| Clearance | Angular alignment maximum T.I.R. | 0.001 | inch per inch of radius (center of shaft to indicator axis) | measuring deflection to bolt heads |
| Clearance | Exhaust pipe clearance from combustible wall or partition | 12 | inches (305 mm) | minimum |
| Clearance | Exhaust pipe clearance to combustible wall or partition | 305 | mm | |
| Clearance | Exhaust pipe clearance to combustible wall/partition | 12 | inches (305 mm) | |
| Clearance | Exhaust pipes to combustible wall or partition | 305 mm (12 inches) | mm | |
| Clearance | Float switch assembly float lift clearance below C-clip stop | 1/8 | inch (3 mm) | use a feeler gauge |
| Clearance | Fuel line clearance from electrical wiring | 1/2 | inch (12.7 mm) | |
| Clearance | Fuel line clearance from hot exhaust parts | 2 | inch (51 mm) | |
| Clearance | Fuel lines - minimum clearance from electrical wiring | 12.7 | mm | |
| Clearance | Fuel lines - minimum clearance from hot exhaust parts | 51 | mm | |
| Clearance | Fuel lines to electrical wiring | 12.7 mm (1/2 inch) minimum | mm | |
| Clearance | Fuel lines to hot exhaust parts | 51 mm (2 inches) minimum | mm | |
| Clearance | Generator mount pre-load steel spacer thickness | 1 3/4 | inch | two spacers under both stator foot brackets |
| Clearance | Generator-to-engine angular alignment (T.I.R.) | .001 in. per inch of radius (center of shaft to indicator axis), maximum | in | 750 kW gensets and larger |
| Clearance | MPU installation gap adjustment | back out 1/4 turn after touching gear tooth | turn | |
| Clearance | Minimum clearance of fuel lines from electrical wiring | 12.7 | mm (1/2 inch) | |
| Clearance | Minimum clearance of fuel lines from hot exhaust parts | 51 | mm (2 inch) | |
| Clearance | Service/maintenance access clearance around generator set | 1 | meter | |
| Clearance | Vibration isolator base elevation difference | 0.25 | inch (6 mm) | shimmed or grouted within this of each other |
| Clearance | Vibration isolator clearance | 0.25 | inch (6 mm) | |
| Clearance | Vibration isolator clearance between top plate and base | 6 mm (0.25 inches) or greater | mm | nominal |
| Clearance | Vibration isolator nominal clearance (leveling bolt) | 0.25 | inch (6 mm) | minimum, or greater |
| Gap | Coolant level below radiator cap lower sealing surface | 3/4 inch (18 mm) | inch (mm) | |
| Gap | MPU sensor to flywheel ring gear tooth | back it out one quarter turn | turn | sensor threaded in until it just touches gear tooth |
| Other | AC control wire strip length | 6.0 mm (0.236 in) screw type; 10 mm (0.75 in) push type | mm | |
| Other | AVR Droop setting | 5 | % at full load, 0 PF | |
| Other | AVR voltage regulation (load regulation) | approximately ±0.5 | % RMS | |
| Other | Ambient temperature below which coolant heaters recommended (NFPA 110) | 40 | °F | |
| Other | Amperage PH1 | 0, 615, 615, 614, 613, 613, 0 | A | warm up / start / 15 min / 30 min / 45 min / 1 hour / cool down |
| Other | Amperage PH2 | 0, 618, 618, 617, 618, 617, 0 | A | warm up / start / 15 min / 30 min / 45 min / 1 hour / cool down |
| Other | Amperage PH3 | 0, 612, 612, 611, 611, 611, 0 | A | warm up / start / 15 min / 30 min / 45 min / 1 hour / cool down |
| Other | Angular alignment maximum T.I.R. | .001 inches per inch of radius | in/in | center of shaft to indicator axis |
| Other | Battery CCA (minimum) | 1400 | CCA | Cold Soak @ 0° F (-18° C) |
| Other | Battery charging alternator output | 35 | Amps | |
| Other | Battery electrolyte maximum permissible temperature during charge | 45 °C (113 °F) | °C | during charge |
| Other | Battery electrolyte specific gravity | 1.260 | SG | corrected at 25 °C (77 °F); charge if below 1.215 |
| Other | Battery electrolyte specific gravity, for filling new cells, ambient normally below 32 °C (90 °F) | 1.270 | SG | |
| Other | Battery specific gravity (fully charged) | 1.26 | specific gravity | at 80 F (27 C) |
| Other | Battery specific gravity (high ambient, above 95F/35C) | 1.225 | | recommended to reduce electrolyte loss |
| Other | Battery specific gravity (recharge threshold) | below 1.260 | | |
| Other | Battery specific gravity charge threshold | 1.215 | corrected | charge battery if reading below |
| Other | Battery specific gravity fully charged | 1.260 | corrected | add 0.004 per 10 F above 80 F (27 C) |
| Other | Battery specific gravity, fully charged | approximately 1.260 | specific gravity | at 80 F (27 C) |
| Other | Battery specific gravity, fully charged, corrected | 1.260 | SG | at 25 °C (77 °F) |
| Other | Battery temperature sensor fault trip temperature (fault code 2263) | 55 | °C | 131 °F |
| Other | Battery terminal cleaning solution | 1/4 pound baking soda to 1 quart water | | |
| Other | CAN datalink main trunk maximum length | 40 | meters | no more than 30 devices |
| Other | CAN datalink stub maximum length | 1 | meter | stub from main trunk to each module |
| Other | CAN datalink transmission speed | 250 | KBaud | |
| Other | Charge battery if specific gravity below | 1.215 | specific gravity | |
| Other | Charge battery if specific gravity reading is below | 1.215 | SG | |
| Other | Compression ratio | 17.0:1 | | |
| Other | Cooling system make-up water maximum calcium/magnesium (hardness) | 170 | ppm (as CaCO3) | |
| Other | Cooling system make-up water maximum chloride | 40 | ppm (as Cl) | |
| Other | Cooling system make-up water maximum sulfate | 100 | ppm (as SO4) | |
| Other | Default starting cycles | 3 (15 seconds cranking, 30 seconds rest) | cycles | configurable 1-7 cycles |
| Other | Engine Hours | 371.2, 371.3, 371.5, 371.8, 372, 372.3, 372.4 | h | warm up / start / 15 min / 30 min / 45 min / 1 hour / cool down |
| Other | Exhaust flow at rated load | 2900 | cfm (1370 L/s) | 1500 RPM |
| Other | Exhaust flow at rated load | 3200 | cfm (1510 L/s) | 1800 RPM |
| Other | Exhaust outlet size | 4 | in. NPD | |