Generac — Testing the Genistor

Testing & diagnosis · Genistor (frequency converter)

From a Generac service manual covering: GN-190, GN-220, NP-30G, NP-40G. Check it applies to your exact model before use.

Applies to: Generac NP-30G, Generac GN-190 / GN-220 engine, Generac GN-220 engine

Before you start

  • DO NOT attempt to test the Genistor until ALL leads have been disconnected. It MUST be completely disconnected from the circuit or all test results are invalid.

Procedure

  1. Disconnect all wires from the Genistor before testing.
  2. Set a VOM to a resistance scale allowing 20-60 ohms to be read and zero the meter.
  3. Connect one VOM lead to COM and the other to terminals G1, G2, G3 and G4 one at a time; each should read 20-60 ohms.
  4. Set the VOM to Rx1; connect across COM terminal and the center screw; should read continuity.
  5. Check continuity across each AC1, AC2, SL1 and SL2 screw to its terminal.
  6. Set VOM to Rx10,000 or Rx1K; there should be no continuity (infinity) between any of the screws.
  7. Replace the Genistor if it fails any of these tests.

Tools required

  • VOM (volt-ohm-milliammeter) Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • COM to G1/G2/G3/G4 = 20-60 ohms

Full service-parts list: Generac NP-30G →

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.