Fischer Panda Panda 15 mini PMS Digital — Insulation test
Testing & diagnosis · Electrical system
For the Fischer Panda Panda 15 mini PMS Digital, from the Fischer Panda owner's manual.
Applies to: Fischer Panda Panda 15 mini PMS Digital, Kubota D902 engine
Procedure
- Switch off all on-board electrical devices.
- Start the generator.
- Measure AC voltage with voltmeter between generator housing and AC-Control box.
- Measure AC voltage between generator housing and ground.
- Measured voltage must not exceed 50 mV.
- Check safety systems and leakage current relay if installed.
- Ensure all electrical devices are connected to common ground.
Tools required
- voltmeter Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Measured voltage must not exceed 50 mV
Full service-parts list: Fischer Panda Panda 15 mini PMS Digital →, Kubota D902 engine →
Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.