Home›Repair guides›Fischer Panda›Check and discharge capacitors

Fischer Panda Panda 15 mini PMS Digital — Check and discharge capacitors

Maintenance · AC control box capacitors

For the Fischer Panda Panda 15 mini PMS Digital, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 15 mini PMS Digital, Kubota D902 engine

Before you start

  • Charged capacitors can be lethal. Do not touch capacitor contacts.

Procedure

  1. Never check capacitors while generator motor is running.
  2. Disconnect terminal lead wires using insulated pliers or screwdriver.
  3. Discharge capacitor terminals by bridging with discharge reactor.
  4. For three-phase capacitors discharge between L1-L2, L2-L3, L1-L3.
  5. Switch multimeter to capacitor measuring; connect probes to terminals.
  6. Measure capacity of each capacitor.
  7. Check all capacitors in electrical cabinet.

Tools required

  • multimeter with capacitor measuring Amazon
  • discharge reactor 5-10 kOhm Amazon
  • insulated pliers/screwdriver Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Discharge reactor 5-10 kOhm

Full service-parts list: Fischer Panda Panda 15 mini PMS Digital →, Kubota D902 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.