Home›Repair guides›Generac›Out of Service Protection (Storage)

Generac NP-66G — Out of Service Protection (Storage)

Maintenance · Generator

For the Generac NP-66G, from the Generac owner's manual.

Applies to: Generac NP-66G, Generac GN-480 engine

Before you start

  • Never store the battery on any concrete or wooden floor

Procedure

  1. Start engine and let it warm up.
  2. Close fuel shutoff valve and let engine run out of gas.
  3. While engine still warm, drain oil completely and refill with SAE 10W-30 API 'For Service SF' oil.
  4. Attach tag indicating oil viscosity and classification.
  5. Remove spark plugs, pour two or three tablespoons clean engine oil into openings, crank several times, reinstall plugs.
  6. Remove battery and store in cool, dry room on a wooden board.
  7. Clean and wipe the entire generator.

Specs & values

  • Use if out of service longer than 30 days

Full service-parts list: Generac NP-66G →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.