Home›Repair guides›Fischer Panda›Insulation test

Fischer Panda Panda 15 mini PMS Digital — Insulation test

Testing & diagnosis · Electrical system

For the Fischer Panda Panda 15 mini PMS Digital, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 15 mini PMS Digital, Kubota D902 engine

Procedure

  1. Switch off all on-board electrical devices.
  2. Start the generator.
  3. Measure AC voltage with voltmeter between generator housing and AC-Control box.
  4. Measure AC voltage between generator housing and ground.
  5. Measured voltage must not exceed 50 mV.
  6. Check safety systems and leakage current relay if installed.
  7. Ensure all electrical devices are connected to common ground.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Measured voltage must not exceed 50 mV

Full service-parts list: Fischer Panda Panda 15 mini PMS Digital →, Kubota D902 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.