Home›Repair guides›Fischer Panda›Adjustment of the maximum upper speed

Fischer Panda Panda 4200 / Panda 4500 — Adjustment of the maximum upper speed

Adjustments · VCS actuator

For the Fischer Panda Panda 4200 / Panda 4500, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 4500, Fischer Panda Panda_4000s, Farymann 18W430 engine

Before you start

  • Adjustment should not be changed; warranty may expire.

Procedure

  1. Disconnect plug at actuator electrical supply line.
  2. Unclamp countering nut at limitation screw with SW 10 wrench.
  3. Connect voltmeter with range to 300 V AC to AC outlet in electrical cabinet.
  4. Ensure no electrical load is connected.
  5. Start generator.
  6. Turn actuator spindle manually until voltmeter reads 270 V.
  7. Turn limit stop screw tight against limit stop point at speed regulator lever.
  8. Secure limit stop screw with countering nut.
  9. Check voltage is limited to max. 270 V without load.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Maximum voltage 270 V without load

Full service-parts list: Fischer Panda Panda 4500 →, Fischer Panda Panda_4000s →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Fischer Panda repair guides →