Home›Repair guides›Generac›Reconfiguring the Fuel System (7 kW, 410cc Engine)

Generac — Reconfiguring the Fuel System (7 kW, 410cc Engine)

Installation · Demand regulator / fuel system

From a Generac service manual — check it applies to your exact model before use.

Applies to: Generac GH-410 engine, Generac GT-530 engine, Generac GT-530 engine, Generac GT-990 engine

Before you start

  • Use an approved pipe sealant or joint compound on all threaded fittings to reduce the possibility of leakage.

Procedure

  1. Turn off the main gas supply (if connected).
  2. Open the roof and remove the door.
  3. Remove the battery (if installed).
  4. Disconnect Wire 0 and Wire 14 from the gas solenoid on top of the demand regulator.
  5. Remove the carburetor fuel hose from the outlet port of the demand regulator.
  6. Remove the demand regulator by removing the fastener that retains the regulator mounting bracket.
  7. Remove the square headed steel pipe plug from outlet port #1 and the brass hose barb fitting from outlet port #2.
  8. Refit the brass hose barb fitting to outlet port #1 and the square headed steel pipe plug to outlet port #2.
  9. Reverse procedure Steps 1-6 to reinstall demand regulator.
  10. Take the plastic plug supplied with the generator and press it into the 3/4" hole on the bottom of the air cleaner base.
  11. Reverse the procedure to convert back to natural gas.
  12. Check for gas leakage at the pipe plug, hose connection and fittings.

Specs & values

  • Propane supply pressure to the fuel inlet must be 10 to 12 inches of water column (0.36 to 0.43 psi).

Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.