Home›Repair guides›Kohler›Storage Procedure

Kohler 14RCA / 20RCA — Storage Procedure

Maintenance · Generator set

For the Kohler 14RCA / 20RCA, from the Kohler operator's manual.

Applies to: Kohler 14RCA, Kohler 20RCA, Kohler CH 740 engine, Kohler CH1000 engine

Procedure

  1. Run generator ~15 minutes to reach operating temperature, then stop
  2. Drain engine oil while warm; refill crankcase; run briefly to distribute; stop
  3. Start generator, shut off gas supply, run until engine stops, press OFF
  4. Remove spark plugs; pour one tablespoon of oil into each plug hole; reinstall plugs, ground leads; crank engine 2-3 revolutions
  5. Clean exterior; seal engine openings with nonabsorbent tape; mask electrical contact areas; oil unpainted metal surfaces
  6. Press OFF; disconnect battery negative lead first; clean battery; store in warm dry location
  7. Connect battery to float/equalize charger or charge monthly with trickle charger

Full service-parts list: Kohler 14RCA →, Kohler 20RCA →

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →