Fischer Panda Panda 10000i PMS / Panda 8000i PMS — Activating/deactivating autostart
Operation · iControl2
For the Fischer Panda Panda 10000i PMS / Panda 8000i PMS, from the Fischer Panda owner's manual.
Applies to: Fischer Panda Panda 10000i PMS, Kubota Z482 engine, Kubota Z602 engine
Before you start
- Automatic start-up: generator can start automatically
- Autostart remains active after on/off until disabled
Procedure
- Select Autostart in set-up menu and confirm with Start/Stop.
- Choose Enable or Disable with cursor buttons.
- Confirm selection with Start/Stop; message shows Autostart enabled/disabled.
- Setting is saved to EEPROM and controller shuts down.
- After restart, status field AUTOSTART indicates active; STANDBY indicates deactivated.
Full service-parts list: Fischer Panda Panda 10000i PMS →, Kubota Z482 engine →, Kubota Z602 engine →
Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.