Generac — Testing the Fuel Lockoff Solenoid

Testing & diagnosis · Gaseous fuel lockoff solenoid

From a Generac service manual covering: GN-190, GN-220, NP-30G, NP-40G. Check it applies to your exact model before use.

Applies to: Generac NP-30G, Generac GN-190 / GN-220 engine, Generac GN-220 engine

Procedure

  1. Set a VOM to read battery voltage (12 VDC).
  2. Connect the VOM test leads across Wire 14 (Red) at the solenoid and a clean frame ground.
  3. Set the fuel primer switch on the generator panel to its ON position.
  4. The meter should indicate battery voltage and the solenoid should energize open.
  5. If battery voltage is indicated but the solenoid does not energize, replace the lockoff solenoid.
  6. If battery voltage is not indicated, a problem exists in the DC control system.