Home›Repair guides›Cummins/Onan›Verify the Safety Input

Cummins/Onan — Verify the Safety Input

Testing & diagnosis · EC-30 safety input

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan HDKA, Cummins/Onan HDKB, Cummins/Onan HDKC

Before you start

  • If the safety input is not verified by day 30, AUTO GEN is disabled.

Procedure

  1. Press the AUTO GEN key; the EC-30 requests verification of the SAFETY (IGNITION, PARK or BRAKE) input.
  2. Turn on or off the appropriate safety input signal (ignition, transmission position, park brake or trailer brake).
  3. Press ENTER only if the genset is in a safe location for automatic operation.

Specs & values

  • Safety Input must change from off to on, or on to off, to reset the 30 day timer

Full service-parts list: Cummins/Onan HDKA →, Cummins/Onan HDKB →, Cummins/Onan HDKC →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Cummins/Onan repair guides →