDW3153Supersedes LECW7527Service part / kit Amazon eBay
PEHJ0271Cat® Emissions Upgrade Kits for Select 3500 Marine EnginesService part / kit Amazon eBay
PEHJ0287Cat® Performance Upgrade Kits for Select 3508, 3512, and 3516 Marine EnginesService part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
3.81.0
100%191.850.6
Continuous5.01.3
Prime10%39.010.3
Prime20%62.016.38
Prime25%74.019.55
Prime30%87.022.98
Prime40%112.029.59
Prime50%137.036.19
Prime60%160.042.27
Prime70%183.048.34
Prime75%194.051.25
Prime80%206.054.42
Prime90%232.061.29
Prime100%259.068.42

Available documents

Engine spec — 3508+Land+Mechanical+LEHW0058-00+P5 (Caterpillar)Engine spec — 3508B+Land+Electric+-+LEHW0070-00+P2 (Caterpillar)Engine spec — 3508B 746bkW 1000bhp (Caterpillar)Engine spec — 3508B 783bkW 1050bhp (Caterpillar)Engine spec — 3508B 820bkW 1100bhp (Caterpillar)Engine spec — 3508 IND-A 507bkW (Caterpillar)Engine spec — 3508 IND-A 578bkW (Caterpillar)Engine spec — 3508 IND-A 638bkW (Caterpillar)Engine spec — 3508 IND-C 612bkW (Caterpillar)Engine spec — 3508 IND-C 746bkW (Caterpillar)Engine spec — LECH3874-02 (Caterpillar)Engine spec — LECH3874-07 (Caterpillar)Engine spec — LFDH5502-01 HR (Caterpillar)Engine spec — lecw2462-06 (Caterpillar)Engine spec — lehh0266 (Caterpillar)Engine spec — lehh0395 (Caterpillar)Engine spec — lehh5391 (Caterpillar)Engine spec — lehh8099 (Caterpillar)Engine spec — lehm0094 (Caterpillar)Engine spec — lehm0124 (Caterpillar)Engine spec — lehm0297 (Caterpillar)Engine spec — lehm0300 (Caterpillar)Engine spec — lehm9598 (Caterpillar)Engine spec — lehw0187-01 (Caterpillar)Engine spec — lehw0187 02 (Caterpillar)Engine spec — lehw5308 00 (Caterpillar)Engine spec — lfhh5447 (Caterpillar)Engine spec — lfhh5448 (Caterpillar)Engine spec — lfhh6261 (Caterpillar)Engine spec — lphh8099 (Caterpillar)Engine spec — lshh6258 (Caterpillar)Engine spec — lshh6261 (Caterpillar)Spec sheet — LEHW6123-00 (Caterpillar)Spec sheet — epnsum00 (Caterpillar)Spec sheet — lehm0278 (Caterpillar)Spec sheet — lehw6166 (Caterpillar)Spec sheet — lehw6167 (Caterpillar)Spec sheet — lehw7469 (Caterpillar)Spec sheet — lehw9192 (Caterpillar)Spec sheet — lehw9193 (Caterpillar)Reference — Aug+2010+Engine+Selection+Guide (Caterpillar)Reference — Caterpillar-800-kW-CAT-3508-engine-SN-23Z03067-load-test-report (Caterpillar)Reference — Caterpillar-Oil-and-Gas-Ratings-Guide-2021-03 (Caterpillar)Reference — Final+Ratings+Guide LECW2462-15 9.8.11 (Caterpillar)Reference — Industrial rating guide (Caterpillar)Reference — LECW2462-25 1 oil gas (Caterpillar)Reference — LEGH0002 (Caterpillar)Reference — Ratings Guide Port LPCW2462-15 final LR (Caterpillar)Reference — lehr0592 (Caterpillar)Owner's manual — 3508B+Industrial+Engines-Maintenance+Intervals (Caterpillar)Owner's manual — SEBU7148-09 M (Caterpillar)Parts manual — Caterpillar Engines (Caterpillar)Parts manual — Interstate-McBee-Caterpillar-Custom-Gasket-Set-Catalog (Caterpillar)Parts manual — KMP-Brand®Parts-Guide-Suitable-for-Caterpillar®By-Product (Caterpillar)Parts manual — PEHJ0254 Reman Overhaul Kit8 (Caterpillar)Parts manual — lehw6165 (Caterpillar)Service manual — OT906706 RC (Ohio Department of Administrative Services (DAS), General Services Division, Office of State Purchasing)Service manual — SEBU7147-05 M (Caterpillar)

This page was generated from the 58 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Air filter 106-3973$39.31
Fuel filter 1R0755$20.99
Oil filter 1R0716$44.90
Belt 141-7116$31.99
Battery 245-5829$98.00
Hydraulic filter 1R0741$22.00
6 priced items$257.19