Home TroubleshootingGenerac iX 2000

Generac iX 2000 Troubleshooting

Generac iX 2000 troubleshooting: 29 fault codes and symptom-cause-remedy entries from the manufacturer's own service documentation.

Generac iX 2000 — full specs, parts & maintenance.

All Generac fault codes →

Troubleshooting

29

Symptoms & remedies

SymptomCauseRemedy
No DC OutputTEST 6 – TEST DC COIL ON STATOR BAD - REPLACE STATOR
Overload Light is OnIS THE LOAD CONNECTED?DISCONNECT THE LOAD, THEN RESTART THE ENGINE AND CHECK THE AC OUTPUT AGAIN YES - GOOD NO - BAD - REPLACE COMPONENT
Engine Will Not Pull StartTEST 7 – TEST RECOIL FUNCTION GOOD TEST 8 – TEST ENGINE FUNCTION BAD - REPLACE SWITCH BAD - REPLACE INVERTER MODULE
Flex Power Feature is Not RespondingTEST 21 – TEST FLEX POWER SWITCH REPLACE CARBURETOR REPLACE FUEL PUMP REPAIR OR REPLACE STATOR REPLACE IGNITION COIL REPLACE LED MODULE
Engine Will Not StartTEST 17 – CHECK CHOKE ASSEMBLY TEST 16 – TEST FUEL SHUTOFF SWITCH TEST 14 – TEST TRIGGER ASSEMBLY TEST 15 – TEST IGNITION COIL TEST 20 – TEST IGNITION WINDING TEST 9 – CHECK SPARK TEST 10 – CHECK SPARK PLUG GOOD - GOOD BAD - REPLACE IGNITION COIL BAD - REPLACE STEPPER MOTOR BAD - REPLACE INVERTER MODULE BAD - REPLACE LED MODULE
Engine Hunts / Erratic Idle or Will Not Come Up to SpeedIS THE UNIT PRODUCING AC POWER? IS THE ENGINE RUNNING ERRATICALLY?BAD – ENGINE MISS APPARENT - REPLACE ENGINE BAD - REPLACE LED MODULE GOOD - REPLENISH OIL BAD
Unit Shuts Down for Low OilTEST 20 – TEST OIL LEVEL SWITCH CHECK OIL LEVEL GOOD
If CONTINUITY is measured across the circuit breakerReplace the DC circuit breaker and re-test
If the meter indicated any reading other than what was specifiedReplace the rectifier
The resistance measured between the all tests points should be as follows: iX 1600 0.2 Ohms, iX 2000 0.3 OhmsReplace the stator
If the recoil did not perform as the observations are stated aboveThe engine could be seized. The recoil could have become detached from the flywheel. The recoil mechanism could be broken and not retracting properly.
If the engine can not turn over freely with the spark plug removedThe engine has suffered some type of internal failure that has seized it and is inhibiting it from running
Clean and regap or replace sparks plug as necessary.Refer back to the Flow Chart.
If fuel does not flowReplace the fuel pump
Compression is poor.Loose cylinder head bolts. Failed cylinder head gasket. Burned valves or valve seats. Insufficient valve clearance. Warped cylinder head. Warped valve stem. Worn or broken piston ring(s). Worn or damaged cylinder bore. Broken connecting rod. Worn valve seats or valves.
Meter reading is outside ± 5 ohms of the correct resistance in Test 14 – Test Ignition Trigger Assembly.Replace trigger assembly.
Incorrect values were measured in Steps 4 and 5 of Test 15 – Test Ignition Coil.Inspect ignition coil connector for bad connection. If the connection is verified good, replace ignition coil. Inspect the ground connection on Pin 2 of the C2 connector going to the ignition coil.
Meter read CONTINUITY when the shutoff valve was in either the open or closed position in Test 16 – Test Fuel Shutoff Switch.Verify mechanical connection between the valve and the switch. If mechanical connection is good replace shutoff switch.
Choke is not functioning correctly in Test 17 – Check Choke Assembly.Replace the choke assembly.
No AC OutputBAD REPAIR OR REPLACE COMPONENT, BAD REPAIR OR REPLACE WIREREPLACE INVERTER MODULE
No DC Output (iX Units Only)REPLACE INVERTER MODULE
Flex Power/Mode Feature is Not RespondingREPLACE INVERTER MODULE, REPLACE SWITCH, TEST FLEX POWER/MODE SWITCH
LED Display INOPReplace LED MODULE
Engine won't start.1. No fuel in tank. 2. Fuel valve turned off. 3. Defective spark plug. 4. Plugged fuel filter. 5. Defective or stuck engine stop switch1. Add fuel to tank. 2. Turn fuel valve on. 3. Replace spark plug. 4. Replace fuel filter. 5. Replace engine start switch
Engine starts, then shuts down.1. Low fuel level. 2. Fuel tank vent closed. 3. Incorrect engine oil level. 4. Contaminated fuel. 5. Defective low oil level switch. 6. Defective ignition coil1. Add fuel to tank. 2. Open fuel tank vent. 3. Check engine oil level, add or drain as needed. 4. Replace fuel filter. 5. Replace Low Oil Level switch. 6. Replace ignition coil
Engine starts, then runs rough.*1. Choke is stuck or left on. 2. Dirty or clogged air filter. 3. Defective or dirty spark plug. 4. Dirty fuel filter. 5. Defective EcoMode switch1. Turn choke off. 2. Clean or replace the air filter element. 3. Replace spark plug. 4. Replace fuel and fuel filter. 5. Replace EcoMode switch
No AC output.1. Generator is overloaded (OVERLOAD LED is on and READY LED is flashing, See control Panel Identification section). 2. AC voltage is low (OVERLOAD LED is on and READY LED is flashing, See control Panel Identification section). 3. Inverter module is overheated (OVERLOAD LED is on and READY LED is flashing, See control Panel Identification section). 4. Short circuit in electrical device (OVERLOAD LED is on and READY LED is flashing, See control Panel Identification section). 5. Defective inverter assembly1. Shut down generator to reset module. Reduce loads and restart generator. 2. Verify that the choke is OFF. 3. Verify service door is ON. Let cool for 15 minutes and restart generator. 4. Verify condition of any extension cords and all items being powered. 5. Replace inverter assembly
No DC output.1. DC circuit breaker is open. 2. Defective DC circuit breaker. 3. Defective rectifier1. Reset DC circuit breaker. 2. Replace DC circuit breaker. 3. Replace rectifier
Fuel leaks from drain hoses.1. Fuel system over primed (flooded). 2. Carburetor drain in bowl is not closed1. Let generator sit 15 minutes before restarting. 2. Turn valve clockwise to close

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Cross-brand guides for these symptoms

Common questions

Generac iX 2000: Overload Light is On — what causes it?

Documented causes: IS THE LOAD CONNECTED?. See the table for the matching fixes.

Generac iX 2000: Engine Hunts / Erratic Idle or Will Not Come Up to Speed — what causes it?

Documented causes: IS THE UNIT PRODUCING AC POWER? IS THE ENGINE RUNNING ERRATICALLY?. See the table for the matching fixes.

Generac iX 2000: Compression is poor — what causes it?

Documented causes: Loose cylinder head bolts. Failed cylinder head gasket. Burned valves or valve seats. Insufficient valve clearance. Warped cylinder head. Warped valve stem. Worn or broken piston ring(s). Worn or damaged cylinder bore. Broken connecting rod. Worn valve seats or valves.. See the table for the matching fixes.