Home›Repair guides›Fischer Panda›First filling and ventilation of internal cooling water circuit

Fischer Panda Panda 10000i PMS / Panda 8000i PMS — First filling and ventilation of internal cooling water circuit

Maintenance · cooling system

For the Fischer Panda Panda 10000i PMS / Panda 8000i PMS, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 10000i PMS, Kubota Z482 engine, Kubota Z602 engine

Before you start

  • Risk of scalding; hot cooling water can leak
  • Check circulation; air bubbles can cause overheating

Procedure

  1. Fill external cooling water expansion tank with coolant to max mark.
  2. Open cover of external expansion tank temporarily; all other closures closed.
  3. Open venting screw at thermostat housing.
  4. Close vent screw when air-free water comes out; check expansion tank level.
  5. Start generator and run approx. 10 seconds without load, then switch off.
  6. Repeat steps 1-4 until no more air comes out.
  7. Fill expansion tank to max mark and close.
  8. Repeat ventilation process 10 operating hours after first start-up and if necessary.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Expansion tank pressure relief valve 500 mbar
  • Coolant mixture good for at least -15 °C

Full service-parts list: Fischer Panda Panda 10000i PMS →, Kubota Z482 engine →, Kubota Z602 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.