Home›Repair guides›Kohler›Battery Cleaning

Kohler 14RCA / 20RCA — Battery Cleaning

Maintenance

For the Kohler 14RCA / 20RCA, from the Kohler operator's manual.

Applies to: Kohler 14RCA, Kohler 20RCA, Kohler CH 740 engine, Kohler CH1000 engine

Before you start

  • Battery acid can cause severe injury or blindness. Wear protective goggles and clothing.

Parts for this job

Part numbers from the service-parts lists for Kohler 14RCA, Kohler 20RCA. Verify against your serial number before ordering; some links are affiliate links.

Procedure

  1. Disconnect battery cables, negative lead first.
  2. Scrub battery terminals with a wire brush.
  3. Clean battery and cables with baking soda and water solution.
  4. Flush with clean water and wipe with dry, lint-free cloth.
  5. Reconnect battery cables, negative lead last.
  6. Coat terminals with petroleum jelly, silicone grease, or nonconductive grease.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler 14RCA →, Kohler 20RCA →

Source: Kohler operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Kohler repair guides →