Generac NP-30G — Out of service protection (storage)
Maintenance · Generator
For the Generac NP-30G, from the Generac owner's manual.
Applies to: Generac NP-30G, Generac GN-220 engine
Before you start
- Never store the battery on any concrete or dirt floor.
Procedure
- Start the engine and let it warm up.
- While still warm, drain the oil completely, then refill crankcase with recommended oil.
- Attach a tag to the engine indicating the viscosity and classification of the oil.
- Remove spark plug and add about 1/2 ounce (15ml) of clean, fresh engine oil into the spark plug threaded opening.
- Crank engine several times to distribute oil, then install and tighten spark plug.
- Remove the battery and store it in a cool, dry room on a wooden board.
- Clean and wipe the entire generator.
Specs & values
- Prepare for storage when out of service longer than 30 days.
Full service-parts list: Generac NP-30G →
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.