Before you start

  • Do not clean, wash or reuse the secondary element

Procedure

  1. Remove wing nut, canister cover and primary filter assembly.
  2. Thoroughly clean all dirt from inside canister.
  3. Squeeze dust unloader valve to remove dust.
  4. Replace secondary element only if green dot disappeared.
  5. Install new primary element and tighten wing nut securely.
  6. Depress air restriction indicator reset button if equipped.

Specs & values

  • Restriction indicator/retaining nut: 14 Nm (10 lb-ft)
  • Maximum air intake restriction 25 in. H2O (625 mm)