Generac MCG1000MT2 — Parallel Setup and Operation
Installation · Paralleling CAN connection
For the Generac MCG1000MT2, from the Generac owner's manual.
Applies to: Generac MCG1000MT2, Mitsubishi S12H-Y2PTAW-1 engine
Before you start
- Contact Generac Mobile Products Technical Service to verify the units to be used in parallel are appropriate for the planned load.
Procedure
- Verify each unit operates properly and set up auto (remote) starting on each unit.
- Remove receptacle covers from the CAN receptacles.
- Using the provided link cable, connect a CAN receptacle on the first unit to a CAN receptacle on the next unit.
- Insert the provided 120 ohm resistor plug into the unused CAN receptacles on both units.
- To parallel more than two units, chain link cables to the next unit; insert 120 ohm resistor plugs into unused CAN receptacles on first and last units.
Tools required
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Up to 32 generators
- 120 ohm resistor plugs
Full service-parts list: Generac MCG1000MT2 →
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.