From a Fischer Panda owner's manual covering: 12000NE-15000NE, Panda 12.000NE, Panda 14.000NE, Panda 15.000NE. Check it applies to your exact model before use.
Browse Fischer Panda generators & specs →
Procedure
- Switch main power switch OFF.
- Press and hold failure bypass switch; fuel pump must be audible.
- After 3-4 minutes, open ventilation screw at fuel solenoid valve while keeping button pressed.
- Let fuel run out until no air bubbles; close screw.
- Release failure bypass switch.
- Start generator with start button.
- If it does not start, loosen one injection line nut, retry start, then retighten.
Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.