For the Generac 9734 / NP-66LPG, from the Generac owner's manual.

Applies to: Generac 9734, Generac NP-66LPG, Generac GN-480 engine

Before you start

  • Never store the battery on any concrete or wooden floor

Procedure

  1. Start the engine and let it warm up.
  2. Close the fuel shutoff valve in the fuel supply line and let the engine run out of fuel.
  3. While the engine is warm, drain oil completely and refill crankcase with SAE 10W-30 'For Service SF' oil.
  4. Attach a tag to the engine indicating oil viscosity and classification.
  5. Remove spark plugs, pour two or three tablespoons clean engine oil into openings, crank several times, then install and tighten spark plugs.
  6. Remove the battery and store in a cool, dry room on a wooden board.
  7. Clean and wipe the entire generator.

Specs & values

Full service-parts list: Generac 9734 →, Generac NP-66LPG →

Source: Generac owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.