Fischer Panda Panda 4200 / Panda 4500 — First filling and ventilation of cooling circuit

Maintenance · cooling system

For the Fischer Panda Panda 4200 / Panda 4500, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 4500, Fischer Panda Panda_4000s, Farymann 18W430 engine

Before you start

  • Risk of scalding; do not open vent screw while generator runs.

Procedure

  1. Fill external cooling water expansion tank with coolant to max marking; open its cap.
  2. Open vent screw at internal cooling water pump until bubble-free coolant escapes; close.
  3. Open vent screw at thermostat housing until air-free water comes out; close.
  4. Start generator without load for about 10 seconds; stop.
  5. Repeat steps 1-4 until no air comes out; fill to max and close expansion tank.
  6. Repeat ventilation 10 operating hours after first start-up if necessary.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Maximum fill level = max marking
  • Expansion tank pressure relief valve 500 mbar

Full service-parts list: Fischer Panda Panda 4500 →, Fischer Panda Panda_4000s →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.