SymptomCauseRemedy
No AC OutputBAD REPAIR OR REPLACE COMPONENT, BAD REPAIR OR REPLACE WIREREPLACE INVERTER MODULE
No DC Output (iX Units Only)REPLACE INVERTER MODULE
Overload Light Is OnDISCONNECT LOAD, RESTART ENGINE AND CHECK AC OUTPUT AGAIN. (iX Units) DISCONNECT LOAD, PRESS AND HOLD RESET BUTTON, THEN RELEASE. IF OVERLOAD LIGHT GOES OUT, LOAD IS TO MUCH FOR THE UNIT. (iQ2000)
Engine Will Not Pull StartNOTHING FOUND, BAD REPLACE COMPONENT, VISUALLY INSPECT FOR OBSTRUCTIONS THAT WOULD CAUSE BINDING OF THE RECOIL ONCE INSTALLED
Flex Power/Mode Feature is Not RespondingREPLACE INVERTER MODULE, REPLACE SWITCH, TEST FLEX POWER/MODE SWITCH
Engine Will Not StartREPLACE CARBURETOR, REPLACE FUEL PUMP, REPAIR OR REPLACE STATOR, REPLACE IGNITION WINDING
Engine Hunts / Erratic Idle or Will Not Come Up to SpeedProblem 7
Unit Shuts Down for Low OilProblem 8
LED Display INOPReplace LED MODULE

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Cross-brand guides for these symptoms

Common questions

Generac GP3000i: No AC Output — what causes it?

Documented causes: BAD REPAIR OR REPLACE COMPONENT, BAD REPAIR OR REPLACE WIRE. See the table for the matching fixes.