Home›Repair guides›Kohler›Battery Installation and Connection

Kohler — Battery Installation and Connection

Installation · engine starting battery

From a Kohler service manual covering: 10REOZD, 15REOZD, 20REOZD. Check it applies to your exact model before use.

Applies to: Kohler 10REOZD, Kohler 15REOZD, Kohler 20REOZD

Before you start

  • Battery gases. Explosion can cause severe injury or death. Do not smoke or permit flames or sparks near a battery.
  • Remove the negative (--) lead first when disconnecting; reconnect the negative (--) lead last.

Procedure

  1. Verify that the generator set master control switch is in the OFF/RESET position.
  2. Ensure that the starting battery is fully charged before placing the battery in service.
  3. Clean the battery posts and/or adapters if necessary.
  4. Install battery post adapters, if needed.
  5. Place the battery on the battery rack on the skid.
  6. Connect the red battery cable to the positive (+) battery terminal.
  7. Connect the black battery cable to the negative (--) battery terminal.
  8. Place the boots over the battery terminals.
  9. Plug the battery heater and battery charger, if equipped, into the 120 VAC power supply.

Full service-parts list: Kohler 10REOZD →, Kohler 15REOZD →, Kohler 20REOZD →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →