Honda — Battery Charging
Maintenance
From a Honda service manual covering: EB4000, EB5000, EB6500, EM4000SX, EM5000SXK3, EM6500SXK2. Check it applies to your exact model before use.
Applies to: Honda EB4000, Honda EB6500, Honda EM4000SX, Honda GX270T2 engine, Honda GX390T2 engine
Before you start
- Battery gives off explosive gases; keep sparks, flames, and cigarettes away.
- Battery contains sulfuric acid; contact with skin or eyes may cause severe burns.
Procedure
- Turn combination switch OFF.
- Remove battery.
- Check battery for damage.
- Leave battery for 30 minutes.
- Measure battery voltage with digital multimeter.
- If below 12.4 V, charge battery.
- Connect charger positive to positive, negative to negative.
- Leave for 30 minutes.
- Measure voltage; if below 12.7 V, charge.
- If still below 12.7 V, replace battery.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- VOLTAGE (20°C/68°F): Fully charged: Above 12.8 V; Under charged: Below 12.4 V
- CHARGING CURRENT/TIME: Standard: 1.1 A/ 5 – 10 h; Quick: 5.5 A/ 1 h
Full service-parts list: Honda EB6500 →, Honda EM4000SX →, Honda GX390T2 engine →
Source: Honda service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.