Home›Repair guides›Kohler›Diesel Mechanical Governor Frequency Adjustment

Kohler — Diesel Mechanical Governor Frequency Adjustment

Adjustments · Fuel Pump High Speed Screw

From a Kohler service manual covering: CSG-649, Cummins 4B, Cummins 6B, Ford CSG-649, Ford LSG-423, Ford LSG-875, LSG-423, lsg-875. Check it applies to your exact model before use.

Applies to: Ford CSG-649, Cummins/Onan LSG-423, Cummins/Onan lsg-875

Procedure

  1. Start the generator set, observe the frequency meter.
  2. Loosen the fuel pump high speed screw locknut to make the adjustments.
  3. To increase or decrease the frequency (at no load), rotate the screw clockwise or counterclockwise respectively.
  4. Tighten the locknut.
  5. Loaded droop frequency may alternately be adjusted to the operating frequency at full load.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Ford CSG-649 →, Cummins/Onan lsg-875 →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.