Home›Repair guides›Fischer Panda›Ventilation of coolant circuit / freshwater

Fischer Panda Panda 15 mini PMS Digital — Ventilation of coolant circuit / freshwater

Maintenance · Cooling system

For the Fischer Panda Panda 15 mini PMS Digital, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 15 mini PMS Digital, Kubota D902 engine

Before you start

  • The ventilation screw above the cooling water pump casing may not be opened while the generator is running.

Procedure

  1. Switch off generator before opening vent points.
  2. Ensure external expansion tank is connected and at sufficient height.
  3. Open vent screw above cooling water pump casing if present.
  4. Open vent screw on thermostat casing.
  5. Pour cooling water into filling necks or external expansion tank.
  6. When level no longer drops, close filler cover and vent screws; start generator.
  7. Run generator approx. 60 seconds; switch off.
  8. Refill cooling water via compensation tank.
  9. Repeat procedure 1-5 times.
  10. If no change, run 5 minutes and repeat de-aeration two to three times.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Fischer Panda Panda 15 mini PMS Digital →, Kubota D902 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.