Cummins/Onan 6BTA5.9 Engine

The Cummins/Onan 6BTA5.9 is a 5.9 L 6-cylinder engine. It powers generator sets from Cummins/Onan, including the DGDK. It holds 16 L (4.2 gal) of oil and 31.5 L (8.3 gal) of coolant.

Also known as: Cummins 6BTA5.9

Part of the Cummins/Onan 6BTA5.9 engine family — 11 variants share parts & fitment.

5.9 L
Displacement
6
Cylinders
16.0 L
Oil capacity

Engine specifications

Oil capacity16.0 L
Coolant capacity31.5 L
Displacement5.9 L
Cylinders6

Common problems

15
  • Over Current 1471
  • Low Coolant Level 197
    Cause: Engine coolant level has fallen below the warning trip point.
    Fix: If generator is powering critical loads and cannot be shut down, wait until next shutdown period, then follow code 235 procedure. If engine can be stopped, follow code 235 procedure.
  • Weak Battery 1442
    Cause: During cranking, the battery voltage is at or below the weak battery warning trip point for a time greater than or equal to the weak battery set time.
    Fix: See code 441 for corrective action.
  • Under Frequency 1448
  • Too Long In Idle (10 min.) 2342
    Cause: Genset has been in Idle mode too long (10 minutes maximum).
  • Status Indicators Fault Code Table
  • Speed/Hz Match 1469
  • Speed Signal Lost 121
  • Shutdown After Battle Short 1123
    Cause: Moving the customer installed Battle Short switch to OFF with an active but overridden shutdown fault or a shutdown fault that was overridden at any time.
  • Short Circuit 1445
  • S1 CB Not Open 2397
  • S1 CB Not Close 2396
  • Reverse Power 1459
  • Remote E-Stop 1434
    Cause: Remote Emergency Stop.
    Fix: See code 1433 to reset.
  • Rated/Idle Trans 1122

Compiled from service & troubleshooting documentation across every generator set that uses the Cummins/Onan 6BTA5.9.

Service intervals

29
ItemActionHoursMonthsNotes
Coolant HeaterCheck50 hrVerify hot coolant is being discharged from the outlet hose.
Coolant LevelCheck8 hr
Coolant Level (Recovery Tank)Check8 hrTable 5-1
Exhaust Condensate TrapDrain8 hrTable 5-1
Fuel LevelCheck8 hrTable 5-1
Fuel Tanks (water and sediment)Drain8 hrDrain 1 cup or more of fuel to remove water and sediment.
General Genset InspectionInspect8 hrTable 5-1; also indicated for weekly/50 hours (X1, X2)
Inspect GensetCheck8 hrCheck for oil, fuel, cooling and exhaust system leaks. Check exhaust system audibly and visually with set running and repair any leaks immediately.
Oil LevelCheck8 hrTable 5-1
Water and Sediment from Fuel TankDrain8 hrTable 5-1; drain 1 cup or more of fuel to remove water and sediment
Air CleanerClean50 hrTable 5-1; X3 perform more often in dusty conditions
Battery Charging SystemCheck50 hrTable 5-1
Charge Air PipingCheck50 hrTable 5-1
Crankcase OilDrain50 hrFirst service — Break-in: drain and replace the crankcase oil after the first 50 hours of operation on new generator sets.
Starting BatteriesCheck50 hrTable 5-1
Battery Electrolyte LevelCheck200 hrCheck at least every 200 hours of operation; disregard for maintenance-free battery
Air Cleaner ElementChange500 hr6 moTable 5-1; replace yearly or sooner if service indicator button pops up
Anti-freeze and DCA ConcentrationCheck250 hr6 moTable 5-1
Coolant FilterChange500 hr6 moTable 5-1
Cooling SystemClean500 hr6 moTable 5-1
Crankcase BreatherClean500 hr6 moTable 5-1
Crankcase Oil and FilterChange250 hr12 moTable 5-1 X6: if genset is used for standby applications, change oil every 12 months or 250 hours, whichever comes first
Drive Belt TensionCheck250 hr6 moVisually check belt for evidence of wear or slippage. Replace if hard or brittle. Refer to engine operation and maintenance manual.
Fuel Filter(s)Drain250 hr6 moTable 5-1
Fuel FiltersChange250 hr6 moTable 5-1
Governor AdjustmentCheck250 hr3 mo
Radiator Hoses for Wear & CracksCheck250 hr6 moTable 5-1
Valve LashAdjust1000 hrTable 5-1: after 1000 hours; contact an authorized service center for service
Generator Set ExerciseTest1 moExercise the generator set at least once a month for a minimum of 30 minutes, under not less than 30 percent of the nameplate rating

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceClearance around generator set for maintenance and service access1meter (3 feet)
ClearanceExhaust pipe clearance from combustible wall or partition12inches (305 mm)minimum
ClearanceFloat switch lift below C-clip stop1/8inch (3 mm)
ClearanceFuel line clearance from electrical wiring1/2inch (12.7 mm)minimum
ClearanceFuel line clearance from hot exhaust parts2inch (51 mm)minimum
ClearanceVibration isolator base elevation (max difference between isolator bases)0.25inch (6 mm)
ClearanceVibration isolator top plate to base clearance0.25inch (6 mm)nominal, minimum
OtherBattery electrolyte corrected specific gravity (fully charged)1.260electrolyte temperature corrected
OtherBattery electrolyte specific gravity (fully charged)1.260specific gravitycorrected to 80 F (27 C)
OtherBattery electrolyte specific gravity charge threshold1.215specific gravitycharge battery if reading is below this value
OtherBattery recharge threshold specific gravity1.215
OtherBattery specific gravity temperature correctionfour gravity points (0.004) for every ten degrees above 80 F (27 C)
OtherCool-down at idle0−30min
OtherCustomer output relay contacts rating (TB1 outputs 1-4)2amps at 30 VDCnormally open contacts
OtherCycle crank crank and rest time7 to 20seconds
OtherCycle crank number of cycles3, 4, or 5
OtherDefault start cycles3cycles15 seconds of cranking and 15 seconds of rest
OtherFrequency Adjust range5percent of nominal frequencye.g. 60.0 Hz adjustable 57.0 to 63.0 Hz
OtherFrequency adjustment range±5%%genset running
OtherFuse A31-F1 (control B+)5AmpEngine Interface board
OtherFuse A31-F3 (auxiliary B+)5AmpEngine Interface board; panel lights, run and start relays
OtherFuse A38-F1 (Network B+)10AmpGovernor Output Module
OtherFuse A38-F2 (Switched B+)10AmpGovernor Output Module
OtherFuse A38-F3 (Governor B+)10AmpGovernor Output Module
OtherFuse TB-Bat F1 (Customer B+)20AmpEngine Harness Assembly
OtherGOV RAMP adjustment range0 through 10seconds
OtherLow oil pressure / high engine temperature fault time delayabout 10secondsfollowing starter disconnect and inhibited during cranking
OtherMounting bolts used to secure vibration isolators to base5/8 inch or 16 mmanchored mounting bolts
OtherOptional control relay (K11, K12, K13) contacts rating10amps at 600 VAC
OtherOvercrank limit (Sentinel)60seconds
OtherOvercrank option limit (Detector)75seconds
OtherREG VHZ adjustment range1 through 50 (normal range 7 through 21)
OtherRated To Idle delay0−10secBeginning Version 2.303; default = 0
OtherSetup/calibration menu access code574
OtherSpecific gravity correction factor0.004gravity pointsper 10 degrees electrolyte temperature above 80 F (27 C)
OtherStandard cycle cranking (Detector)three 15-second cranking cycles with two 15-second rest periods
OtherStart delay adjustment range0 to 300secondsremote starting in Auto mode
OtherStop delay adjustment range0 to 600secondsremote stopping in Auto mode
OtherTime Delay To Start0−300secdefault = 0
OtherTime Delay To Stop (Stop Delay)0−600secdefault = 0
OtherVoltage adjustment range±5%%genset running
OtherWarm-up at idle time delay0−300secmanual mode
PressureEngine Oil Pressure (Normal)276-483kPanormal operating
PressureEngine Oil Pressure (Normal)40-70psinormal operating
PressureEngine oil pressure (normal)30 to 65psi (207 to 449 kPa)at normal operating temperature
PressureEngine oil pressure range (low oil pressure troubleshooting)25 to 65psi (172 to 449 kPa)
PressureFuel shutoff valve rating (TB1-8 and TB1-5)not more than 0.5amps120 or 240 VAC
PressureIdle Oil Pressure10-30psiidle
PressureIdle Oil Pressure69-207kPaidle
PressureIdle Oil Pressure Shutdown Limit55kPaidle
PressureIdle Oil Pressure Shutdown Limit8psiidle
PressureIdle Oil Pressure Warning Limit12psiidle
PressureIdle Oil Pressure Warning Limit83kPaidle
PressureIdle oil pressure10 - 30psi (69 - 207 kPa)idle
PressureIdle oil pressure (normal)10-30psi (69-207 kPa)Engine model 6C, idle
PressureLow oil pressure shutdown limit14psi (97 kPa)
PressureMaximum allowable exhaust back pressure41in. H2O
PressureMaximum fuel inlet restriction4in. Hg. (13.5 kPa)
PressureMaximum fuel return restriction20in. Hg. (67.6 kPa)
PressureMaximum radiator cleaning air/water pressure242kPacleaning radiator fins

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantRefer to the Cummins engine Operation and Maintenance Manual for coolant recommendations/specifications25.0 LCapacity with standard radiator 6.5 Gal (25 L) DGDA/DGDB; 8.3 Gal (31.5 L) DGDK; heavy duty diesel engines require a balanced coolant mixture of water, antifreeze and coolant additives
Coolant50/50 mix of water and antifreezeBalanced coolant mixture of water, antifreeze and coolant additivesDrain and replace the mixture every 6 months or after 500 hours of operation. Do not add cold coolant to a hot engine; allow engine to cool below 120 F (50 C) before adding coolant.
Engine oilRefer to Cummins engine Operation and Maintenance Manual for lubricating oil recommendations/specifications16.0 LOil capacity with filters 17 Qts (16 L); gensets are shipped with oil added
FuelASTM No. 2 diesel fuelCummins engines normally use ASTM No. 2 diesel fuel; will operate on alternate diesel fuels within specifications in Cummins engine Operation and Maintenance Manual.
FueldieselDo not use zinc coated or copper fuel lines with diesel fuel.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

80
CodeNameMeaningSeverityAction
101IDLE MODEIndicates that the engine is operating in idle mode. Grounding the engine idle input inhibits generator build-up and governs the engine at 800 RPM.WarningGrounding the engine idle input inhibits generator build-up and governs at 800 RPM; removing ground returns the genset to normal speed and voltage.
102EMERGENCY STOPIndicates local or remote Emergency Stop.ShutdownPull the button out; move the Run/Off/Auto switch to Off; press the Reset switch; select Run or Auto as required. Can only be reset at the PCC front panel.
121SPEED SIGNAL LOSTMag pickup speed indication is not being sensed.ShutdownRestart and check RPM on digital display; inspect MPU wires/connector pins; check for 3.5 to 15 VAC at MPU while cranking.
135OIL PRESSURE SENSOR HEngine oil pressure sender signal is shorted high.WarningCheck sender/connectors/wires; verify fault simulation not enabled; check 0.5 to 4.5 VDC at P7-13 (OP OUT) and P7-17 (OP COM).
141OIL PRESSURE SENSOR LEngine oil pressure sender signal is shorted low.WarningCheck sender/connectors/wires; check for shorts/open circuits at P7-13, 17, 21.
143PRE-LOW OIL PRESEngine oil pressure dropped to an unacceptable level.WarningCheck oil level, lines and filters; replenish if low; if powering critical loads wait until next shutdown period and follow code 415.
144COOL SENSOR HIGHEngine coolant temperature signal is shorted high.WarningCheck sender/connectors/wires; check resistance between P7-30 (IH20) and P7-34 (IH20 COM).
145COOL SENSOR LOWEngine coolant temperature signal is shorted low.WarningCheck sender/connectors/wires; check for shorts at P7-30 and P7-34.
146PRE-HIGH COOL TMPEngine has begun to overheat (coolant temperature risen to an unacceptable level).WarningReduce load; check air inlets/outlets and remove obstructions to airflow; if engine can be stopped follow code 151.
151HIGH COOLANT TEMPEngine has overheated (coolant temperature above the shutdown trip point).ShutdownAllow engine to cool; check coolant level; check airflow obstructions; check fan belt; check blower fan/remote radiator pumps; reset control and restart.
197LOW COOLANT LEVELEngine coolant level has fallen below the warning trip point.WarningAllow engine to cool; check coolant level and replenish; look for leaks; reset control and restart.
200LOW OIL PRESSUREIndicates engine oil pressure has dropped to an unacceptable level.WarningIf generator is powering critical loads and cannot be shut down, wait until next shutdown period and then follow the 201-SHUTDOWN procedure. Access the Oil Pressure menu prior to clearing the fault.
201LOW OIL PRESSUREIndicates engine oil pressure has dropped below the shutdown trip point.ShutdownCheck oil level, lines and filters. If oil system is OK but oil level is low, replenish. Reset control and restart. Oil pressure limits are listed in Table 4-3.
204OIL PRESS SENDERIndicates that the control has sensed that the engine oil pressure sender is out of its working range.WarningCheck that the engine oil pressure sender is properly connected.
210LOW COOLANT TEMPWarning occurs when engine coolant temperature is 70°F (21°C) or lower, indicating the engine coolant heater is not operating or is not circulating coolant.WarningCheck coolant heater power supply, fuse or disconnected heater cord; check for low coolant level and replenish; check for an open heater element by checking current draw of heater.
211HIGH COOLANT TEMPIndicates the engine coolant temperature is getting close to the recommended maximum temperature limit: 215°F (102°C) standby or 207°F (97°C) prime.WarningReduce load if possible; check air inlets and outlets and remove any obstructions to airflow; if engine can be stopped, follow the 212-SHUTDOWN procedure.
212OIL TEMP SENSOR HEngine oil temperature signal is shorted high.WarningCheck sender/connectors/wires; check resistance between P7-22 (OIL TEMP) and P7-26 (OIL TEMP COM).
213OIL TEMP SENSOR LEngine oil temperature signal is shorted low.WarningCheck sender/connectors/wires; check shorts and resistance between P7-22 and P7-26.
214LOW COOLANT LVLIndicates engine coolant level has fallen below the trip point.WarningAllow engine to cool; check coolant level in both radiator and coolant recovery bottle and replenish; look for coolant leakage points; reset control and restart.
215LOW COOLANT LVLIndicates engine coolant level has fallen below the trip point. LOW COOLANT LVL Shutdown will not occur if genset is in Idle mode (low coolant warning only).ShutdownAllow engine to cool; check coolant level in both radiator and coolant recovery bottle and replenish; if radiator level is low and bottle level correct, check coolant bottle hose or radiator cap; reset control and restart.
220MAG PICKUPIndicates mag pickup speed indication is not being sensed or does not match generator set output frequency.ShutdownRestart and check RPM on the digital display. Check MPU sender, wiring and adjustment.
221FAIL TO CRANKIndicates possible fault with control or starting system.ShutdownCheck fuse F3 on the Engine Interface board; check for poor battery cable connections; recharge or replace a discharged or defective battery.
222OVERCRANKIndicates possible fuel system problem.ShutdownCheck for empty fuel tank, fuel leaks, or plugged fuel lines; check for dirty fuel filter and replace if necessary; check for dirty or plugged air filter and replace if necessary; reset the control and restart.
223OVERSPEEDIndicates engine has exceeded normal operating speed (115% ±1% of nominal).ShutdownInspect the mechanical fuel linkage and repair or replace; check the EFC for binding or damage; monitor the PCC duty cycle display and replace A32 or A38 as indicated.
230LOW DC VOLTAGEIndicates battery voltage is below 10 VDC.WarningCheck for discharged or defective battery; check the battery charger fuse; recharge or replace the battery; clean and tighten battery cable connections; check engine DC alternator; check battery charge voltage float level.
231HIGH DC VOLTAGEIndicates battery voltage exceeds 32 VDC.WarningCheck voltage float level on battery charger if applicable (lower float level); check engine DC alternator and replace if normal battery charging voltage is not obtained.
232WEAK BATTERYIndicates battery voltage drops below 60% of nominal for two seconds, during starting.WarningDischarged or defective battery. See Warning message 230, LOW DC VOLTAGE.
234OVERSPEEDEngine has exceeded normal operating speed.ShutdownClear fault and restart genset; check fault threshold; monitor RPM; check electronic governor actuator.
235LOW COOLANT LEVELEngine coolant level has fallen below the shutdown trip point.ShutdownCheck coolant level and replenish; look for leaks; reset control and restart.
240LOW FUEL-DAYIndicates day tank fuel supply is running low.WarningCheck fuel supply and replenish as required.
241LOW FUELIndicates fuel supply is running low.WarningCheck fuel supply and replenish as required.
250EEPROM ERRORIndicates PCC memory error. Data corruption of critical operating parameters.ShutdownPerform the Initial Start Setup procedure and save; if the same EEPROM ERROR occurs, replace the digital board (A32).
251EEPROM ERRORIndicates PCC memory error. Data corruption of noncritical operating parameters.WarningPerform the adjustment procedures and save; if the same EEPROM ERROR occurs, perform the calibration procedures; if it still occurs, replace the digital board (A32).
252EEPROM ERRORIndicates PCC memory error. Data corruption of noncritical operating parameters.WarningVerify the values or choices selected and repeat the save operation; if the same EEPROM ERROR occurs, replace the digital board (A32).
260CUSTOMER FAULT 1Customer defined input closed to ground; the nature of the fault is an optional customer selection which can be programmed to initiate a shutdown or a warning. Default message is editable.WarningIsolate the source of the false signal; disconnect the signal lead near the control and reset; if the message drops out there is a short to ground in the external wiring; if it remains replace A34. Customer fault messages are editable.
261GROUND FAULTCustomer defined input closed to ground; the nature of the fault is an optional customer selection. Default message is editable.WarningIsolate the source of the false signal; check the corresponding customer interface board LED; disconnect the signal lead and reset the control; replace A34 or A32 as indicated.
262RUPTURE BASIN / DAY TANKCustomer defined input closed to ground; the nature of the fault is an optional customer selection. Default message is editable.WarningIsolate the source of the false signal; check the corresponding customer interface board LED; disconnect the signal lead and reset the control; replace A34 or A32 as indicated.
263HIGH GEN TEMPCustomer defined input closed to ground; the nature of the fault is an optional customer selection. Default message is editable.WarningIsolate the source of the false signal; check the corresponding customer interface board LED; disconnect the signal lead and reset the control; replace A34 or A32 as indicated.
301HIGH AC VOLTAGEIndicates that one or more of the phase voltages has exceeded 130% of nominal, or has exceeded 110% of nominal for 10 seconds.ShutdownSet the display to GEN VOLTS L-N and observe; determine if the output voltage the control sees is low or high; isolate to the PCC, alternator, PT/CT module (A36), customer interface board (A34), analog board (A33) or digital board (A32).
303LOW AC VOLTAGEIndicates that one or more of the phase voltages has dropped below 85% of nominal for 10 seconds.ShutdownCheck and repair the PMG or field wiring; check rotating rectifier diodes; check the load and correct any overload; check connectors J8 and J9 on A36, J3 and J5 on A34, and J7 on A37; isolate to A33, A32, A37 or A31.
313UNDER FREQUENCYIndicates that engine speed has dropped below 90% of nominal for 10 seconds. Five seconds before shutdown, a Load Dump signal is initiated.ShutdownCheck Initial Setup (set size); check load and correct any overload; check fuel supply, intake air supply and load; refer to the fault-finding table.
320OVERCURRENTIndicates that generator output current has exceeded 110% of rated for 60 seconds.WarningCheck load and load lead connections.
321OVERCURRENTIndicates that generator output current has exceeded 110% of rated, and that a PCC time/current calculation has initiated an overcurrent shutdown.ShutdownCheck load and load lead connections.
322SHORT CIRCUITIndicates that generator output current has exceeded 175% of rated.ShutdownCheck load and load lead connections.
330OVERLOADIndicates that three-phase power output exceeds 105% of standby (or 115% of prime) rating. After five seconds, the Load Dump output is activated. After 60 seconds, the OVERLOAD warning is activated.WarningCheck load and load lead connections.
335REVERSE POWERIndicates improper CT or PT phasing (non-parallel units only).ShutdownCheck CT / PT wiring. Refer to CT Installation in Section 5.
359FAIL TO STARTEngine cranks but fails to start (possible fuel system problem).ShutdownCheck for empty fuel tank, fuel leaks, or plugged fuel lines; replace dirty fuel filter; replace dirty air filter; reset control and restart.
415LOW OIL PRESSUREEngine oil pressure has dropped below the shutdown trip point.ShutdownCheck oil level, lines and filters; replenish if low; reset control and restart.
421OIL TEMPEngine has begun to overheat (oil temperature above unacceptable level) (Optional).WarningReduce load; check air inlets/outlets; if engine can be stopped follow code 151 and check engine oil level.
441LOW BAT VOLTAGEBattery voltage supply to the control approaching a low level.WarningCheck battery charger fuse; recharge or replace battery; clean and tighten cable connections; check engine DC alternator.
442HIGH BAT VOLTAGEBattery voltage supply approaching a high level at which control damage can occur.WarningCheck float level on battery charger; check battery wiring/calibration.
1122Rated/Idle TransRated/Idle transitionInfo
1123SHUTDOWN AFTER BSA shutdown fault occurred while Battle Short was enabled and transitioned from enabled to disabled.ShutdownReview Fault History and perform corrective action.
1124DELAYED SHUTDOWNA shutdown fault became active while the Delayed Shutdown feature was enabled.WarningReview Fault History and perform corrective action.
1131BATTLE SHORT ACTIVEControl is in Battle Short mode (bypasses several critical fault shutdowns).WarningNone; used for genset operation during emergencies.
1311Customer Input #1Customer input #1 (optional customer selection)Programmable (service tool): enable/disable input (default enable); status, warning or shutdown (default #1 = None); active closed or open (default closed [ground]); change display name up to 19 characters.
1311, 1312, 1317, 1318CUSTOMER INPUT #1 - #4Optional customer-selected fault input is active.Disconnect signal lead from TB1 and reset the control; check external wiring/active input selection.
1312Customer Input #2Customer input #2 (optional customer selection)Programmable (service tool): enable/disable input (default enable); status, warning or shutdown (default #2 = Warning); active closed or open (default closed [ground]); change display name.
1313−1316Network Fault 1 thru 4Network fault 1 through 4
1317Customer Input #3Customer input #3 (optional customer selection)Programmable (service tool): enable/disable input; status, warning or shutdown; active closed or open; change display name.
1318Customer Input #4Customer input #4 (optional customer selection)Programmable (service tool): enable/disable input; status, warning or shutdown; active closed or open; change display name.
1334CRIT SCALER ORIncorrect feature or calibration was entered into control.ShutdownReload correct feature/calibration file.
1335NONCRIT SCALER ORIncorrect feature or calibration was entered into control.WarningReload correct feature/calibration file.
1337No MessageNo messageInfo
1416FAIL TO SHUTDOWNGenset continues to run after receiving shutdown command (Battle Short feature enabled).WarningCheck Battle Short feature setting.
1417POWER DOWN ERRORController cannot power down because of an unknown condition.WarningCheck for possible battery drain.
1433EMERGENCY STOPLocal Emergency Stop.ShutdownPull the button out; move switch to O; press Fault Acknowledge/Reset; select Manual or Auto.
1434REMOTE E-STOPRemote Emergency Stop.ShutdownSee code 1433 to reset.
1435LOW COOLANT TEMPEngine coolant heater is not operating or not circulating coolant (coolant <=70 F [21 C]).WarningCheck coolant heater power/fuse/cord; check coolant level; check heater element (10 to 60 ohms); check sensor.
1438FAIL TO CRANKEngine failed to crank after the PCC received a start signal.ShutdownTest for B+ at the starter; check fuse F3 (2 Amps); check K4 start pilot relay and starter circuitry; refer to code 121.
1442WEAK BATTERYDuring cranking battery voltage at or below weak battery trip point.WarningRecharge or replace battery; check electrolyte level and connections; check harness.
1443BATTERY FAILEDDead battery - engine will not start.ShutdownSee code 1438 instructions.
1444KW OVERLOADGenerator output power exceeded 105% of genset rating (3 sec at 110% of rated).WarningCheck load and load lead connections; check CTs and CT connections.
1445SHORT CIRCUITGenerator output current exceeded 175% of rated.ShutdownCheck load and load lead connections (fault may not reset for several minutes).
1446HIGH AC VOLTAGEPhase voltage exceeded 130% of nominal, or 110% of nominal for 10 seconds.ShutdownCheck fault simulation; clear fault and restart; refer to Generator/Base Board Isolation Procedure.
1447LOW AC VOLTAGEPhase voltage dropped below 85% of nominal for 10 seconds.ShutdownCheck load; reconnect per reconnection diagram; check PMG/field wiring; check P8-21/P8-22 shunt connections.
1448UNDER FREQUENCYEngine speed dropped below 90% of nominal for 10 seconds.ShutdownCheck fuel supply, intake air supply and load; check P8 connections.
1449OVER FREQUENCYFrequency is 10% above base frequency for 20 seconds.WarningCheck fuel or air delivery problem; repair P7/P8 connections.
1452GEN CB NOT CLOSEGenset circuit breaker (S2) failed to close when PTC enabled.WarningRefer to Section 5.
1453GEN CB NOT OPENGenset circuit breaker (S2) failed to open when PTC enabled.WarningRefer to Section 5.

Showing the first 80 of 107 codes.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjusting Default Settings (Controller Configuration Menu) adjustment
  1. Make sure Main Menu 1 is displayed and simultaneously press the Home Menu and Previous Main Menu buttons.
  2. Press the buttons next to the and symbols to navigate between the three submenus.
  3. Press the button next to the symbol until the + and − symbols are displayed.
  4. Press the button next to the + or − symbol to select the desired option.
  5. Press the symbol to save the changes.
Adjusting Values/Parameters (Adjust Menu) adjustment

⚠ If the Home button or Previous Main Menu button is pressed before pressing the save symbol, the changes are not saved.

⚠ Long periods of engine idling can eventually affect engine performance and may void engine warranty.

  1. Press the button next to the symbol in the display until the + and − symbols are displayed.
  2. If necessary, press the button next to the or symbols to move to the numeric character you wish to change.
  3. Press the button next to the + symbol to increase the value; press the button next to the − symbol to decrease the value.
  4. After adjusting, press the symbol to save; make sure the cursor is on the last numeric character before pressing.
Adjusting Values/Parameters (PowerCommand 2100 Control) adjustment
  1. Press the button next to the down arrow symbol until the + and - symbols are displayed.
  2. Press the button next to the arrow symbols to move to the numeric character to be changed.
  3. Press the button next to + to increase the value or select a parameter; press - to decrease.
  4. Press the save symbol to save the changes (make sure the cursor is on the last numeric character).
  5. If the Home button or Previous Main Menu button is pressed before the save symbol, the changes are not saved.
Controller Configuration (PowerCommand 2100 Control) adjustment
  1. Make sure Main Menu 1 is displayed.
  2. Simultaneously press the Home Menu and Previous Main Menu buttons to view the first Controller Configuration menu.
  3. Press the buttons next to the up and down symbols to navigate between menus.
  4. Press the button next to the + or - symbol to select the desired option.
  5. Press the save symbol to save changes; pressing Home or Previous Main Menu before the save symbol leaves changes unsaved.
Day Tank Controller Conversion 240 VAC to 120 VAC adjustment
  1. Remove the two jumpers between terminals TB1-6 and TB1-7 and connect one between TB1-5 and TB1-6 and the other between TB1-7 and TB1-8.
  2. Move selector switch S103 on the control PCB to the up position for 120V.
  3. On the control transformer, remove the two jumpers between terminals H2 and H3 and connect one between H1 and H3 and the other between H2 and H4.
Torque Tester / Current Transformer Installation Check adjustment
  1. Verify the dot on the CT faces toward the generator.
  2. Verify CT21 is on U load leads, CT22 on V load leads, CT23 on W load leads.
  3. Verify the correct CT secondary terminal (pin 2 high voltage / pin 3 low voltage) is used.
  4. Check CT/PT wiring if a 335 Reverse Power shutdown occurs.
Generator/Base Board Isolation Procedure diagnostic

⚠ This test involves unregulated excitation; disconnect all loads.

⚠ HAZARDOUS VOLTAGE.

Tools: Voltmeter, 12 volt battery, Jumpers

  1. Throw line circuit breaker OFF and shut down the set.
  2. Remove control housing side cover; disconnect exciter stator X and XX leads from AC harness.
  3. Prepare to measure output voltage across generator terminals while set runs.
  4. Connect a 12V battery jumper positive (+) to X lead (Field +).
  5. Check polarity again; polarity must be correct.
  6. Start the set and connect battery negative (-) jumper to XX lead.
  7. If rated output voltage or higher and all phases balanced, generator is likely OK.
  8. If unbalanced troubleshoot main stator; if uniformly low troubleshoot exciter and field circuits.
Servicing the PMG - Testing diagnostic

⚠ HAZARDOUS VOLTAGE. Touching uninsulated high voltage parts inside the control and power output boxes can result in severe personal injury or death.

Tools: Wheatstone bridge or digital ohmmeter

  1. Disconnect leads P2, P3 and P4 from the voltage regulator.
  2. Start the engine at the set and let the speed stabilize.
  3. Measure voltage across lead pairs P2-P3, P3-P4 and P4-P2 (at least 150 VAC for 50 Hz, at least 180 VAC for 60 Hz).
  4. If voltages are low or uneven, check all leads and connections before disassembling the PMG.
  5. Stop the set and measure electrical resistance across P2-P3, P3-P4 and P4-P2 (approximately 4.4 ohms each winding).
Testing the Float Switch Assembly diagnostic

Tools: Ohmmeter, Feeler gauge

  1. Remove fuel pump control cover, disconnect wiring jack, unscrew assembly from top of day tank.
  2. Holding assembly vertical, test continuity between each pair of colored leads; all readings zero.
  3. Lift each float to 1/8 inch (3 mm) below the C-clip stop and test continuity; all readings infinity.
  4. Use pipe thread sealant when replacing the assembly.
Testing the Generator Stator and Rotor Windings diagnostic

⚠ Disconnect the starting battery cables (negative [-] first) to make sure the engine will not start while performing these tests.

Tools: Wheatstone bridge or digital ohmmeter (0.001 ohm precision), Megger or insulation resistance meter

  1. Disconnect battery cables (negative first) so the engine will not start.
  2. Measure winding resistance with a Wheatstone bridge or digital ohmmeter and compare to Table 6-1.
  3. Measure winding insulation resistance between leads and laminations; replace if less than 1 megohm.
  4. For the main stator, measure across each pair of stator leads (U1-U2, U5-U6, V1-V2, V5-V6, W1-W2, W5-W6).
Testing the PMG diagnostic

⚠ HAZARDOUS VOLTAGE.

Tools: Voltmeter, Wheatstone bridge or digital ohmmeter

  1. Disconnect PMG leads PMG 2, 3 and 4 from AC harness connectors.
  2. Start engine and let speed stabilize.
  3. Measure voltage across PMG 2&3, PMG 3&4 and PMG 4&2.
  4. Voltage should be at least 150 VAC (50 Hz) or 180 VAC (60 Hz) and equal.
  5. Stop set and measure resistance across each pair; each winding approximately 4.4 ohms.
Testing the Rotating Rectifier Assembly Diodes diagnostic

⚠ Layers of dust can cause diodes to overheat and fail. Brush dust off regularly.

Tools: Ohmmeter

  1. Disconnect the diode pigtails from the terminal posts.
  2. Measure electrical resistance between each diode pigtail and the plate on which the diode is mounted.
  3. Reverse the meter test probes and repeat the tests.
  4. Replace the diode if resistance is high or low in both directions.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
CT1 - U load leads (A phase); CT2 - V load leads (B phase); CT3 - W load leads (C phase)6 lead gensets: generator output leads routed through CTs; 12 lead gensets: load wires routed through CTs12-lead sets have dual secondary CTs (3 pins); 6-lead sets have single secondary CTs (2 pins)
110V - 120V L-NSingle phase, 2-wireJumper locations for single phase, 2-wirePTC Module AC wiring (0300-5382-01, -02)
190, 200, 208, 220, 230, 240, 380, 416, 440, 460, 600 (L-L)3 (three phase)3 or 4 wiresVoltage Configuration submenu; default = 3Ph 208V 4W
190V - 240V L-LThree phaseJumper locations for three phase, 190V-240V L-LUse 0300-5382-01 for 190V-240V L-L, 50/60 Hz
200, 220, 230, 240 (L-L)1 (single phase)3 wiresVoltage Configuration submenu (Governor/Regulator Setup)
200V - 240V L-LSingle phase, 3-wireJumper locations for single phase, 3-wirePTC Module AC wiring
380V - 600V L-LThree phaseJumper locations for three phase, 380V-600V L-LUse 0300-5382-02 for 380V-600V L-L, 50/60 Hz

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Parts cataloged across the Cummins/Onan 6BTA5.9 family

4
Part #DescriptionCategory
3824469fuel pump gear pullerFuel pump
3822509Injection Pump Bore Brush Service ToolInjector
3823276injector bore brushInjector
3377259bosch timing tool (ve)Service part / kit

Parts cataloged across all variants of this engine family — verify the exact part fits your specific variant and serial number before ordering.

Common questions

What is the oil capacity of the Cummins/Onan 6BTA5.9?

The Cummins/Onan 6BTA5.9 engine has an oil capacity of 16.0 liters.

What is the displacement of the Cummins/Onan 6BTA5.9?

The Cummins/Onan 6BTA5.9 has a displacement of 5.9 liters with 6 cylinders.

Which generators use the Cummins/Onan 6BTA5.9 engine?

The Cummins/Onan 6BTA5.9 powers 1 generator set(s), including Cummins/Onan DGDK.

What is a common problem with the Cummins/Onan 6BTA5.9 engine?

A commonly reported issue on generators using the Cummins/Onan 6BTA5.9 is: Over Current.