Generac MDE330 — Checking Generator Drive Plate Torque
Maintenance
For the Generac MDE330, from the Generac owner's manual.
Applies to: Generac MDE330, Perkins 1706J-E93TAG2 engine
Before you start
- Accidental Start-up. Disconnect the negative battery cable first.
Procedure
- Disconnect battery.
- Remove generator fan guard.
- Tighten each drive plate bolt to 44 ft-lb (56.9 Nm).
- Install generator fan guard.
- Connect battery.
Specs & values
- 44 ft-lb (56.9 Nm)
Full service-parts list: Generac MDE330 →
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.