Before you start

  • Remove battery main switch

Procedure

  1. Open capsule; remove cable ties.
  2. Disconnect electric supply line of thermoswitch.
  3. Loosen thermoswitch with 22 mm wrench.
  4. Check label for correct item before installing new thermoswitch.
  5. Reinstall in reverse order.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Fischer Panda Panda 10000i PMS →, Fischer Panda Panda 8000i PMS generator →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.