Before you start

  • Before removing the pressure cap, stop the generator set and allow it to cool. Then loosen the pressure cap to relieve pressure.

Procedure

  1. Remove the pressure cap, open the radiator's coolant drain valve and let the system drain completely.
  2. Drain, clean, and flush the coolant overflow bottle.
  3. Flush the system with clean water.
  4. Close the radiator's coolant drain valve.
  5. Fill the system with the recommended coolant.
  6. Replace the pressure cap.