Generac MCG1000MT2 — Auto (Remote) Starting of the Unit
Operation · Remote start circuit
For the Generac MCG1000MT2, from the Generac owner's manual.
Applies to: Generac MCG1000MT2, Mitsubishi S12H-Y2PTAW-1 engine
Before you start
- Follow all safety warnings on isolating the generator with a transfer switch if used as a standby power supply.
Procedure
- Perform a manual start of the unit at least once to verify that the engine is operating correctly.
- Connect the remote start wires to terminals #12 and #34 on TB4.
- Remove the jumper wire from the terminal block and the engine will stop; reconnect remote start switch wires.
- Confirm the unit is in Auto Mode; the LCD window should show "Auto Mode" at the top of the screen.
- The unit is now ready for remote starting.
Tools required
- Jumper wire minimum 16 gauge Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Remote start terminals #12 and #34 on TB4
- TB4 located behind the main circuit breaker panel, on the left side
Full service-parts list: Generac MCG1000MT2 →
Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.