Kohler — Generator Storage Procedure

Maintenance · Generator set

From a Kohler operator's manual covering: 10/13/15ERG, 10ERG, 13ERG, 15ERG, TP-6334. Check it applies to your exact model before use.

Applies to: Kohler 10ERG, Kohler 13ERG, Kohler 15ERG

Before you start

  • Run the generator set once a month whenever possible.

Procedure

  1. Start and run the generator set until it reaches operating temperature or about 15 minutes.
  2. Stop the generator set.
  3. Change the oil and oil filter.
  4. Drain the fuel completely from the fuel tank.
  5. Check the engine coolant protection; use antifreeze capable of withstanding the lowest possible temperatures.
  6. Keep spark plugs in their holes or seal spark plug holes with suitable threaded metal plugs.
  7. Clean the exterior and spread a light film of oil or silicon spray over exposed surfaces.
  8. Seal the air inlet, exhaust pipe, and fuel tank cap with tape.
  9. Disconnect and remove the battery; store in a warm, dry location. Recharge the battery once a month.
  10. Select a well-ventilated (not humid or dusty) location to store the generator.
  11. Cover the entire unit with a dust cover.

Full service-parts list: Kohler 10ERG →, Kohler 13ERG →, Kohler 15ERG →

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.