Home›Repair guides›Fischer Panda›Daily routine checks before starting

Fischer Panda Panda 15 mini PMS Digital — Daily routine checks before starting

Operation · Generator

For the Fischer Panda Panda 15 mini PMS Digital, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 15 mini PMS Digital, Kubota D902 engine

Before you start

  • Check oil level daily before initially running the generator.

Procedure

  1. Check oil level; top up to MAX if below mark.
  2. Check cooling water level in external compensation tank.
  3. Open sea cock for cooling water intake.
  4. Check raw water filter.
  5. Check hose connections and clamps for leaks.
  6. Check electrical lead terminal contacts are firm.
  7. Check motor and generator mounting screws are tight.
  8. Switch off all load before starting.
  9. Check automatic controls and oil pressure.

Full service-parts list: Fischer Panda Panda 15 mini PMS Digital →, Kubota D902 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.