Home›Repair guides›Fischer Panda›Ventilating the Fuel System

Fischer Panda — Ventilating the Fuel System

Maintenance

From a Fischer Panda owner's manual covering: 12000NE-15000NE, Panda 12.000NE, Panda 14.000NE, Panda 15.000NE. Check it applies to your exact model before use.

Browse Fischer Panda generators & specs →

Procedure

  1. Switch main power switch OFF.
  2. Press and hold failure bypass switch; fuel pump must be audible.
  3. After 3-4 minutes, open ventilation screw at fuel solenoid valve while keeping button pressed.
  4. Let fuel run out until no air bubbles; close screw.
  5. Release failure bypass switch.
  6. Start generator with start button.
  7. If it does not start, loosen one injection line nut, retry start, then retighten.

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.