Generac NP-66G — Servicing the Engine Air Cleaner
Maintenance
For the Generac NP-66G, from the Generac owner's manual.
Applies to: Generac NP-66G, Generac GN-480 engine
Before you start
- Do NOT use a forceful spray of water to clean the generator
Parts for this job
Part numbers from the service-parts list for Generac NP-66G. Verify against your serial number before ordering; some links are affiliate links.
Procedure
- Turn knob counterclockwise to loosen.
- Remove cover, foam pre-cleaner and paper filter.
- Wash foam pre-cleaner in liquid detergent and water.
- Wrap in cloth and squeeze dry; saturate in engine oil and squeeze out excess.
- Install foam pre-cleaner into cover, followed by paper filter with tabs in slots.
- Insert bottom locking tag of cover into slot and install cover.
Specs & values
- Clean and re-oil foam pre-cleaner every 3 months or 25 hours
- Replace paper filter yearly or every 100 hours
Full service-parts list: Generac NP-66G →
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.