Home›Repair guides›Fischer Panda›Adjustment of the normal speed limitation

Fischer Panda Panda 4200 / Panda 4500 — Adjustment of the normal speed limitation

Adjustments · VCS actuator

For the Fischer Panda Panda 4200 / Panda 4500, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 4500, Fischer Panda Panda_4000s, Farymann 18W430 engine

Before you start

  • Reconnect actuator plug after adjustment.

Procedure

  1. Disconnect plug at actuator electrical supply line.
  2. Unclamp countering nuts with two SW 14 wrenches.
  3. Connect voltmeter with range to 300 V AC to AC outlet; ensure no load.
  4. Start generator.
  5. Turn actuator spindle manually until voltmeter reads 220 V.
  6. Screw both nuts tight.
  7. Check lower voltage is limited to min. 220 V without load.
  8. For upper limitation, proceed as before and tighten countering nuts at max. 270 V without load.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Lower limit 220 V
  • Upper limit 270 V

Full service-parts list: Fischer Panda Panda 4500 →, Fischer Panda Panda_4000s →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.