Home›Repair guides›Generac›Removal From Service (Storage)

Generac PRIMEPACT 70 — Removal From Service (Storage)

Maintenance · Generator

For the Generac PRIMEPACT 70, from the Generac owner's manual.

Applies to: Generac PRIMEPACT 70, Generac GN-480 engine

Before you start

  • Never store the battery on any concrete or earthen floor.

Procedure

  1. Start the engine and let it warm up.
  2. Close the fuel shutoff valve in the fuel supply line and allow the unit to shut down.
  3. While still warm, drain the oil completely and refill with SAE 10W-30 API "For Service SF".
  4. Attach a tag to the engine indicating the oil viscosity and classification.
  5. Remove the spark plug and pour two or three tablespoons of clean engine oil into the opening; reinstall and tighten.
  6. Remove the battery and store it in a cool, dry room on a wooden board.
  7. Clean and wipe the entire generator.

Full service-parts list: Generac PRIMEPACT 70 →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.