Home›Controllers›Mechanical

Mechanical Controller

The Mechanical is a generator-set controller. It is used on generator sets from Caterpillar, Cummins/Onan, Iveco/FPT and Weichai, including the 17 C4.4, C110D6, C135 D6 and C170 D6.

11
Generator sets
4
Brands
5–208 kW
Power range
3
Fuel types

Generator sets using this controller

11

Used across brands: Caterpillar, Cummins/Onan, Iveco/FPT, Weichai

Also fitted to: Cummins/Onan HGJAA (Spec J-K) - 6.5 kW LPG, Cummins/Onan HGJAB (Spec J-L) - 5.5 kW Gasoline.

Troubleshooting

33

Fault codes

CodeMeaningCauseRemedy
12Over VoltageA. Contact Local Dealer or Distributor
13Under VoltageA. Reduce Load
14Over FrequencyA. Contact Local Dealer or Distributor
15Under FrequencyA. Reduce Load
19Governor ActuatorA. Contact Local Dealer or Distributor
2Indicates that the low oil pressure cutoff switch did not open.A. Check Engine Oil Level 1. If the dipstick indicates oil is low, add oil. 2. If oil is above the full mark on dipstick, drain excess oil.
22Governor Actuator OverloadA. Reduce Load
27Voltage SenseA. Contact Local Dealer or Distributor
29High Battery VoltageA. Check Battery
3Service Check
31Over SpeedA. Contact Local Dealer or Distributor
32Low Cranking SpeedA. Check Battery
35Control Card FailureA. Contact Local Dealer or Distributor
36Engine StoppedA. Check Fuel Level
37Invalid Generator Set ConfigurationA. Contact Local Dealer or Distributor
38Over Current (Field Overload)A. Reduce Load
4Indicates that cranking exceeded 30 seconds without engine starting.A. Check Fuel Level 1. If fuel level is low, fill the fuel tank. NOTICE The generator set fuel pickup tube could be higher up in the fuel tank than the vehicle engine pickup. 2. Prime the engine fuel system by positioning the control switch to STOP/PRIME for 30 seconds. B. Check LPG Level Check and fill the LPG container, as necessary. NOTICE On cold days, the LPG container may have to be kept at least half full to provide the rate of vaporization necessary to keep up with the generator set fuel demand. C. Check Spark Plug(s) 1. Secure the spark plug lead(s) on the spark plug(s). 2. Replace the spark plug(s). D. Check Air Filter Element Replace the air filter if dirty. E. Replace Engine Oil Replace engine oil with oil of proper viscosity for the ambient temperature.
41Generator RotorA. Contact Local Dealer or Distributor
42ProcessorA. Contact Local Dealer or Distributor
45Speed SenseA. Contact Local Dealer or Distributor
47IgnitionA. Contact Local Dealer or Distributor
48Generator Field SenseA. Contact Local Dealer or Distributor
52Fuel InjectorA. Contact Local Dealer or Distributor
54MAT SenderA. Contact Local Dealer or Distributor
56MAP SenderA. Contact Local Dealer or Distributor
57Over PrimeA. Check Control Switch
Code 81Exhaust Gas Temperature Sensor OpenContact Local Dealer or Distributor
Code 82Exhaust Gas Temperature Sensor ShortedContact Local Dealer or Distributor

Symptoms & remedies

SymptomCauseRemedy
No AC Power—Generator Set Running, Status Light Flashing RapidlyGenerator set is operating in Engine Run Only (ERO) mode due to a faulty generator (see Section 4.3.5 on page 26)Contact Local Dealer or Distributor
No Power—Generator Set Running, Status Light OnLine circuit breaker is OFF, or tripped due to short circuit or overloadA. Check Line Circuit Breakers 1. Turn on or reset the line circuit breaker on the generator set. 2. Turn on or reset the line circuit breaker on the main distribution panel in the vehicle.
Starter Engages-DisengagesCranking voltage dips below 6 VoltsA. Use Vehicle to Start Generator Set Run the vehicle propulsion engine while trying to start the generator set—the battery charging alternator may be able to maintain starting voltage high enough to start the generator set. B. Check Battery 1. Clean and tighten the positive (+) and negative (–) battery cable connections at the battery and at the generator set. 2. Recharge or replace the battery. Refer to the battery manufacturer's recommendations. C. Change Battery Cables Increase battery cable size or run parallel cables.
Starting Batteries Run DownProblem with batteries, connections, charging system, or parasitic loadsA. Check Battery 1. Clean and tighten the positive (+) and negative (–) battery cable connections at the battery and at the generator set. 2. Recharge or replace the battery. Refer to the battery manufacturer's recommendations. B. Battery Charging System Install or service a battery charging system in the vehicle.
Status Indicator Not WorkingFaulty connections or no battery voltageA. Check Other Control Switch B. Check Battery 1. Clean and tighten the positive (+) and negative (–) battery cable connections at the battery and at the generator set. 2. Recharge or replace the battery. Refer to the battery manufacturer's recommendations.

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.