Home›Repair guides›Generac›Remove From Service (storage)

Generac — Remove From Service (storage)

Maintenance · generator

From a Generac owner's manual covering: GH-426, GT-999, GTH-530. Check it applies to your exact model before use.

Applies to: Generac GH-426 engine, Generac GTH-530 engine, Generac GT-999 engine

Procedure

  1. Start the engine and let it warm up.
  2. Close the fuel shutoff valve in the fuel supply line and allow the engine to stop.
  3. Set the generator MLCB (generator disconnect) to OFF (OPEN).
  4. Turn off the utility power to the transfer switch.
  5. Remove battery charger AC input T1/Neutral cable at controller.
  6. Remove the 7.5 amp fuse from the control panel.
  7. Disconnect the battery cables, negative cable first.
  8. Drain the oil completely while engine is still warm, then refill the crankcase with oil.
  9. Attach a tag to the engine indicating the viscosity and classification of the new oil.
  10. Remove spark plug(s) and spray a fogging agent into the threaded openings; reinstall and tighten to spec.
  11. Remove the battery and store in a cool, dry room on a wooden board.
  12. Clean and wipe down the entire generator.

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.