Fischer Panda Panda 19i / Panda 19i PMS — First filling and venting internal cooling water circuit

Maintenance · Cooling system

For the Fischer Panda Panda 19i / Panda 19i PMS, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 19i, Kubota D902 engine

Before you start

  • Risk of scalding; hot coolant can escape.
  • Never open vent screw while generator is running.

Procedure

  1. Fill external expansion tank with coolant to max marking; open cover.
  2. Open venting screw at internal cooling water pump until bubble-free coolant escapes; close.
  3. Open venting screw at thermostat housing; close when air-free water comes out.
  4. Start generator unloaded for approx. 10 seconds and switch off.
  5. Repeat steps 1-4 until no more air comes out; fill expansion tank to max.
  6. Re-ventilate 10 operating hours after first start-up if necessary.

Specs & values

  • Expansion tank pressure relief valve: 500 mbar
  • Re-ventilate after 10 operating hours

Full service-parts list: Fischer Panda Panda 19i →, Kubota D902 engine →